Spindle Runout & Working-Plane Calculator
Audit two sets of already recorded spindle test-bar readings. Reconstruct the first-harmonic radial offset vector at each station. Check whether opposing pairs agree within the entered limits, then estimate the harmonic total indicated runout at your working plane between the two stations.
Audit spindle runout at the working plane
Reconcile indexed dial readings and compare the modeled runout against your entered cap.
Edit axial positions, readings and caps
Modeled working-plane TIR meets the entered cap.
10 µm TIR cap · 0.5 µm closure cap
Near station · 20 mm
0.5 µm
Opposing-pair closure · Within cap
4.472136 µm harmonic TIR at this station
Far station · 100 mm
0 µm
Opposing-pair closure · Within cap
15.620499 µm harmonic TIR at this station
Working plane · 60 mm
10 µm
Modeled working-plane TIR
Offset (+3, +4) µm
Inspect the offset vectors
Radial offset plane (µm)
Circle radius is half the TIR cap
- Near
- Working
- Far
Axial position
Working plane · 60 mm
- Center offset
- (+3, +4) µm
- Harmonic peak-to-peak
- 10 µm
- Fraction along the measured interval
- 0.5
Review the exact runout ledger
| Plane | Axial position (mm) | Offset x (µm) | Offset y (µm) | Pair means (µm) | Closure (µm) | Squared TIR (µm²) |
|---|---|---|---|---|---|---|
| Near station | 20 | 1 | 2 | 29/4 / 27/4 | 1/2 | 20 |
| Working plane | 60 | 3 | 4 | — | — | 100 |
| Far station | 100 | 5 | 6 | 20 / 20 | 0 | 244 |
How to use this calculator
- Enter the two recorded axial stations and a working position between them, relative to the same axial datum.
- Enter each station’s four signed radial readings at matching quarter-turn indices from the same physical angular origin.
- Enter your closure cap in micrometers and the modeled working-plane TIR cap. Both checks include equality.
- Inspect the offset vectors and select each recorded or modeled plane. Read squared TIR and the two pair means in the exact ledger.
- Download the signed readings and modeled values for your record.
The Formula
The mathematical logic powering this calculation is:
For four indexed radial indicator readings r₀, r₉₀, r₁₈₀ and r₂₇₀, define offset components x = (r₀ − r₁₈₀)/2 and y = (r₉₀ − r₂₇₀)/2. The two opposing-pair means are (r₀ + r₁₈₀)/2 and (r₉₀ + r₂₇₀)/2. Their absolute difference is the closure check at that station. A higher value can indicate disagreement with one common baseline. It makes no diagnosis of cause. When both stations meet the entered closure cap, linearly interpolate the x and y offsets at the selected axial plane. Use the same physical angular datum and sign direction for both sets. The axial work coordinate must lie between the entered station coordinates.
The harmonic model is r(θ) = baseline + x cos θ + y sin θ. Modeled total indicated runout (TIR) is its peak-to-peak span, 2√(x² + y²). Squared TIR is 4(x² + y²); compare this exactly with the squared working cap. A result equal to the cap meets it. Compare station closure limits in exact arithmetic too. TIR labels use a square root for display. The plotted radius is half the working-plane TIR cap. Only the working plane receives the entered TIR classification.
Use axial positions in millimeters and signed readings and limits in micrometers. The supported range is ±100,000 for positions and readings, or 0–100,000 for each limit, with up to three decimals. Four samples can miss higher harmonics, form error and other sources of runout. The work estimate applies to the recorded state and the linear center-vector model. Machine operation, dynamic behavior and acceptance require separate evidence.Worked Example
If you input:
- Axial positions: Near 20 mm, working 60 mm, far 100 mm
- Near dial readings: 8.25, 8.75, 6.25, 4.75 µm at 0°, 90°, 180°, 270°
- Far dial readings: 25, 26, 15, 14 µm in the same order
- Entered caps: 0.5 µm pair closure and 10 µm modeled working-plane TIR
Result:
The near station reaches the 0.5 µm closure limit exactly. The working-plane offset is (3, 4) µm, so modeled TIR is 10 µm and meets its cap exactly. At 9.999 µm, those same records exceed the entered TIR cap.
Frequently Asked Questions
Why can the modeled runout differ from the range of my four readings?
The indexed readings reconstruct a sinusoidal model. Its maximum can fall between the listed angles. A continuously measured peak-to-peak trace and the modeled sinusoid can also differ when other harmonics or measurement errors are present.
What does the opposing-pair closure tell me?
A single offset sinusoid predicts equal means for the 0°/180° and 90°/270° pairs. Their observed difference measures that one consistency condition. Small closure cannot establish that other angles follow the same sinusoid.
Why interpolate vectors instead of runout magnitudes?
The radial offset direction can change over the measured length. Interpolating the two signed components captures cancellation when offsets point in different directions.
What happens if the station closure fails?
The recorded stations, their offsets and their closure values remain visible. The worksheet withholds the work-plane interpolation and its cap result.
Similar Calculators
Drilling Speeds and Feeds Calculator
Calculate drill RPM and feed, account for point depth, and compare continuous versus full-retract peck drilling time. Includes motion charts, batch timing and CSV.
Milling Speeds and Feeds Calculator
Calculate milling RPM, cutting speed and table feed from your cutting data. Inspect radial chip thinning and compare explicit machine ceilings.
Gauge Accuracy & Linearity Calculator
Audit gauge accuracy with five reference values and three repeat readings per value. Compare signed bias, repeatability, linearity and lack of fit.