EIRP & Feed-Line Budget Planner
Compare two transmit-side antenna setups at entered cable lengths. Follow power from the transmitter through cable and other fixed losses to directional EIRP. A shared length chart shows how the two feed lines change the power budget and where each meets the same reference.
Compare EIRP through two feed lines
Trace transmitter power to directional EIRP and see how cable length changes the result against one entered reference.
Shared comparison
Set your own comparison value. Use a chart length that includes both entered cable lengths.
Transmitter, feed line and antenna
Use antenna gain in the direction being compared and cable loss at the intended frequency. Enter additional losses separately.
Estimated EIRP at entered lengths
Shared EIRP reference · 30 dBm
Chain A 32 dBm. 2 dB above reference. Chain B 28 dBm. 2 dB below reference.
Chain A
32 dBm
1.58489319 W
2 dB above reference
Transmitter27 dBm
−2 dB cable
After cable25 dBm
−1 dB other
Antenna input24 dBm
+8 dBi gain
Directional EIRP32 dBm
Transmitter power at reference 25 dBm
Chain B
28 dBm
0.63095734 W
2 dB below reference
Transmitter25 dBm
−4 dB cable
After cable21 dBm
−2 dB other
Antenna input19 dBm
+9 dBi gain
Directional EIRP28 dBm
Transmitter power at reference 27 dBm
EIRP across cable length
Cable length changes along the horizontal axis. Transmitter power, directional gain and loss rates stay fixed.
Cable length (m)
- Chain A · solid
- Chain B · dashed
- Reference
Chain A
Reference intersection · 80 m
Chain B
Reference intersection · 25 m
Power ledger and export
The ledger lists the entered lengths and any reference intersections inside the chart. The CSV also includes the loss and gain steps for both chains.
Open cable-length ledger
| Cable length | Chain A EIRP | A vs reference | Chain B EIRP | B vs reference |
|---|---|---|---|---|
| 0 m | 34 dBm | above | 32 dBm | above |
| 25 m | 32.75 dBm | above | 30 dBm | exact |
| 40 m | 32 dBm | above | 28.8 dBm | below |
| 50 m | 31.5 dBm | above | 28 dBm | below |
| 80 m | 30 dBm | exact | 25.6 dBm | below |
| 100 m | 29 dBm | below | 24 dBm | below |
Open CSV text
How to use this calculator
- Set a shared EIRP reference and a chart end length that fits both cable runs.
- Enter transmitter power, antenna gain in the chosen direction, cable length and cable attenuation rate for each setup.
- Enter remaining fixed losses such as connector or adapter loss if the cable rate excludes them.
- Read each power ledger, compare the shared profiles and export the setup values and intersection rows.
The Formula
The mathematical logic powering this calculation is:
Use antenna gain in dBi in the direction of interest and use power, gain and losses stated on a comparable operating basis for each chain. The worksheet assumes one fixed rate of cable attenuation per 100 m for each option. Use a rate documented or measured for the intended cable and frequency. Cable loss in dB equals rate × length ÷ 100. Other losses in dB are added separately so any loss already in the cable rate is counted once. Antenna input in dBm equals transmitter power minus cable and other losses. EIRP in dBm equals that antenna input plus gain in dBi. A dBm value references 1 mW, so EIRP in watts equals 10 raised to (EIRP dBm − 30) ÷ 10.
The signed result relative to the entered reference equals EIRP minus reference, in dB. The transmitter power corresponding to the same reference at the entered losses and gain is reference plus the two losses minus gain. This is an algebraic counterpart at the same operating point. The reference is your own comparison value and the app makes no jurisdictional, exposure, range or reception determination.
The chart varies cable length only. It holds transmitter power, cable attenuation per unit length, other losses and directional gain fixed. If attenuation is positive, the reference intersects the line at 100 × (transmitter power + gain − other losses − reference) ÷ rate, in meters, when this value is nonnegative. The ledger identifies intersections beyond the chart separately. At zero cable attenuation the EIRP remains constant over all lengths. The chart begins at 0 m and includes both entered lengths and every in-view reference intersection.
Tx and reference accept −120 to 120 dBm, gain −60 to 60 dBi, fixed losses 0 to 100 dB, and cable attenuation 0 to 100 dB per 100 m. Cable length accepts 0 to 1,000 m and the shared chart extent accepts 0.001 to 1,000 m. Entries accept up to three decimals. Reference comparisons use exact arithmetic on entered decimals. Estimated watts and displayed intersection lengths are rounded for display.Worked Example
If you input:
- Reference: 30 dBm (1 W). Chart extends to 100 m.
- Chain A: 27 dBm transmitter, 8 dBi gain, 40 m of cable at 5 dB per 100 m, 1 dB of other losses.
- Chain B: 25 dBm transmitter, 9 dBi gain, 50 m of cable at 8 dB per 100 m, 2 dB of other losses.
Result:
A reaches 32 dBm (about 1.585 W), 2 dB above reference. B reaches 28 dBm (about 0.631 W), 2 dB below. With the other values fixed, their profiles meet the reference at 80 m and 25 m respectively.
Frequently Asked Questions
What is the difference between EIRP and antenna input power?
Antenna input is the power reaching the feed point after losses. EIRP describes the equivalent power a hypothetical isotropic radiator would use to produce the same intensity in the specified direction. It includes gain in that direction.
Which antenna gain should I enter?
Use gain relative to an isotropic antenna, in dBi, in the direction of interest. Use the same direction and relevant operating frequency for each option when comparing setups.
Why does the 0 m chart result still include loss?
At zero cable length the per-length cable loss is zero. Any other fixed loss you entered is still included.
How do I read an intersection outside the chart?
The report has solved a nonnegative modeled length greater than the plotted extent. Increasing the chart end may bring it into view if the intersection lies within the worksheet's 1,000 m range.
What does the transmitter power at reference mean?
It is the transmitter power corresponding to the entered reference with the same cable length, losses and antenna gain. It is a mathematical result and can fall outside the editable input range or equipment capability.
Similar Calculators
Antenna Length & Dipole Cut Planner
Compare two half-wave dipole wire lengths from the ARRL estimate or a measured reference. Check per-arm cut allowance and wire stock across your frequency band.
Passive Filter Bode Plot & Load Planner
Plot gain and phase for two loaded RC or series RLC filters. Compare cutoff shifts, half-power frequencies and source-referenced gain at your test frequency.
Speaker Impedance & Amplifier Load Planner
Calculate speaker ohms for series and parallel layouts. Compare nominal loads with complex impedance at measured frequencies, phase and ideal RMS power.
Wavelength & Phase Path Calculator
Calculate frequency and wavelength in up to four media. Compare path delay, wrapped phase and the shared frequency range for entered lengths.
Noise Figure Calculator & RF Cascade
Calculate cascaded noise figure and receiver sensitivity from stage gain and noise figure. Compare stage order, noise floors and input-referred contributions.
Decibel to Watt Calculator & Duty Profile Audit
Convert measured dBm intervals to watts, energy and linear mean power. Compare the time at or above a chosen threshold with an entered budget.