High-Bay Lighting & Workplane Illuminance Calculator
Use one set of documented light intensities to compare two positions for a pair of matching, downward-facing fixtures. The worksheet estimates contributions at the centers of nine equal workplane cells, compares left and right contributions and summarizes the minimum, mean and ratio across the measured area.
Compare two high-bay lighting layouts
Use the fixture candela curve to estimate direct light at nine matched workplane samples.
Each cell shows its modeled center value. Select a sample to inspect its contributions at the 82 lx target.
Fixture projections across the 18 m width
Sample 5 · 0 m across, 0 m along
Left fixture 127.268 lx · Right fixture 127.268 lx · Background 5 lx · Total 259.536 lx
Review sample contributions and CSV
| Layout and sample | Left fixture | Right fixture | Total | Minimum |
|---|---|---|---|---|
| Layout A · 1 | 97.385 lx | 5.99 lx | 108.375 lx | Meets |
| Layout A · 2 | 37.193 lx | 37.193 lx | 79.385 lx | Below |
| Layout A · 3 | 5.99 lx | 97.385 lx | 108.375 lx | Meets |
| Layout A · 4 | 258.749 lx | 7.369 lx | 271.118 lx | Meets |
| Layout A · 5 | 66.822 lx | 66.822 lx | 138.643 lx | Meets |
| Layout A · 6 | 7.369 lx | 258.749 lx | 271.118 lx | Meets |
| Layout A · 7 | 97.385 lx | 5.99 lx | 108.375 lx | Meets |
| Layout A · 8 | 37.193 lx | 37.193 lx | 79.385 lx | Below |
| Layout A · 9 | 5.99 lx | 97.385 lx | 108.375 lx | Meets |
| Layout B · 1 | 66.375 lx | 12.877 lx | 84.251 lx | Meets |
| Layout B · 2 | 66.375 lx | 66.375 lx | 137.749 lx | Meets |
| Layout B · 3 | 12.877 lx | 66.375 lx | 84.251 lx | Meets |
| Layout B · 4 | 127.268 lx | 16.771 lx | 149.039 lx | Meets |
| Layout B · 5 | 127.268 lx | 127.268 lx | 259.536 lx | Meets |
| Layout B · 6 | 16.771 lx | 127.268 lx | 149.039 lx | Meets |
| Layout B · 7 | 66.375 lx | 12.877 lx | 84.251 lx | Meets |
| Layout B · 8 | 66.375 lx | 66.375 lx | 137.749 lx | Meets |
| Layout B · 9 | 12.877 lx | 66.375 lx | 84.251 lx | Meets |
How to use this calculator
- Measure the horizontal sample area. Enter the target minimum and minimum-to-mean ratio you want to check.
- Enter candela readings in four directions from the same fixture data, plus any measured constant background you want to add.
- Enter fixture height above the workplane, separation and retained-light fraction for each plan.
- Compare the sample grids and inspect individual contributions or export the numeric worksheet.
The Formula
The mathematical logic powering this calculation is:
Use a rectangular horizontal workplane centered at zero. The three sample columns lie at x = negative width/3, zero and positive width/3. The three rows use the corresponding longitudinal dimension. The two fixture projections sit on the centerline at plus and minus half their separation. Heights are measured vertically above the workplane.
For each fixture and point, find horizontal distance r and slant distance d = sqrt(h² + r²). The ray angle from vertical is atan2(r,h), converted to degrees. Interpolate between the two nearest entered intensity readings at 0, 30, 60 and 90 degrees. The light model assumes the distribution is the same at every azimuth. Horizontal illuminance from that fixture is candela at the ray angle × h/d³. Multiply the direct contributions by the entered retained-light fraction, then add both and the entered constant background.
The nine equal-area sample centers have equal weight. Sample uniformity is 100 × minimum divided by mean. With a zero mean, the ratio is unavailable. Enter zero as the threshold to compare only the minimum. Both entered criteria apply to the nine modeled points. Comparisons count equality within 1e−9 × max(1, threshold) for floating arithmetic. Check the underlying measurements near a narrow boundary.
Width, length and height are 0.1–100 m. Fixture separation is 0.001–100 m and cannot exceed the entered width. Candela readings are 0–1,000,000. Background and minimum thresholds are 0–10,000 lx. Retained light and the ratio target are 0–100%. Inputs accept up to four decimals. The worksheet exports computed values to twelve significant digits. Displayed rounding does not change either modeled comparison.
Use published or measured candela readings on the same basis at every angle. The model estimates direct light from two point sources plus an entered background. Reflections, asymmetric beam patterns, obstruction, continuous minima between samples, equipment placement and lighting compliance need separate information.Worked Example
If you input:
- Workplane: 18 m × 12 m
- Photometry: 8,000, 7,000, 3,500 and 200 cd
- Layout A: 5 m high, 10 m apart
- Layout B: 6 m high, 6 m apart
- Targets: 82 lx minimum and 28% minimum-to-mean
Result:
The weakest sample is about 79.385 lx for A and 84.251 lx for B. Only Layout B meets both entered criteria. Moving the minimum to 84.252 lx leaves four of B's samples below the threshold.
Frequently Asked Questions
Why are candela values needed rather than fixture lumens?
Total lumens describe the fixture's overall emitted flux. Point illuminance depends on the intensity along the ray toward each sample.
Can the sample minimum prove the entire floor reaches my target?
No. It is the smallest of the nine modeled values. A denser grid and field measurements can reveal changes between these sample centers.
What does a 100% minimum-to-mean ratio mean?
All nine modeled values are equal when the mean is positive. A high ratio can coexist with low light levels across the grid.
What dimensions enter the distance formula?
Enter vertical luminaire height above the evaluated workplane. The formula adds lateral separation to compute slant distance to the actual sample.
Similar Calculators
Room Lumens & Maintained Illuminance Calculator
Estimate average maintained workplane illuminance from measured light or fixture data. Compare whole fixture counts under entered position and watt limits.
Recessed Lighting Layout Calculator
Compare recessed-light center grids, spacing and wall offsets. Inspect coordinates and entered keep-out conflicts on a scaled room plan.
Window Film Light Transmission & Quote Planner
Compare architectural window film light transmission on matching glazing, whole-roll cut plans and entered installation prices.
Electricity Cost Calculator
Estimate appliance electricity cost from wattage, daily use, electricity rate, and billing fees.