Dies per Wafer Calculator & Grid Layout

Compare two uniform rectangular placements on a measured circular wafer. Use separate horizontal and vertical scribe streets, shift each grid within its repeat pitch, and count only the dies whose full corners fit inside the usable circle.

Wafer layout worksheet

Count whole dies on a wafer

Grid A fits 3 more whole dies.
Edit the wafer and grid placements

Enter usable die dimensions excluding scribe streets. Streets are fixed to the wafer axes. Offsets are percentages of each grid's pitch from the wafer center.

Grid A
Grid B

Grid A

103 whole dies

Pitch 14.12 × 9.2 mm · Unrotated

Meets gross target · +1 margin

95.275 expected tested good

Grid B

100 whole dies

Pitch 9.12 × 14.2 mm · 90° rotation

Below gross target · -2 margin

92.5 expected tested good

Plot whole dies on the wafer

Each rectangle is one whole die. The amber outline marks the selected row.

Grid A die placements and edge exclusion103 whole dies. Usable diameter 144 mm. 15 occupied rows. Selected row 0 has 9 whole dies.144 mm usable diameter

Row 0 · 9 whole dies

Center y 0 mm · die centers x -56.48 to 56.48 mm.

Review occupied rows and export CSV
Grid A · occupied rows · exact mm
RowCenter yFirst center xLast center xWhole dies
-7-64.4001
-6-55.2-28.2428.245
-5-46-42.3642.367
-4-36.8-42.3642.367
-3-27.6-56.4856.489
-2-18.4-56.4856.489
-1-9.2-56.4856.489
00-56.4856.489
19.2-56.4856.489
218.4-56.4856.489
327.6-56.4856.489
436.8-42.3642.367
546-42.3642.367
655.2-28.2428.245
764.4001

Counts use the entered rectangular dies and circular usable area. Use your wafer map for notches, alignment sites, test structures and production exclusions.

How to use this calculator

  1. Enter the wafer diameter, edge-exclusion width, die sides and the two wafer-axis scribe street widths.
  2. Enter the rotation and phase for each grid. Compare the exact count with your whole-die target.
  3. Switch the displayed grid on the wafer map and browse occupied rows.
  4. Optionally enter an observed tested-good percentage from the process you want to model.
  5. Download the row coordinates, pitches and whole-die counts for both grids.

The Formula

The mathematical logic powering this calculation is:

The usable radius is half the entered wafer diameter minus the edge exclusion. A die's dimensions cover the rectangle between streets. The horizontal pitch equals its wafer-axis width plus the horizontal street. Vertical pitch is computed the same way. Rotating a plan by 90° exchanges die width and height and keeps the two street dimensions fixed to the wafer axes.

For each axis, use the entered phase as a percentage of that plan's pitch. The repeating center coordinates are offset + integer index × pitch. A phase of 0% places one center at the wafer axis. A 50% phase places it half a pitch from the axis. Use phases from 0 to 99.9%.

For a die centered at (x,y) with half-width a and half-height b, the farthest corner has squared distance (|x| + a)² + (|y| + b)². Count the die when this is no greater than the squared usable radius. On each row, take the integer square root of R² − (|y| + b)² in exact coordinate units. Subtract a to obtain the largest permitted absolute x coordinate. The whole-die centers fill a contiguous run between the first and last grid positions that satisfy the limit. Sum all row counts. Exact boundary contact is included.

The map displays individual dies for layouts through 460 whole dies. Larger layouts show row spans and may sample the rows for legibility. Inspect occupied rows with the controls. The table shows up to 60 rows from the selected grid, and the CSV preserves all occupied rows for both grids. The entered target compares gross counts. If you enter a known tested-good percentage, the additional estimate is gross count × that percentage. This expectation can be fractional.

Dimensions use millimeters with at most three decimal places. Diameter supports 1–450 mm. The exclusion must be less than the wafer radius. Die sides support 0.1–300 mm. Each street supports 0–10 mm. Gross target supports 0–20 million, and optional tested yield supports 0–100% with one decimal. Geometry uses exact scaled integers including the phase and half-dimensions. The worksheet evaluates the two supplied grids. Account separately for notches, flats, alignment targets, shot boundaries, mixed layouts, local defects and process qualifications.

Worked Example

If you input:

  • Wafer and die: 150 mm wafer, 3 mm edge exclusion, die 14 × 9 mm.
  • Scribe widths: 0.12 mm horizontally and 0.2 mm vertically.
  • Compared grids: Centered unrotated A and 90° B with a half-pitch shift in both axes.

Result:

Grid A fits 103 whole dies and exceeds the 102-die target by one. Grid B fits 100. At entered tested yield 92.5%, the corresponding expectations are 95.275 and 92.5 good dies.

Frequently Asked Questions

What is the difference between a die dimension and the pitch?

A die dimension spans the finished rectangle. Pitch is the distance between neighboring die centers and equals the die dimension plus its street.

Can a die count when a corner just touches the usable boundary?

Yes. The worksheet uses a closed circular boundary. Enter any additional manufacturing clearance as part of the wafer edge exclusion.

Why does rotating a die change a layout?

Rotation swaps the rectangular die dimensions. Unequal streets or phases can reposition the row centers and change which corners fit.

Why does a dense wafer map show horizontal bars?

Each bar spans from the first whole die to the last on that row. The smaller clearances remain in the exact pitches and row coordinates in the export.

Does the calculator find the highest possible die count?

It counts the two selected placements. More phases, different field arrangements or reserved areas would require a broader comparison.

Are expected good dies the same as geometrically complete dies?

Gross counts use geometry. The tested-good estimate applies the entered percentage to that count, so it can be fractional.

Similar Calculators