Scissor Truss & Vaulted Ceiling Calculator

Enter two top and lower reference pitches from a supplier drawing and a common clear span. Compare the width at a desired finished ceiling height while checking a separate limit on the roof reference peak.

Vault and roof reference lines

Compare vaulted ceiling profiles

Both profiles meet the entered clearance and roof limits.
Profile A · Clear width
12 ft
17 ft roof peak · Within entered limits
Profile B · Clear width
14.4 ft
18 ft roof peak · Within entered limits
Scaled ceiling and roof section

Profile A has 12 ft of width at the entered clear height of 10 ft.

  • Roof reference
  • Finished ceiling
  • Probe
  • Target clear height
  • Roof limit

At 6 ft from left, finished ceiling is 10 ft and the roof reference is 13 ft.

Shared span and constraints
Profile A dimensions
Profile B dimensions
Review profile coordinates and CSV
Clear ranges and both reference profiles
ProfileClear fromClear throughClear width marginPeak limit marginMinimum reference separation
Profile A6 ft18 ft0 ft1 ft1 ft
Profile B4.8 ft19.2 ft2.4 ft0 ft1 ft

How to use this calculator

  1. Enter the clear span, required height and width, and the maximum roof reference height from the same floor datum.
  2. For each profile enter both pitches, lower reference elevation, vertical heel separation and finish drop.
  3. Switch between the scaled sections and check finished ceiling height at the probe station.
  4. Review the clearance and roof limit margins, then export the exact coordinates and measurements.

The Formula

The mathematical logic powering this calculation is:

Measure horizontal position x from the left end of the clear span S. Because both halves are symmetric, the run from the nearer side is d = min(x, S − x). Convert each entered rise-per-12 pitch into its slope by dividing by 12.

The lower reference elevation is bearing reference height plus lower slope × d. Finished ceiling height is lower reference height minus the entered vertical finish drop. The top reference elevation is bearing reference height plus vertical heel separation plus top slope × d. Keep those datums consistent across your drawings. The minimum signed separation between reference lines occurs at an end or the crest.

The entire span meets the clear-height test if the target is at or below the finished bearing height. For an intermediate target on a rising profile, the left crossing is (target − finished bearing height) divided by the lower slope. The right crossing is its reflection across midspan. At the crest target the crossing is a single point and width is zero. A target above the ceiling crest leaves the clear range unavailable.

A profile meets the worksheet's constraints when the clear width reaches the entered width, the roof reference peak is within its limit, and the top reference never falls below the lower reference. Exact equality at each entered boundary is included. Probe readings are calculated at the entered station separately from the centered clear-width calculation.

Lengths are feet with up to four decimal places. Clear span and target width are 0.0001–300 ft, target headroom and roof limit 0–300 ft. The probe is within the span. Bearing height is 0–100 ft, heel separation and finish drop 0–20 ft, and each pitch 0–48 rise per 12. The vertical finish drop cannot exceed the lower reference height at bearing. Use this symmetric reference geometry for space comparison. Supplier drawings and structural review address actual member depths, joints, loads, code, supports, and installation. The CSV preserves exact fractions.

Worked Example

If you input:

  • Clear span: 24 ft with 10 ft clear height across a required 12 ft
  • Roof height limit: 18 ft
  • Profiles: Lower 4:12 and roof 8:12 for A, lower 5:12 and roof 9:12 for B, with an 8 ft bearing reference and 1 ft heel on both

Result:

A has 12 ft clear width at 10 ft height and a 17 ft roof reference peak. B has 14.4 ft clear width and reaches the 18 ft roof limit. Dropping A's finish by 0.001 ft reduces its clear width to 11.994 ft.

Frequently Asked Questions

Which ceiling dimension is used for clearance?

The tool uses the lower reference elevation minus an entered vertical finish drop. Use actual finished offsets from your drawing.

Why do two profiles with the same roof peak have different usable widths?

The width depends on the lower pitch, lower bearing elevation and any finish drop. The top reference pitch determines the roof peak separately.

What happens at the exact crest height?

A rising ceiling reaches that height at one location. The clear width there is zero. A flat ceiling reaches its own height along the entire span.

Does separation between the lines specify an allowable truss?

It describes the geometry from your values. Structural design requires the member, connector, load and bearing information on the approved drawing.

Similar Calculators