Noise Figure Calculator & RF Cascade
Paste up to eight stages from a receiver chain. Compare two chains at one bandwidth, source temperature and required SNR. Inspect how early gain or loss changes each later stage’s contribution.
Compare noise figure across receiver chains
Compare the same gain stages in different orders and see their impact on input noise and sensitivity.
Edit stages and measurement conditions
Paste label, gain in dB, and noise figure in dB, in signal order. Enter passive as the noise figure for a loss at 290 K.
Chain A
4.10164004 dB
Cascade noise figure at 290 K reference
- Linear noise factor
- 2.57136663 ×
- Net gain
- 17 dB
- Input noise
- -116.863247 dBm
- Output noise
- -99.8632472 dBm
- Added noise temperature
- 455.696323 K
- Sensitivity threshold
- -104.863247 dBm
Chain B
1.23315213 dB
Cascade noise figure at 290 K reference
- Linear noise factor
- 1.32835824 ×
- Net gain
- 17 dB
- Input noise
- -119.731735 dBm
- Output noise
- -102.731735 dBm
- Added noise temperature
- 95.2238882 K
- Sensitivity threshold
- -107.731735 dBm
Cumulative noise figure
Points show the cumulative figure after each stage. Gold marks the inspected stage.
- Chain A
- Chain B
Stage 1
A · Cable · 288.626071 K added · 63.3373711% of added noise
B · LNA · 75.0883694 K added · 78.8545509% of added noise
Review stage calculations and export CSV
| Chain | Stage | Gain dB | NF dB | Added at input K | Share % |
|---|---|---|---|---|---|
| A | Cable | -3 | 3 | 288.626071 | 63.3373711 |
| A | LNA | 20 | 1 | 149.820994 | 32.877376 |
| A | Receiver | 0 | 6 | 17.2492581 | 3.78525286 |
| B | LNA | 20 | 1 | 75.0883694 | 78.8545509 |
| B | Cable | -3 | 3 | 2.88626071 | 3.0310259 |
| B | Receiver | 0 | 6 | 17.2492581 | 18.1144232 |
Use comparable gain and noise figures for one linear path at the frequency of interest. The model uses an equivalent noise bandwidth and the same input reference plane for each chain.
How to use this calculator
- Paste the stage label, gain in dB, and noise figure in dB for each stage in signal order. Enter passive in place of NF for a passive loss at 290 K.
- Enter equivalent noise bandwidth, source temperature and required SNR. Add chain B to compare both designs under the same conditions.
- Compare cumulative noise figure and input-referred stage contributions. Move the keyboard-accessible stage slider to inspect the stages in both chains.
- Open the ledger and download gain, noise, stage contributions and sensitivity calculations as CSV.
The Formula
The mathematical logic powering this calculation is:
Convert power gain and noise figure to linear form, Gᵢ = 10^(gainᵢ/10) and Fᵢ = 10^(NFᵢ/10). Stage i adds an input-referred excess factor of (Fᵢ − 1)/(G₁ × … × Gᵢ₋₁), with gain product 1 ahead of the first stage. Friis cascade noise factor is 1 plus the sum of these excess factors. Convert to dB using 10 log₁₀(F). Stage noise shares divide each excess factor by their sum. When the sum is zero, all shares display zero.
The reference source temperature for noise figure is T₀ = 290 K. A passive loss at this physical temperature has noise figure equal to its loss in dB. Enter passive in that stage’s NF column to use this relation. For other components, including passive parts at other temperatures, enter the applicable noise figure.
The equivalent added input temperature is Tₑ = T₀(F − 1). For source temperature Tₛ and equivalent noise bandwidth B, input noise is kB(Tₛ + Tₑ) watts. The SI Boltzmann constant k is 1.380649 × 10⁻²³ J/K. Convert watts to dBm with 10 log₁₀(1000 × watts). Add net gain in dB for output noise and add required SNR in dB to input noise for the input sensitivity threshold.
Use compatible stage power gains and noise figures for a single-path linear chain at the frequency of interest. Account for mismatch, frequency response, and mixer/image effects in the input data or an appropriate model. Enter 1–8 stages per chain. Gain spans −80 to 80 dB, numeric NF 0–80 dB, bandwidth positive through 10 billion Hz, source temperature positive through 5,000 K and required SNR from −100 to 100 dB. Inputs allow up to six decimals.Worked Example
If you input:
- Chain A: 3 dB cable loss, 20 dB LNA with 1 dB NF, 6 dB NF receiver
- Chain B: Same stages with the LNA first
- Conditions: 200,000 Hz, 290 K source, 12 dB required SNR
Result:
Both chains have 17 dB net gain. Putting the LNA first lowers cascade noise figure from about 4.10 to 1.23 dB and shifts the input sensitivity threshold from about −104.86 to −107.73 dBm.
Frequently Asked Questions
Why can the same stages have different noise figures in a different order?
Each stage’s added noise is divided by the preceding power gain when referred to the input. Gain early in the chain reduces the input-referred contribution of later components.
How do I enter a cable or attenuator?
Enter its loss as a negative gain. For a passive loss at 290 K, enter passive for the noise figure. A 3 dB loss then contributes 3 dB noise figure as a standalone stage.
How are noise factor and noise figure related?
Noise factor F is linear. Noise figure NF in decibels is 10 log₁₀(F), and the equivalent added noise temperature is 290(F − 1) kelvin.
What bandwidth belongs in a receiver sensitivity calculation?
Use the equivalent noise bandwidth of the receive path associated with the SNR criterion you enter.
Why does source temperature change sensitivity without changing noise figure?
The noise figure convention uses a fixed 290 K reference. Input noise and sensitivity include the actual source temperature you enter.
Similar Calculators
EIRP & Feed-Line Budget Planner
Calculate EIRP in dBm and watts for two transmitter, cable and antenna chains. Compare directional gain, feed-line loss and the cable lengths that reach an entered reference.
Passive Filter Bode Plot & Load Planner
Plot gain and phase for two loaded RC or series RLC filters. Compare cutoff shifts, half-power frequencies and source-referenced gain at your test frequency.
Wavelength & Phase Path Calculator
Calculate frequency and wavelength in up to four media. Compare path delay, wrapped phase and the shared frequency range for entered lengths.
