Air Leak Rate Calculator & Pressure Decay Audit

Use two recorded absolute-pressure and temperature pairs, connected volume and elapsed time. Compare signed inventory change against the pressure-only estimate at the same entered reference conditions.

Dry air

Compare measured pressure decay with temperature

Use recorded absolute pressure and temperature at both endpoints. See how cooling can mimic a pressure-only loss and how measurement bounds affect the result.

Enter the volume reference conditions

Equivalent litres depend on the reporting pressure and temperature. Enter the same basis for both records.

Record A measurements

Use a fixed connected volume and previously recorded dry-air readings. Enter the same bound for both endpoint readings, or zero for exact modeled readings.

Record B measurements

Use a fixed connected volume and previously recorded dry-air readings. Enter the same bound for both endpoint readings, or zero for exact modeled readings.

Compare recorded air inventory change

Rates use 100 kPa absolute and 20 °C as the reference.

Record A
2.9315 L/min
Loss across entered bounds
Record B
0 L/min
Bounds include zero net change

Pressure-only and temperature-corrected change

Positive values indicate modeled loss. Negative values indicate modeled gain. Both records share a scale in reference litres per minute.

Record A

Temperature-corrected
2.9315 L/min
Entered bounds
2.738 to 3.125 L/min
Pressure-only estimate
2.9315 L/min

Record B

Temperature-corrected
0 L/min
Entered bounds
−0.2006 to 0.2006 L/min
Pressure-only estimate
2.9315 L/min

Export the pressure-decay audit

The CSV includes the entered end readings, both rate methods and the exact bound fractions.

Download pressure-decay CSV
View selectable pressure-decay CSV

How to use this calculator

  1. Enter reference absolute pressure and temperature for the equivalent litres you want to report.
  2. Enter each record’s connected dry-air volume, elapsed minutes, and measured start and end absolute pressures and temperatures.
  3. Enter bounded absolute pressure and temperature deviations, or use zero to model exact entered values. The same bound applies at both endpoints.
  4. Compare temperature-corrected change, the pressure-only estimate and the result across the entered bounds. Export the exact rate fractions and assumptions as CSV.

The Formula

The mathematical logic powering this calculation is:

Use dry ideal air in a fixed connected volume with recorded start and end readings. Convert Celsius to Kelvin by adding 273.15. Divide each absolute pressure by its absolute temperature. The difference of these two ratios is proportional to signed inventory change.

Equivalent reference litres per minute = volume × reference Kelvin ÷ reference absolute pressure × (start absolute pressure ÷ start Kelvin − end absolute pressure ÷ end Kelvin) ÷ elapsed minutes. For the pressure-only comparison, use the start Kelvin in both terms. Positive is modeled inventory loss, negative is modeled gain, and zero means the modeled inventory is unchanged.

At each measured endpoint, apply the same entered absolute pressure bound and the same entered temperature bound. To bound the lowest change, combine low start pressure with high start temperature and high end pressure with low end temperature. Reverse the extremes for the upper result. The bounds assume each input can vary independently within the entered interval and exclude a statistical confidence level.

The result is an average rate over the observed interval, on the specified volume-reporting basis. It does not estimate flow at another operating pressure, attribute the change to one source, or judge equipment acceptability. Use already recorded data for the same fixed volume and dry-air basis within each record.

Worked Example

If you input:

  • Volume and elapsed time: 120 L over 10 minutes in both records
  • Start and end pressure: 500 kPa to 475 kPa absolute in both records
  • Record A temperatures: 26.85 °C at both endpoints
  • Record B temperatures: 26.85 °C to 11.85 °C
  • Reference volume conditions: 100 kPa absolute and 20 °C
  • Measurement bounds: ±0.5 kPa and ±0.2 °C

Result:

The pressure-only estimate is 2.9315 L/min for both records. The corrected change stays 2.9315 L/min for Record A and becomes exactly 0 L/min for Record B. Record B’s entered bounds include zero net change.

Frequently Asked Questions

How can a receiver’s pressure drop without a decrease in modeled air inventory?

Cooling at a fixed volume lowers pressure for the same dry-air inventory. The corrected calculation compares absolute pressure divided by Kelvin at both endpoints.

Can I enter my gauge pressure directly against the form labels?

The model requires absolute pressure at both endpoints. If your instrument reports gauge pressure, use the appropriate documented absolute-pressure conversion first.

What does a negative corrected air change mean?

The measured endpoint ratios imply an increase in modeled inventory over the period. Measurement deviations, an unmatched operating record or actual inflow can affect the interpretation.

Why does the worksheet ask for reference pressure and temperature?

The same amount of air occupies different volumes at different pressure and temperature. Enter the reporting basis used in the comparison.

Do the entered bounds represent a confidence interval for the leak rate?

The bounds are the outer values reached when the endpoint measurements vary within the stated intervals. They do not describe the probability of any actual result.