Foot-Candle Workplane Survey & Lumens Calculator
Compare before and after meter readings on the same rectangular work surface. Divide the plane into four measured regions with custom offsets. See how larger regions influence the estimated average and incident lumens, and how much area is represented by readings that meet the entered floor.
Audit light from measured foot-candles
Compare two workplane surveys using the actual area represented by each meter reading.
Edit workplane, thresholds and survey readings
Only Survey B meets both entered limits.
200 ft² workplane · 20 fc zone floor · 76% required area
Survey A
Misses a limit23.12 fc
Area-weighted average
- Area meeting floor
- 76%
- Estimated incident light
- 4,624 lm
Survey B
Meets both limits26.12 fc
Area-weighted average
- Area meeting floor
- 76%
- Estimated incident light
- 5,224 lm
Inspect the measured workplane
North at top · 20 × 10 ft
Survey A
Survey B
- At or above floor
- Below floor
Southeast · 48 ft² · 24% of plane
Survey A · 19 fc · Below zone floor
912 estimated incident lm
Survey B · 20 fc · Meets zone floor
960 estimated incident lm
Survey B − A · 1 fc
Review exact zone and survey ledger
| Survey | Zone | Area (ft²) | Reading (fc) | Floor margin (fc) | Incident lumens | Zone floor |
|---|---|---|---|---|---|---|
| A | Southwest | 32 | 23 | 3 | 736 | Meets |
| A | Southeast | 48 | 19 | -1 | 912 | Below |
| A | Northwest | 48 | 23 | 3 | 1104 | Meets |
| A | Northeast | 72 | 26 | 6 | 1872 | Meets |
| B | Southwest | 32 | 35 | 15 | 1120 | Meets |
| B | Southeast | 48 | 20 | 0 | 960 | Meets |
| B | Northwest | 48 | 19 | -1 | 912 | Below |
| B | Northeast | 72 | 31 | 11 | 2232 | Meets |
How to use this calculator
- Measure the rectangular workplane and enter both interior dividing lines.
- Copy representative meter readings in foot-candles for each zone under both survey conditions.
- Enter a zone-level floor, a weighted-average minimum and a required qualifying area percentage.
- Compare average, estimated incident lumens and mapped coverage. Select a zone to see its area and measured changes.
- Open the exact ledger or download all measured and modeled values.
The Formula
The mathematical logic powering this calculation is:
One foot-candle equals one incident lumen per square foot. Use a rectangular horizontal workplane, with distances measured from the west and south edges. A vertical column boundary and a horizontal row boundary produce four rectangles. Width × depth is each zone’s area. For each survey, estimated incident lumens equal the sum of zone area × representative foot-candle reading. Weighted average foot-candles equals this sum divided by total workplane area.
A zone qualifies when its representative reading equals or exceeds the entered floor. Qualifying area is the sum of the qualifying zones’ actual areas. Divide by total area and multiply by 100 for percent qualifying area. A survey qualifies when both the entered weighted-average minimum and qualifying-area percentage are met. Exact rational arithmetic treats all three comparisons as inclusive.
Use the same workplane and zone boundaries for both surveys, with comparable meter orientation and documented conditions. Each reading represents its entire zone in this model. The result estimates incident light at the plane. Light between readings, luminaire output, installed power, compliance and continuous minimum measurements require separate information.
Total dimensions and interior boundary positions accept 0.001–1,000 ft. Boundaries must be strictly interior. Zone readings, zone floor and average targets accept 0–10,000 fc. The area target accepts 0–100%. Inputs allow up to three decimal places.Worked Example
If you input:
- Workplane: 20 × 10 ft. Boundaries are 8 ft east from west and 4 ft north from south.
- Survey A: 23, 19, 23, and 26 fc in SW, SE, NW and NE order.
- Survey B: 35, 20, 19 and 31 fc in the same order.
- Targets: 20 fc zone floor, 26.12 fc minimum weighted average, 76% qualifying area.
Result:
Only Survey B meets both limits with an exact 26.12 fc weighted average and 76% qualifying area. It estimates 5,224 incident lumens. Raising the zone floor to 20.001 fc moves the 48 ft² southeast zone below the floor, reducing B’s qualifying area to 52%.
Frequently Asked Questions
Why is the weighted average different from averaging the four meter readings?
Each reading represents the actual area of its zone. A larger zone contributes more to total estimated incident lumens and the weighted average.
Do these lumens describe the light fixtures’ total output?
These lumens estimate the light reaching the selected workplane under the recorded conditions. Emitted luminaire output is a separate quantity.
Why does qualifying area jump when the floor changes slightly?
The model assigns the entire represented zone to one side of the comparison. A small change across its reading moves that zone’s full area.
Does a passing zone mean the reading is that high throughout it?
The reading is the zone’s representative value in this model. More measurements are needed to locate variation within a zone.
Similar Calculators
Room Lumens & Maintained Illuminance Calculator
Estimate average maintained workplane illuminance from measured light or fixture data. Compare whole fixture counts under entered position and watt limits.
High-Bay Lighting & Workplane Illuminance Calculator
Compare two high-bay fixture layouts using four candela readings. Inspect horizontal illuminance at nine workplane samples and compare minimum-to-mean ratios.
Recessed Lighting Layout Calculator
Compare recessed-light center grids, spacing and wall offsets. Inspect coordinates and entered keep-out conflicts on a scaled room plan.