Dehumidifier Water Removal & Energy Calculator

Use a logged powered duration, collected water and optional meter reading for each trial. Estimate hours and energy to remove a specified quantity of water when logged conditions are representative, then compare two daily schedules.

Logged water collection and power measurements

Compare dehumidifier water removal and daily energy

Use timed trials to check a daily water target against each unit’s available powered hours.

Only Trial A reaches the daily water target.

Target 6 L per day.

Trial A

7 L in the available window

Observed 0.5 L/h · 14 h available per day.

The target fits within available hours.

12 h needed for the target.

3 kWh and $0.72 to reach the target.

Trial B

4.5 L in the available window

Observed 0.75 L/h · 6 h available per day.

Available powered hours fall short.

8 h needed for the target.

Projected shortfall 1.5 L.

Full available window 0.9 kWh.

Water removed by powered hour

Measured-rate water removal and schedule limitsThe daily target is 6 L. Trial A has 14 available hours and projects 7 L. Trial B has 6 available hours and projects 4.5 L.Liters removed0 h12 h24 h
Trial ATrial BDaily targetAvailable hours

8 h selected. Each result stops at its available hours.

  • Trial A 4 L
  • Trial B 4.5 L
Edit the daily water target
Edit the logged trials and available hours

Record water and meter energy over the same elapsed powered window, including cycling. Leave energy blank when it was unmetered.

Trial A
Trial B
Review the trial and target calculations

Trial A

Trial rate 4 L ÷ 8 h = 1/2 L/h.

Observed removal per meter energy 2 L/kWh.

Window water 1/2 L/h × 14 h = 7 L.

Target hours 6 L ÷ 1/2 L/h = 12 h.

Target energy 1/4 kWh/h × 12 h = 3 kWh. The charge is 18/25 USD before cent rounding.

Trial B

Trial rate 15/2 L ÷ 10 h = 3/4 L/h.

Observed removal per meter energy 5 L/kWh.

Window water 3/4 L/h × 6 h = 9/2 L.

Target hours 6 L ÷ 3/4 L/h = 8 h.

Show dehumidifier CSV text

How to use this calculator

  1. Enter the planned daily water target and select its liquid unit.
  2. Record elapsed powered trial hours and collected volume for each option.
  3. Enter energy measured over the same elapsed window and available powered hours per day.
  4. Confirm comparable trial conditions before ranking the modeled energy use.
  5. Inspect the removal curve, exact target ledger and CSV report.

The Formula

The mathematical logic powering this calculation is:

Set a daily water-removal target independently of the logged trials. Enter it in liters or US liquid pints. A US liquid pint is one eighth of 231 cubic inches, with 25.4 millimeters per inch. That gives exactly 0.473176473 L per US liquid pint. All comparisons use liters internally.

For each trial record elapsed powered hours and water collected. Include cycles and standby within that timed window. Divide collected liters by elapsed powered hours for the observed removal rate. Multiply this rate by the available daily powered hours to estimate that day's collected water under comparable conditions. Divide the daily target by a positive removal rate for the powered hours required. Zero measured removal gives no finite target time.

A positive meter reading for the same elapsed window gives observed L/kWh and average kWh per powered hour. Estimated energy to reach the target is that average multiplied by the required powered hours. It is reported when the target fits in the available hours. Apply the entered USD/kWh tariff to estimate the energy charge. The comparison uses exact rational arithmetic and displays the charge rounded to cents. A meter reading of zero or an unrecorded reading leaves the water calculation available.

The energy comparison assumes the trials ran under comparable conditions and the entered daily water target is the same. Logged trends can change with the moisture supply and room conditions over time. Laboratory capacity in pints per day and integrated energy factor in L/kWh use prescribed test conditions. The trial readings reflect the logged interval. The worksheet uses an independently specified target and excludes humidity forecasting, remediation and room-size recommendations.

Worked Example

If you input:

  • Daily target: 6 L
  • Trial A: 4 L in 8 h, 2 kWh, 14 daily hours available
  • Trial B: 7.5 L in 10 h, 1.5 kWh, 6 daily hours available

Result:

Trial A reaches 6 L in 12 powered hours at 3 kWh. Trial B needs only 8 hours to reach 6 L but its entered six-hour window supports 4.5 L. With 10 hours available to Trial B, both can meet the target and Trial B uses 1.2 kWh.

Frequently Asked Questions

Do I enter the running compressor time or the elapsed test time?

Use the elapsed powered window that matches the collected water and meter readings. This keeps cycling and included standby in the same measurement basis.

Can a trial collect water without a meter reading?

Enter the measured collection and elapsed hours. The water target check works without energy, and a positive meter reading is needed for an electricity comparison.

Does a 30-pint nameplate predict 30 pints in my space?

Capacity is a lab result for a specified 24-hour test. Use collected water from your own timed trial for the modeled rate.

Why can the lower-energy option fail the daily target?

Its available powered hours may be too short. The target check uses the observed removal rate and available hours first, then compares feasible metered plans.

Where does the daily water target come from?

Enter an established planning target in liters or US liquid pints per day. This worksheet quantifies whether the logged rate and schedule reach it.