Deck Post Spacing Calculator & Excluded Station Layout

Equal spacing may put a post at an unavailable station. Compare the actual station interval and excluded zones to find a complete center layout from one fixed end to the other. See which marks are blocked, reachable or part of the chosen layout.

Deck post layout

Check post spacing around excluded stations

Fixed run and documented limits
Exclusion A
Exclusion B
4 posts fit the entered run and spacing limits.
Complete layout
4 posts
3 gaps meet the entered limits
Farthest reachable station
18 ft
10 total stations including both fixed centers

Review the post center run

Candidate center stations18 ft between fixed ends
Reachable deck post stations and exclusionsThe station run shows open or filled circles, exclusion crosses, a dashed inspection cursor and the selected connecting segments.0 ft18 ft
  • ● Chosen or reachable
  • ○ Unreachable
  • × Excluded

6 ft · Chosen center · 6 ft from its preceding center

Review the stations and exact CSV
Candidate and fixed post centers
Station (ft)StatePreceding gap (ft)
0Chosen center—
2Unreachable—
4Reachable4
6Chosen center6
8Excluded—
10Reachable6
12Chosen center6
14Reachable4
16Reachable6
18Chosen center6

How to use this calculator

  1. Enter the distance between the two required post centers and the allowable candidate station interval from your layout.
  2. Enter the already documented minimum and maximum center gaps for the straight run.
  3. Enable an exclusion for each interval of unavailable centers. Enter its start and end distances from the first fixed center.
  4. Check whether a complete path reaches the far end. Inspect the selected gaps, marked exclusions and exact worksheet before discussing the layout.

The Formula

The mathematical logic powering this calculation is:

Set the first fixed center at 0 and the second at the entered distance L. Candidate interior centers are positive whole multiples of the entered station interval less than L. The second end stays at L even when it falls between grid points. Each optional exclusion blocks all stations in the closed interval [start,end]. Include any needed clearance in the entered limits. A fixed end within an exclusion is a separate blocked outcome.
A path can advance between two unblocked stations only when their center-to-center distance is at least the entered minimum and at most the maximum. At each station, compare all allowed incoming gaps from reachable predecessors. Keep the path using the fewest centers, then the smallest sum of squared gaps in integer thousandths of a foot. Equal scores at a station use the earlier predecessor. For paths with the same count and run length, minimizing squared gaps also minimizes their variance. The computed layout is optimal over the entered discrete grid. A mark can be reachable from the first end without reaching the second.
Enter one run length and station interval of 0.1–300 ft. Minimum and maximum permitted gaps range from 0.001–300 ft. Support is capped at 320 interior stations to keep the editable calculation bounded. Lengths accept up to three decimals. Both endpoints and approved spacing limits come from the documented project. This worksheet checks only station positions. Beam spans, structural loads, required connections, footing size, utility confirmation, and approvals are separate.

Worked Example

If you input:

  • Fixed center separation: 18 ft
  • Candidate station interval: 2 ft
  • Permitted gaps: 4–6 ft
  • Excluded centers: 7.5 to 8.5 ft
  • Second exclusion: Off

Result:

Four posts at 0, 6, 12 and 18 ft meet all three gaps exactly at 6 ft. When the maximum becomes 5.999 ft, the station at 4 ft is reachable, but the blocked 8 ft mark and other gaps prevent a complete path.

Frequently Asked Questions

Can an endpoint be off the candidate grid?

Yes. The second end always represents the exact supplied distance. Only proposed interior centers must lie on the grid.

Does the minimum count include both endpoints?

Yes. The two fixed centers are included in the count and are required for a complete path.

Can an exclusion start and end at the same point?

Yes. A point-only exclusion blocks a station exactly at that point. Both boundaries of an interval are included.

Why do some reachable points appear in a failed plan?

Some stations can be reached from the first end while the remaining gaps make the final station unreachable. The worksheet marks the farthest reachable station separately.

Does the result approve deck post spacing?

It checks only the supplied geometric limits and candidate stations. Get the spacing and support criteria from the actual project documents.

Similar Calculators