Sealed Woofer Enclosure Calculator & Response Comparison
Enter the measured or published small-signal parameters for one driver and two possible cabinet volumes. Subtract the driver and other internal displacement before comparing Qtc, system resonance and the half-power frequency. The response graph lets you compare the two designs at the same frequency.
Compare two sealed woofer enclosures
Enter driver parameters and cabinet space, then compare net air volume, Qtc and relative response.
Enclosure A reaches half power at a lower frequency.
Edit driver and cabinet inputs
Air volume after displacement
Enclosure A
28 L gross · 24 L net
2 L driver · 2 L other
Enclosure B
52 L gross · 48 L net
2 L driver · 2 L other
Target Qtc 0.8 requires 16 L net. Gross space is 20 L for A or 20 L for B at the entered displacements.
Modeled response across frequency
- Enclosure A at probe
- -9.12 dB
- Enclosure B at probe
- -7.83 dB
Modeled response peak
- Enclosure A
- No peak above the reference level.
- Enclosure B
- No peak above the reference level.
Open selectable CSV
How to use this calculator
- Enter the driver's Fs, Qts and Vas from one consistent measurement or specification set.
- Enter each cabinet's gross internal volume and the internal displacement occupied by the driver and other components.
- Compare the two net air volumes, resonance frequencies, half-power frequencies and response curves.
- Choose a probe frequency or enter a target Qtc to solve the theoretical required volume.
- Download the parameters, derived values and plotted response samples.
The Formula
The mathematical logic powering this calculation is:
Net air volume Vb equals gross internal volume minus the driver and other physical displacement. Enclosure walls are outside the gross internal measurement. Use liters for all volumes, Hz for frequencies, and dimensionless Q values. Use one driver per sealed cabinet in the same small-signal model.
In this ideal closed-box alignment, g = √(1 + Vas/Vb). System resonance Fc = Fs × g and total system Qtc = Qts × g. For frequency f with y = f/Fc, the magnitude relative to the model's high-frequency reference is y² / √[(1 − y²)² + (y/Qtc)²]. Convert that magnitude to decibels with 20 × log₁₀(magnitude).
At half power, the squared magnitude equals 1/2, about −3.01 dB. Put t = (f/Fc)². Solve t² − (1/Qtc² − 2)t − 1 = 0 for the positive t, then multiply √t by Fc. A modeled peak above the reference exists if Qtc > 1/√2. Its frequency is Fc × √[2/(2 − 1/Qtc²)]. A higher Q can lower the half-power frequency while changing the shape near resonance, so compare the whole curve and the probe value.
To solve the volume for a target Qtc above Qts, use Vb = Vas × Qts²/(Qtc² − Qts²) and add each candidate's physical displacement for its gross space. A finite positive sealed box cannot reach Qtc at or below the free-air Qts in this model.
The ideal second-order small-signal model assumes a sealed cabinet and simple air compliance. It shows relative response and does not predict maximum output, excursion, room response, power handling, leakage, enclosure resonances, damping fill or construction suitability. The volume subtraction uses exact decimal resolution. Resonance and response use floating-point arithmetic and the display is rounded.Worked Example
If you input:
- Driver: Fs 30 Hz, Qts 0.4, Vas 48 L
- Gross cabinet spaces: A 28 L, B 52 L
- Displacement: 2 L driver and 2 L other in each cabinet
- Probe and target: 32 Hz and Qtc 0.8
Result:
Enclosure A has 24 L net and reaches half power at 53.055091 Hz. B has 48 L net and reaches half power at 55.477252 Hz. B is closer to the reference at the 32 Hz probe. Qtc 0.8 requires 16 L net.
Frequently Asked Questions
What is the net volume of a sealed enclosure?
Start with the space within the enclosure walls, then subtract the driver and other solid parts occupying that space. The remaining air volume is used in the model.
What does Qtc measure?
It is the total quality factor of the driver and sealed cabinet modeled together. It affects the response curve near system resonance.
Can a smaller enclosure have a lower half-power frequency?
Yes. Reducing net volume increases both system resonance and total Q. Their effects on the half-power frequency can move in different directions, so the response shape and the chosen probe frequency matter.
Why might a target Qtc have no volume?
The closed-box model makes system Qtc greater than free-air Qts for any finite positive net volume. A lower or equal target has no finite solution.
Does the curve show absolute sound pressure?
It shows the predicted magnitude relative to the model's high-frequency reference for an ideal small-signal alignment. Room position and absolute output need other measurements.
Similar Calculators
Speaker Impedance & Amplifier Load Planner
Calculate speaker ohms for series and parallel layouts. Compare nominal loads with complex impedance at measured frequencies, phase and ideal RMS power.
Passive Filter Bode Plot & Load Planner
Plot gain and phase for two loaded RC or series RLC filters. Compare cutoff shifts, half-power frequencies and source-referenced gain at your test frequency.
Wavelength & Phase Path Calculator
Calculate frequency and wavelength in up to four media. Compare path delay, wrapped phase and the shared frequency range for entered lengths.
