Measured Room Decay & RT60 Calculator
Use one recorded frequency band and compare two monotone decay traces at six shared equally spaced times. Estimate 60 dB decay time from a linear fit, see which samples are used, and check whether both the time and entered floor clearance qualify.
Compare measured room decays
Fit the sampled drop band, then compare the estimated decay time and its clearance above the noise floor.
Edit sample drops, floors and fit limits
Use comparable traces at one frequency band. Each starts at 0 dB drop. Enter positive drop values for the evenly spaced samples that follow.
Only trace A meets the entered checks.
Trace A
- Estimated RT60
- 1,200 ms
- Clearance above noise floor
- 10 dB
Meets floor clearance and time target
Trace B
- Estimated RT60
- 1,000 ms
- Clearance above noise floor
- 9.999 dB
Below the required floor clearance
Inspect a decay trace
Drop below the reference level
0 to 40 dB
- Trace A
- Trace B
- Fit band
- Selected noise floor
- Selected fit
Trace A
Fit band 5 dB–25 dB
Minimum floor clearance 10 dB
Time target 1,200 ms
- First fit crossing
- 100 ms
- Last fit crossing
- 500 ms
- Points in fit
- 5
- Slope
- 50 dB/s
Review the exact decay ledger
| Elapsed | Trace A drop | Trace B drop | Trace A fit point | Trace B fit point |
|---|---|---|---|---|
| 0 ms | 0 dB | 0 dB | — | — |
| 100 ms | 5 dB | 6 dB | start | interior |
| 200 ms | 10 dB | 12 dB | interior | interior |
| 300 ms | 15 dB | 18 dB | interior | interior |
| 400 ms | 20 dB | 24 dB | interior | interior |
| 500 ms | 25 dB | 30 dB | end | — |
How to use this calculator
- Enter the common sample spacing, fit drop band and your time and floor-clearance limits.
- Copy five normalized decay drops after the shared reference time for each trace.
- Enter the noise-floor drop relative to each trace’s own reference level.
- Inspect the samples and fitted span. Compare both criteria and export the exact point ledger.
The Formula
The mathematical logic powering this calculation is:
Enter two recorded monotone decay envelopes at the same six equally spaced times, in one comparable frequency band. The first point is fixed at zero drop. Enter positive drop in dB below each trace’s reference for the next five points. For example, a relative reading of −12 dB is a drop of 12 dB. Enter the noise floor as a drop below that same reference. To compare repeat measurements, use shared timing, reference and frequency-band conventions.
Find the first time each trace reaches the start and end drop. Use linear interpolation when a threshold lies between samples. If a trace stays exactly on a boundary for multiple samples, use its first crossing. The fit uses the two exact crossings and every original sample with time strictly between them. Fit a line to drop versus time by unweighted ordinary least squares. A slope of m dB/s gives an estimated 60 dB decay time of 60/m seconds. The default fit uses a 5–25 dB drop range, as illustrated in instrumentation documentation.
Floor clearance is entered noise-floor drop minus the end drop. The entered floor clearance and maximum decay-time criteria are independent and inclusive. The time fit may be shown for inspection even if floor clearance is too small. If a trace never reaches the end drop, the worksheet has no fit for that trace. User-entered thresholds and the worksheet’s sample selection define this comparison. Instrument measurement protocols, source selection and compliance evaluation require separate evidence.
Sample spacing and time target accept 1–60,000 whole ms. Drops and floor clearances accept 0–160 dB with up to three decimals. End drop must exceed start drop and recorded drop must never decrease. The two interpolated times, slope, intercept and decay estimate are exact rational values from the entered sample grid. The curve connects the measured points and the approximate drawing uses the same outputs.Worked Example
If you input:
- Timing: 100 ms spacing and 1,200 ms target.
- Fit and floor clearance: 5–25 dB drop band and at least 10 dB clearance.
- Trace A: 5, 10, 15, 20 and 25 dB drops. Floor at 35 dB below reference.
- Trace B: 6, 12, 18, 24 and 30 dB drops. Floor at 34.999 dB below reference.
Result:
A estimates 1,200 ms at exactly 10 dB floor clearance. B estimates 1,000 ms with 9.999 dB clearance. Only A meets both entered checks.
Frequently Asked Questions
Is a displayed RT60 estimate directly measured for all 60 dB?
The estimate extrapolates the slope of your selected measured range out to a 60 dB decay.
Why does a faster fitted trace sometimes miss the check?
The fit can be fast while its lower end is close to the measured noise floor. This worksheet checks both entered thresholds.
What if my last sample stays above the end of the fit band?
The worksheet has no recorded crossing for the end of the band. It shows the available samples and leaves the fit incomplete.
Which points does the fit use?
It uses both crossings and original samples strictly between them. A threshold exactly at a sample counts once.
Can I compare a plot at one frequency band with a different one?
Use the same band and measurement convention for both traces so they describe comparable decays.
Similar Calculators
Room Acoustics & Reverberation Time Calculator
Compare room reverberation and acoustic treatment area across six frequency bands. See what changes when the ceiling or another surface is treated.
Speaker Placement Calculator
Compare two listening seats in a rectangular room. Calculate stereo angle, direct timing mismatch, and first wall reflection paths.
Sound Transmission Loss & Partition Gap Calculator
Compare wall and door sound transmission with measured gap areas. See the power through each path and the allowable modeled gap by band.
Weighted Linear Regression Calculator
Fit weighted and ordinary regression lines from observations with known response SDs. Compare uncertainty, leverage, and held-out residuals.
