Room Acoustics & Reverberation Time Calculator

Estimate RT60 for a rectangular room before and after two proposed treatments. Use documented absorption by frequency and your own decay limits. Compare modeled decay curves and calculate the exact treatment-area window for each chosen surface.

Six-band reverberation and surface treatment

Compare room decay before and after treatment

Both treatments meet all six entered decay targets.
Room volume
120 m³
0 of 6 bands meet targets before treatment
Treatment A
6 of 6 bands
Meet their entered decay target
Treatment B
6 of 6 bands
Meet their entered decay target

Frequency band

Modeled decay at 500 Hz

The vertical dashed line marks the entered 0.6 s target. Each slope runs to a 60 dB drop.

  • Original room1.222785 s · Above target
  • Treatment A0.6 s · Meets target
  • Treatment B0.592638 s · Meets target
500 Hz absorption and target
Qualifying treatment areas

Colored lines show all areas that meet every band target. Dots mark the entered areas on the same scale.

  • Treatment A · Long walls

    32.8–48 m²

    32.8 m² entered

  • Treatment B · Ceiling

    29.818182–40 m²

    30 m² entered

Rectangular room
Treatment A patch
Treatment B patch
Review decay by band and exact CSV
Modeled decay times and target by band
FrequencyMaximum RT60Original roomTreatment ATreatment B
125 Hz0.6 s0.873418 s · Above0.519243 s · Meets0.546999 s · Meets
250 Hz0.6 s1.018987 s · Above0.556708 s · Meets0.563923 s · Meets
500 Hz0.6 s1.222785 s · Above0.6 s · Meets0.592638 s · Meets
1,000 Hz0.6 s1.222785 s · Above0.560065 s · Meets0.598142 s · Meets
2,000 Hz0.6 s0.940604 s · Above0.472649 s · Meets0.517408 s · Meets
4,000 Hz0.6 s0.873418 s · Above0.448135 s · Meets0.488866 s · Meets

How to use this calculator

  1. Measure the inside room length, width and height in metres. Assign measured or published absorption coefficients to each original surface group.
  2. Choose which surface group each treatment would replace and enter its net patch area in square metres.
  3. Select each octave band to enter its original surface coefficients, the two proposed material coefficients and your maximum decay time.
  4. Review the decay plot, band-by-band results and the qualifying area interval, then download the precise absorption and RT60 ledger.

The Formula

The mathematical logic powering this calculation is:

For each frequency band, sum each surface group's area S times its entered absorption coefficient α to get equivalent absorption A. Use separate areas for floor, ceiling, the two long walls and the two short walls. Volume V is room length × width × height. The Sabine estimate is RT60 = 0.161V/A, using metres, square metres and seconds. An entered total absorption of zero gives no finite modeled decay time.
A treatment replaces the original surface at the same area. For patch area x, the changed absorption is baseline A + x(α new − α old). The exact target comparison is A after treatment ≥ 0.161V / target seconds. Equality meets the entered limit. Each band constrains x from below if its absorption rises, or from above if it falls. Intersect all six band conditions with zero to the area of the selected surface group. An empty intersection means no area of that one treatment matches all six targets.
Enter six bands at 125, 250, 500, 1,000, 2,000 and 4,000 Hz, with coefficient inputs between 0 and 1 and a maximum decay time from 0.01 to 60 s for each band. Each room dimension supports 0.1–200 m. The illustrated model assumes a diffuse sound field and simplified surface groups. It omits air absorption, exact material placement, nonuniform room modes and any special occupancy treatment. Estimates should be compared with actual measurement when evaluating a finished space.

Worked Example

If you input:

  • Room: 8 m × 5 m × 3 m, 120 m³
  • 500 Hz example: 0.10 across existing surfaces. A replaces 32.8 m² of the long walls with α 0.60. B replaces 30 m² of ceiling with α 0.66.
  • Maximum RT60: 0.60 s in each of the six modeled bands

Result:

A meets the 500 Hz target at 0.60 s exactly. B gives about 0.593 s at 500 Hz, and both meet all six entered targets.

Frequently Asked Questions

What does room reverberation time measure?

RT60 is the time for the sound level to decay by 60 decibels after its source stops. The chart draws the decay implied by the Sabine estimate.

Why provide six absorption coefficients?

The same material can absorb very different amounts of sound at low and high frequencies. A single averaged coefficient can hide the band that limits a plan.

How does treatment affect a ceiling or wall?

The modeled patch replaces the original surface coefficient over the same area. Only the difference in absorption is added to the room baseline.

Why can more treatment make one band fail?

A proposed material may absorb less than the original surface in that band. The area interval shows when increasing coverage would cross the band limit.

Can I use this to predict sound transmission through a wall?

This worksheet models decay inside a room. Transmission through a wall also depends on the wall assembly, joints and adjacent paths.

Similar Calculators