Capillary Shear Rate & Viscosity Curve Calculator
Analyze positive flow and pressure drop readings from the same circular capillary. Calculate wall stress from the net pressure drop and compare the apparent shear rate with Weissenberg–Rabinowitsch corrections from one global log-log fit or neighboring samples.
Compare measured and corrected shear behavior
See how apparent viscosity changes when the correction follows one fitted slope or nearby readings.
A single fitted slope of 0.5 is applied to all observations.
- Apparent
- Corrected
Review stress, slopes and CSV
| Flow (mL/s) | Net drop (kPa) | Wall stress (Pa) | Apparent η (Pa·s) | Global η (Pa·s) | Neighboring η (Pa·s) | Neighboring slope |
|---|---|---|---|---|---|---|
| 1 | 10 | 300 | 0.40715 | 0.32572 | 0.32572 | 0.5 |
| 4 | 20 | 600 | 0.203575 | 0.16286 | 0.16286 | 0.5 |
| 16 | 40 | 1,200 | 0.101788 | 0.08143 | 0.08143 | 0.5 |
| 64 | 80 | 2,400 | 0.050894 | 0.040715 | 0.040715 | 0.5 |
How to use this calculator
- Enter the internal diameter and bore length from the same capillary used for the readings.
- Paste flow in mL/s, measured pressure drop in kPa and documented end loss in kPa as three numeric columns per row.
- Compare the global and neighboring correction methods on the viscosity chart and select a measured flow to review both estimates.
- Open the ledger or download the complete worksheet with apparent, global and local results.
The Formula
The mathematical logic powering this calculation is:
Use one circular capillary with radius R equal to half its internal diameter and a measured bore length L. Convert millimetres to metres, mL/s to m³/s, and kPa to Pa. Net pressure drop Δp equals entered total drop minus entered end loss. Enter zero end loss when the provided data already isolates the pressure drop along the developed bore. Wall stress τ = ΔpR/(2L). The apparent shear rate γ̇ₐ = 4Q/(πR³), and apparent viscosity is τ/γ̇ₐ.
The log-log slope n is the change in ln(τ) per unit change in ln(γ̇ₐ). The global method fits all ordered readings by unweighted least squares. The neighboring method uses the secant through the nearest reading on each side, or the first or last observed pair at an endpoint. It uses the same samples for estimating the slope and for drawing the chart, with no extrapolation or smoothing.
For a positive slope, the corrected shear rate is γ̇ₐ × (3n + 1)/(4n). The inferred viscosity is the same wall stress divided by the corrected rate. A nonpositive slope leaves that correction unavailable. At n = 1 the correction factor is one. The global and neighboring methods can give different answers when the response bends on logarithmic axes.
The interpretation assumes fully developed, steady flow in a circular bore, with comparable sample and temperature conditions across readings and negligible wall slip. The worksheet subtracts entered end loss rather than estimating a Bagley correction from multiple dies. It does not infer wall slip, test conditions, material limits or process settings. Inspect irregular measured data and the suitability of the correction before using results.
Inputs accept at most six decimal places. Diameter 0.001–200 mm, length 0.001–2,000 mm, 3–24 unique positive flows 0.000001–100,000 mL/s and pressure 0.000001–1,000,000 kPa. End losses must be nonnegative and smaller than their corresponding total. Pressure difference preserves the entered decimal precision; logs, geometric constants and fits are numerical approximations. CSV exports up to twelve significant digits.Worked Example
If you input:
- Bore: 2.4 mm internal diameter and 20 mm length
- Flow: 1, 4, 16 and 64 mL/s
- Measured drop: 12, 22, 42 and 82 kPa, each with 2 kPa entered end loss
Result:
The slope is 0.5 throughout and the correction factor is 1.25. At 1 mL/s apparent shear is 736.8284 s⁻¹, corrected shear 921.0356 s⁻¹ and corrected viscosity 0.3257 Pa·s.
Frequently Asked Questions
Why do the correction methods diverge?
The global slope summarizes the whole trace. A neighboring secant responds to changes around each measured point, so a curved or irregular trace can shift the local result.
Can I enter pressure data that has already been corrected?
Yes. Enter the pressure drop along the measured bore and use zero for end loss. Subtract each end loss only once.
Why is a corrected viscosity missing?
A flat or decreasing fitted stress with increasing apparent shear gives a nonpositive slope. The worksheet retains the apparent reading and leaves the correction unavailable.
What happens for a Newtonian test result?
With positive net pressure drop proportional to flow, the slope is one and the apparent and corrected rates agree.
Similar Calculators
Pipe Pressure Drop Calculator
Compare pipe pressure loss across inside diameters. Calculate Darcy friction, fitting losses, velocity and Reynolds number with explicit transition limits.
Volumetric Flow Rate & Collection Audit Calculator
Calculate liquid flow from timed volume or mass collections. Compare measured bounds, duration-weighted flow, meter readings and target fill time.
Linear Regression Calculator
Fit a least-squares line, inspect scatter and residual plots, and calculate Student-t confidence and prediction intervals. Paste paired data and export the full ledger.
Orifice Plate Flow & Differential Pressure Calculator
Compare two calibrated orifice plates. Estimate liquid flow from differential pressure, or check whether a target fits the calibrated range and gauge span.