Sump Pump Cycle & Storage Calculator

Use the measured effective basin area and switch band, or enter the usable volume directly. Compare two pumps at documented discharge rates under the same inflow. Count starts during an observation window and see whether each enters a repeating cycle.

Sump cycling · Two documented pumps

Compare pump cycles in one sump

Edit basin, flows and start limits

Use a documented usable band and flows at the same operating conditions. The observation begins with the pump off at the lower switch.

Only pump A meets its entered start-rate limit while cycling.

Active basin storage

Usable storage between switches
10 L
Observation from the lower switch
150 s

Pump A · 20 L/min

30 starts/h

Meets the entered start-rate limit.

Starts in observation window
1
Entered maximum
30 starts/h
Pump-off fill time
60 s
Pump-on drawdown time
60 s
Repeating cycle time
120 s

Pump B · 30 L/min

40 starts/h

Exceeds the entered start-rate limit.

Starts in observation window
2
Entered maximum
30 starts/h
Pump-off fill time
60 s
Pump-on drawdown time
30 s
Repeating cycle time
90 s

Inspect the cycle trace and storage check

Active volume over time

Liters above the lower switch

0 s150 s

Volume axis 0 L to 10 L

Solid fill, dashed pump-on phase, dotted upper switch. Rings mark starts.

Pump B · storage at entered limit

Net pump-down flow
20 L/min
First start from lower switch
60 s
Minimum usable storage
13.33333333 L
Additional usable storage
3.33333333 L
Minimum band at this area
26.66666667 mm

Exceeds the entered start-rate limit.

Review the exact pump-cycle ledger

Exact fractions preserve the rate and limit comparison before display rounding.

Cycle timing, start counts and minimum usable storage
PumpNet drawdown (L/min)Fill (s)Pump-down (s)Cycle (s)Steady starts/hObserved startsMinimum storage (L)Minimum band (mm)
A1060601203011020
B2060309040240/380/3

How to use this calculator

  1. Choose area and band or measured usable liters. Use only the volume between your documented switch levels.
  2. Enter a steady inflow and both discharge values for the same chosen hydraulic conditions.
  3. Enter each documented starts-per-hour limit and your observation length. Compare cycle timings and starts before the endpoint.
  4. Inspect the level trace or storage comparison, then export the exact ledger.

The Formula

The mathematical logic powering this calculation is:

Usable volume V is the liquid volume between the pump-stop and pump-start levels. Enter it directly or multiply the effective area in square meters by the measured vertical switch band in millimeters. One square meter times one millimeter equals one liter. Use the band's effective horizontal area after accounting for displaced volume. For a basin with varying section, use a measured usable volume or an average area for that band.

At constant inflow I and discharge P in liters per minute, when 0 < I < P, pump-off fill time is 60V/I seconds and pump-on drawdown time is 60V/(P − I) seconds. One start occurs in each repeating cycle. Divide 3,600 by the cycle seconds to find steady starts per hour. It meets the entered limit S when the rate is at most S. At this same inflow and discharge, minimum usable storage for that one limit is 60I(P − I)/(PS) liters. Divide by the area in area mode to find the implied switch band in millimeters.

The observation starts at the lower switch with the pump off. If the observation ends before the first fill, the start count is zero. Otherwise count the first start and each whole cycle after it through the endpoint. A start exactly at the observation endpoint counts. If pump discharge equals positive inflow, the volume stays at the upper switch once it starts. If discharge is lower, the modeled volume continues to rise. Neither case has a repeating cycle or a storage solution for cycling. Zero inflow produces zero starts from the stated initial condition.

Enter positive direct volume from 0.000001–1,000,000 L, area from 0.000001–1,000 m², switch band from 0.000001–1,000 mm, flow from 0–10,000 L/min, an entered positive maximum from 0.000001–3,600 starts/hour, and an observation window from 0.000001–86,400 seconds. Inputs support six decimals. The trace shows through the observation endpoint or the end of two cycles, whichever comes first. It models relative volume above the lower switch and does not infer basin capacity, overflow, variable inflow or discharge, control delays, pump suitability or allowable switch settings.

Worked Example

If you input:

  • Usable storage: Effective 0.5 m² area × 20 mm band = 10 L
  • Flow and limits: 10 L/min inflow, A 20 L/min, B 30 L/min, each limited to 30 starts/hour
  • Observation: 150 seconds from lower switch with pump off

Result:

A has 60 seconds off and 60 seconds on, exactly 30 starts/hour, with one observed start. B has 60 seconds off and 30 seconds on, 40 starts/hour, with two observed starts. B needs 13⅓ L at the entered rate limit and its second start occurs exactly at 150 seconds.

Frequently Asked Questions

Why subtract inflow from discharge?

Water continues entering during operation. The basin only falls at the difference between the two rates.

Why is the observation count different from starts per hour?

The observation counts individual events from the stated lower-switch start. The steady rate describes a repeated cycle and can be fractional.

What if inflow matches the pump?

The initial fill can reach the upper switch. Once running, the pump balances inflow and has no modeled return to the lower switch.

Can I use a measured volume for a tapered basin?

Yes. Enter the measured volume between the switch levels directly.

Does the minimum band establish equipment limits?

It is the geometric band that meets the entered starts-per-hour comparison at the entered rates. Use the supplier’s limits and project conditions to evaluate an actual installation.

Why can the volume go over the upper switch in the plot?

The upper switch marks when the pump starts. When inflow is higher than discharge, modeled volume continues to rise after that point.