Screen Printing Exposure Calculator & Step Wedge Planner
Record the highest fully retained step after each trial and choose a target from your emulsion or verified shop procedure. The worksheet estimates the threshold for that step under a 0.15-density wedge model. It checks whether two trials agree and identifies the timer settings that match the target across the inferred threshold range.
Match exposure trials to your timer
Compare your measured readings before choosing a follow-up exposure on the same setup.
14 timer settings match from 28.5 s to 35 s.
Continuous modeled window 28.183829 s through 35.397289 s
Thresholds and matching timer settings
Open dots show a lower bound that the threshold must exceed. Arrows mark an endpoint the trial could not measure.
Open exposure trial ledger
| Trial | Time | Highest retained step | Target threshold |
|---|---|---|---|
| Trial A | 10 s | 4 | Above 19.952623 s through 28.183829 s |
| Trial B | 50 s | 8 | Above 25.059362 s through 35.397289 s |
Open selectable CSV
How to use this calculator
- Check that your strip uses 21 steps with a nominal 0.15 density increment. Enter the target step from the procedure you are using.
- Enter Trial A’s measured exposure time and highest fully retained step after washout. Enter 0 for no fully retained steps.
- Add Trial B if it used the same setup and assessment. Compare their threshold intervals. Recheck inconsistent observations.
- Enter your timer’s range and increment. Review the available settings and use another trial to verify the result.
- Open the threshold ledger or download the worksheet CSV to keep the tested settings and observations.
The Formula
The mathematical logic powering this calculation is:
For a 21-step wedge with 0.15 optical density between neighboring steps, the model uses q = 10^0.15, approximately 1.41254. It assumes a fixed effective exposure rate, equal density increments and repeatable coating, exposure and washout. Thresholds for consecutive steps differ by this factor. The time range to hold the target step k starts when the target threshold is met and ends just before the following step threshold.
If a trial of t seconds fully retains step s from 1 through 20, the target threshold is greater than t × q^(k − s − 1) and at most t × q^(k − s). A zero reading supplies only the lower endpoint because the first step was missed. An all-21 reading supplies only the upper endpoint because the strip has no next step. If you enable Trial B, use the same setup. The shared model intersects the trial ranges from both tests. A gap or touching open lower endpoint means the readings disagree under the model.
For a bounded shared target threshold (L, U], every compatible threshold would retain exactly k at any modeled setting from U through q × L, inclusive. If those setting limits cross, the readings give no single timer value that satisfies the full inferred range. One unsaturated trial generally leaves one theoretical setting before timer rounding. A second overlapping trial may widen the range by narrowing threshold uncertainty. When one endpoint is unobserved, the worksheet cannot establish a bounded setting range. A recommended next test is the lower middle valid timer setting, with valid counts based on positive integer multiples of the entered timer increment, clipped to the entered minimum and maximum. Bound comparisons account for near-identical floating point endpoints.
Supported tested, minimum, maximum and increment times are 0.001–14,400 seconds, up to three decimals. Observed steps range from 0 through 21. The target is step 1–20 so the model always has a next-step boundary. The results are test settings for the nominal wedge and comparable entered trials. Keep your own emulsion, equipment and processing instructions in view and verify each candidate with a new screen. Nonuniform light, warmup or long-exposure response, a calibrated wedge with unequal step intervals, a different strip design and material or workflow changes can invalidate the shared model.Worked Example
If you input:
- Target fully retained step: 7
- Trial A: 10 s; step 4 held
- Trial B: 50 s; step 8 held
- Timer: 1–180 s in 0.5 s increments
Result:
The tests agree on a target threshold above 25.059362 s and through 28.183829 s. The timer has 14 valid settings from 28.5 s through 35 s. The lower middle setting is 31.5 s for a follow-up test.
Frequently Asked Questions
Does this calculate a standard exposure time from mesh count?
Enter measured times and retained steps. The ratio applies to the particular wedge model and stable setup. Mesh, emulsion, coating and light can change the underlying threshold.
What should I enter for a partly retained step?
Use the highest fully retained step. Use the same assessment rule for both trials. Record zero if none of the steps fully retained.
Why can the trials disagree?
The observed times and steps may imply mutually exclusive threshold ranges. A change in coating, light or washout, or a reading or entry error, can explain a mismatch. Recheck the trial readings under the same procedure.
What if the worksheet shows a setting between timer ticks?
The continuous modeled time window may fit the limits you entered but fall between the timer’s actual increments. Keep the window and use an additional comparable test to narrow your threshold range.
Can I use a different wedge or a percentage filter?
This worksheet uses one nominal 0.15-density increment. Other step spacings and percentage filters use different transmission relationships.
Why does a 21-step wedge only allow targets through 20?
The calculation compares the threshold for the chosen step with the threshold for its next step. Step 21 can be entered as an observed limit.
Similar Calculators
Photo Print Size & Crop Calculator
Compare print sizes, native pixels per inch, and fit or fill cropping without resampling. Preview an optional local photo and calculate the minimum dimensions for a printer's target PPI.
First-Pass Yield & Rework Audit
Compare two production lots by stage. Separate first-pass yield, units recovered after rework, scrap, and tracked clean-through yield.
Production Cycle Time & Batch Capacity Planner
Compare production cycle time, whole-lot shift output and bottleneck timing for two process sequences. See when planned batches finish and how much demand fits.
T-Shirt Screen Printing Cost & Reorder Quote Planner
Compare custom T-shirt quotes by print placement, ink colors, quantity break, underbase and confirmed reorder screens.