Noise Figure Calculator & RF Cascade

Paste up to eight stages from a receiver chain. Compare two chains at one bandwidth, source temperature and required SNR. Inspect how early gain or loss changes each later stage’s contribution.

RF receiver noise

Compare noise figure across receiver chains

Chain B has the lower noise figure.
Edit stages and measurement conditions

Paste label, gain in dB, and noise figure in dB, in signal order. Enter passive as the noise figure for a loss at 290 K.

Chain A

4.10164004 dB

Cascade noise figure at 290 K reference

Linear noise factor
2.57136663 ×
Net gain
17 dB
Input noise
-116.863247 dBm
Output noise
-99.8632472 dBm
Added noise temperature
455.696323 K
Sensitivity threshold
-104.863247 dBm

Chain B

1.23315213 dB

Cascade noise figure at 290 K reference

Linear noise factor
1.32835824 ×
Net gain
17 dB
Input noise
-119.731735 dBm
Output noise
-102.731735 dBm
Added noise temperature
95.2238882 K
Sensitivity threshold
-107.731735 dBm

Cumulative noise figure

Points show the cumulative figure after each stage. Gold marks the inspected stage.

Cumulative noise figure following each stageSelected stage 1. Chain A Cable, cumulative noise figure 3 dB, share of added noise 63.3373711%. Chain B LNA, cumulative noise figure 1 dB, share of added noise 78.8545509%.02.5503Stage numberNoise figure (dB)
  • Chain A
  • Chain B

Stage 1

A · Cable · 288.626071 K added · 63.3373711% of added noise

B · LNA · 75.0883694 K added · 78.8545509% of added noise

Review stage calculations and export CSV
Stage noise and input-referred contributions
ChainStageGain dBNF dBAdded at input KShare %
ACable-33288.62607163.3373711
ALNA201149.82099432.877376
AReceiver0617.24925813.78525286
BLNA20175.088369478.8545509
BCable-332.886260713.0310259
BReceiver0617.249258118.1144232

Use comparable gain and noise figures for one linear path at the frequency of interest. The model uses an equivalent noise bandwidth and the same input reference plane for each chain.

How to use this calculator

  1. Paste the stage label, gain in dB, and noise figure in dB for each stage in signal order. Enter passive in place of NF for a passive loss at 290 K.
  2. Enter equivalent noise bandwidth, source temperature and required SNR. Add chain B to compare both designs under the same conditions.
  3. Compare cumulative noise figure and input-referred stage contributions. Move the keyboard-accessible stage slider to inspect the stages in both chains.
  4. Open the ledger and download gain, noise, stage contributions and sensitivity calculations as CSV.

The Formula

The mathematical logic powering this calculation is:

Convert power gain and noise figure to linear form, Gᵢ = 10^(gainᵢ/10) and Fᵢ = 10^(NFᵢ/10). Stage i adds an input-referred excess factor of (Fᵢ − 1)/(G₁ × … × Gᵢ₋₁), with gain product 1 ahead of the first stage. Friis cascade noise factor is 1 plus the sum of these excess factors. Convert to dB using 10 log₁₀(F). Stage noise shares divide each excess factor by their sum. When the sum is zero, all shares display zero.

The reference source temperature for noise figure is T₀ = 290 K. A passive loss at this physical temperature has noise figure equal to its loss in dB. Enter passive in that stage’s NF column to use this relation. For other components, including passive parts at other temperatures, enter the applicable noise figure.

The equivalent added input temperature is Tₑ = T₀(F − 1). For source temperature Tₛ and equivalent noise bandwidth B, input noise is kB(Tₛ + Tₑ) watts. The SI Boltzmann constant k is 1.380649 × 10⁻²³ J/K. Convert watts to dBm with 10 log₁₀(1000 × watts). Add net gain in dB for output noise and add required SNR in dB to input noise for the input sensitivity threshold.

Use compatible stage power gains and noise figures for a single-path linear chain at the frequency of interest. Account for mismatch, frequency response, and mixer/image effects in the input data or an appropriate model. Enter 1–8 stages per chain. Gain spans −80 to 80 dB, numeric NF 0–80 dB, bandwidth positive through 10 billion Hz, source temperature positive through 5,000 K and required SNR from −100 to 100 dB. Inputs allow up to six decimals.

Worked Example

If you input:

  • Chain A: 3 dB cable loss, 20 dB LNA with 1 dB NF, 6 dB NF receiver
  • Chain B: Same stages with the LNA first
  • Conditions: 200,000 Hz, 290 K source, 12 dB required SNR

Result:

Both chains have 17 dB net gain. Putting the LNA first lowers cascade noise figure from about 4.10 to 1.23 dB and shifts the input sensitivity threshold from about −104.86 to −107.73 dBm.

Frequently Asked Questions

Why can the same stages have different noise figures in a different order?

Each stage’s added noise is divided by the preceding power gain when referred to the input. Gain early in the chain reduces the input-referred contribution of later components.

How do I enter a cable or attenuator?

Enter its loss as a negative gain. For a passive loss at 290 K, enter passive for the noise figure. A 3 dB loss then contributes 3 dB noise figure as a standalone stage.

How are noise factor and noise figure related?

Noise factor F is linear. Noise figure NF in decibels is 10 log₁₀(F), and the equivalent added noise temperature is 290(F − 1) kelvin.

What bandwidth belongs in a receiver sensitivity calculation?

Use the equivalent noise bandwidth of the receive path associated with the SNR criterion you enter.

Why does source temperature change sensitivity without changing noise figure?

The noise figure convention uses a fixed 290 K reference. Input noise and sensitivity include the actual source temperature you enter.

Similar Calculators