Foot-Candle Workplane Survey & Lumens Calculator

Compare before and after meter readings on the same rectangular work surface. Divide the plane into four measured regions with custom offsets. See how larger regions influence the estimated average and incident lumens, and how much area is represented by readings that meet the entered floor.

Measured lighting audit

Audit light from measured foot-candles

Edit workplane, thresholds and survey readings
Survey A
Survey B

Only Survey B meets both entered limits.

200 ft² workplane · 20 fc zone floor · 76% required area

Survey A

Misses a limit

23.12 fc

Area-weighted average

Area meeting floor
76%
Estimated incident light
4,624 lm

Survey B

Meets both limits

26.12 fc

Area-weighted average

Area meeting floor
76%
Estimated incident light
5,224 lm

Inspect the measured workplane

North at top · 20 × 10 ft

Survey A

Survey B

  • At or above floor
  • Below floor

Southeast · 48 ft² · 24% of plane

Survey A · 19 fc · Below zone floor

912 estimated incident lm

Survey B · 20 fc · Meets zone floor

960 estimated incident lm

Survey B − A · 1 fc

Review exact zone and survey ledger
Exact workplane readings, area and estimated lumens
SurveyZoneArea (ft²)Reading (fc)Floor margin (fc)Incident lumensZone floor
ASouthwest32233736Meets
ASoutheast4819-1912Below
ANorthwest482331104Meets
ANortheast722661872Meets
BSouthwest3235151120Meets
BSoutheast48200960Meets
BNorthwest4819-1912Below
BNortheast7231112232Meets

How to use this calculator

  1. Measure the rectangular workplane and enter both interior dividing lines.
  2. Copy representative meter readings in foot-candles for each zone under both survey conditions.
  3. Enter a zone-level floor, a weighted-average minimum and a required qualifying area percentage.
  4. Compare average, estimated incident lumens and mapped coverage. Select a zone to see its area and measured changes.
  5. Open the exact ledger or download all measured and modeled values.

The Formula

The mathematical logic powering this calculation is:

One foot-candle equals one incident lumen per square foot. Use a rectangular horizontal workplane, with distances measured from the west and south edges. A vertical column boundary and a horizontal row boundary produce four rectangles. Width × depth is each zone’s area. For each survey, estimated incident lumens equal the sum of zone area × representative foot-candle reading. Weighted average foot-candles equals this sum divided by total workplane area.
A zone qualifies when its representative reading equals or exceeds the entered floor. Qualifying area is the sum of the qualifying zones’ actual areas. Divide by total area and multiply by 100 for percent qualifying area. A survey qualifies when both the entered weighted-average minimum and qualifying-area percentage are met. Exact rational arithmetic treats all three comparisons as inclusive.
Use the same workplane and zone boundaries for both surveys, with comparable meter orientation and documented conditions. Each reading represents its entire zone in this model. The result estimates incident light at the plane. Light between readings, luminaire output, installed power, compliance and continuous minimum measurements require separate information.
Total dimensions and interior boundary positions accept 0.001–1,000 ft. Boundaries must be strictly interior. Zone readings, zone floor and average targets accept 0–10,000 fc. The area target accepts 0–100%. Inputs allow up to three decimal places.

Worked Example

If you input:

  • Workplane: 20 × 10 ft. Boundaries are 8 ft east from west and 4 ft north from south.
  • Survey A: 23, 19, 23, and 26 fc in SW, SE, NW and NE order.
  • Survey B: 35, 20, 19 and 31 fc in the same order.
  • Targets: 20 fc zone floor, 26.12 fc minimum weighted average, 76% qualifying area.

Result:

Only Survey B meets both limits with an exact 26.12 fc weighted average and 76% qualifying area. It estimates 5,224 incident lumens. Raising the zone floor to 20.001 fc moves the 48 ft² southeast zone below the floor, reducing B’s qualifying area to 52%.

Frequently Asked Questions

Why is the weighted average different from averaging the four meter readings?

Each reading represents the actual area of its zone. A larger zone contributes more to total estimated incident lumens and the weighted average.

Do these lumens describe the light fixtures’ total output?

These lumens estimate the light reaching the selected workplane under the recorded conditions. Emitted luminaire output is a separate quantity.

Why does qualifying area jump when the floor changes slightly?

The model assigns the entire represented zone to one side of the comparison. A small change across its reading moves that zone’s full area.

Does a passing zone mean the reading is that high throughout it?

The reading is the zone’s representative value in this model. More measurements are needed to locate variation within a zone.