Torque Converter Stall Speed Calculator
Enter sampled input-shaft torque and two converter capacity factors for zero turbine speed. Find torque balance over the measured curve rather than assuming constant torque. Compare two load curves, inspect a chosen RPM and review any crossing, exact knot or tangent inside the supplied data.
Compare converter stall balance across a torque curve
Use entered input-shaft measurements and zero-speed-ratio capacity factors.
Each converter has one modeled stall balance.
Available torque and converter load
- Available torque
- Converter A load
- Converter B load
- At 2,200 RPM
- Available 345 lb·ft
- Converter A load 484 lb·ft
- Converter B load 274.4802 lb·ft
Modeled RPM balances
Converter A
K ≈ 100 RPM/√lb·ft
- 1,768.063 RPM · Rising crossing
Converter B
K ≈ 132.7906 RPM/√lb·ft
- 2,514.51 RPM · Rising crossing
Exact balance enclosures and CSV
- Converter A · [237305421825/134217728, 118652710925/67108864] RPM
- Converter B · [168745903825/67108864, 337491807675/134217728] RPM
How to use this calculator
- Enter available input-shaft torque samples as RPM, lb·ft, one per line in increasing speed order.
- Enter a confirmed zero-speed-ratio K or supply a documented reference RPM and input torque for each converter.
- Compare the curve and intersection counts. Use the RPM probe to view available torque and modeled load.
- Inspect all retained root intervals and download the exact balance CSV.
The Formula
The mathematical logic powering this calculation is:
Use the zero-turbine-speed capacity factor K in RPM per square root of lb·ft. Its square gives K² = reference input RPM² / reference input torque. The converter's modeled input load at n RPM is n²/K². Use net torque available at the converter input on the same basis as the load factor.
Linear interpolation joins adjacent entered torque samples. On each span, solve n² − K² × available torque = 0. This residual is a quadratic because the available input torque is linear on the span. Split it at its exact stationary point when that point lies strictly inside the span. Each resulting subspan is monotone. Preserve any exact zeros at knots or a tangent, and isolate each strict sign change with up to 32 exact rational bisections. A rising crossing moves from load below available torque to load above it. A falling crossing moves in the other direction. Shared exact knot roots are listed once.
The chart displays approximate coordinates, and the CSV keeps exact interval ends. A balance is a point of equality under the entered static model. Flash behavior, elapsed transients, fluid-temperature effects and fitment require separate data. Interpolation covers only the measured RPM interval. Enter 2–12 ordered samples from 1 to 20,000 RPM and 0 to 20,000 lb·ft with up to four decimals.Worked Example
If you input:
- Torque samples: 200 lb·ft at 800 RPM to 330 lb·ft at 4,000 RPM, with three intermediate readings
- Converter A: K = 100 RPM/√(lb·ft)
- Converter B: 2,300 RPM at 300 lb·ft reference
Result:
Each converter has one modeled balance in the entered interval. The observed load model crosses the entered torque curve at about 1,768.063 and 2,514.510 RPM.
Frequently Asked Questions
What does K mean in this worksheet?
Use input speed divided by the square root of input torque at zero turbine speed, with RPM and pound-feet as the input units.
Can there be two model balances for the same converter?
Yes. The curve can cross a rising load on either side of a local difference maximum or minimum. The worksheet reports every modeled root inside the entered samples.
How does the worksheet find a tangent?
The residual on one interpolated span is quadratic. An exact zero at its stationary point gives a tangent even when the residual has the same sign on either side.
Why do I see zero balances?
The entered load and torque can stay on opposite sides through the available RPM interval. Add relevant measured torque points when they exist.
What is a root enclosure?
It is the exact interval retained around a modeled balance. The two ends are identical when the calculation finds an exact zero.
Similar Calculators
Torque & Horsepower Curve Calculator
Calculate mechanical horsepower and kilowatts from torque and RPM. Plot a dyno run, compare two runs, locate their sampled peaks and estimate where the curves meet.
Engine CFM Calculator & Airflow Demand Curve
Estimate engine airflow from displacement, RPM and volumetric efficiency. Compare two curves and find the exact peak within entered RPM bounds.
Engine Displacement Calculator
Calculate engine size in cc, liters or cubic inches. Compare two bore and stroke combinations and find the dimensions needed for a displacement target.
Motorcycle Gearing, RPM & Shift Planner