Chimney Masonry Joint Scope & Repair Quote Planner
Check which measured chimney joints each written repair quote covers. Compare two proposals by face, including intersecting joints, coverage depth and centerline feet. Keep incomplete prices separate from complete quotes and identify missing work before comparing totals.
Compare chimney joint scope and repair quotes
Map measured mortar joints and compare what each written repair proposal covers.
Measured scope and quote totals
- Required joint footprint
- 35.75 in²
- Required joint volume
- 29.875 in³
Proposal A
- Written charges
- $879.00 known
- Missing required volume
- 5.875 in³
- Quoted joint volume
- 33 in³
- Extra quoted volume
- 9 in³
- Quoted joint footprint
- 42 in²
- Measured centerline
- 7 ft
Proposal B
- Written charges
- $1,100.00
- Missing required volume
- 0 in³
- Quoted joint volume
- 29.875 in³
- Extra quoted volume
- 0 in³
- Quoted joint footprint
- 35.75 in²
- Measured centerline
- 6 ft
Review the missing required joint scope before comparing complete prices.
Measured joint coverage by face
Both diagrams share one scale. The hatched areas show where quoted depth falls below required depth.
Front face · 48 in wide × 24 in high
- Missing required volume
- 5.875 in³
- Extra quoted volume
- 0 in³
- Quoted footprint
- 24 in²
- Quoted volume
- 24 in³
Front face · 48 in wide × 24 in high
- Missing required volume
- 0 in³
- Extra quoted volume
- 0 in³
- Quoted footprint
- 35.75 in²
- Quoted volume
- 29.875 in³
Edit faces, strips and quotes
Measured faces
Use one rectangle per professionally measured face. The lower-left corner is the origin. Move assigned strips to another face before deleting their original face.
Measured joint strips
For a horizontal strip, axis start is measured from the left and band offset from the bottom. For a vertical strip, start is measured from the bottom and offset from the left. Measure offset to the near edge of the band. If a quote gives a different length, width or depth for a required joint, enter the quoted band as a separate optional strip.
Proposal A written scope
Proposal B written scope
Written repair charges and export
Use Included for a charge covered elsewhere in the written total. An unpriced line keeps the total incomplete. Joint work can use measured centerline feet or an entered fixed amount.
Proposal A
- Joint work · $22.00/ft
- $154.00
- Crown or cap
- Unpriced
- Flashing
- Included
- Access and setup
- $725.00
Proposal B
- Joint work · $25.00/ft
- $150.00
- Crown or cap
- $200.00
- Flashing
- Included
- Access and setup
- $750.00
View selectable CSV
How to use this calculator
- Enter the measured dimensions of each masonry face. Identify the required joint strips from the documented professional scope.
- Enter each strip’s face, direction, axis start and length, band offset and width, and documented depth.
- Select the strips included in each written quote. Add optional strips for quoted bands that differ from the documented requirements.
- Compare missing joint volume by face. Then add each written charge and review which costs remain open.
- Download the measured strips, coverage coordinates, and written quote ledger as CSV.
The Formula
The mathematical logic powering this calculation is:
Use rectangular measured faces and rectangular joint bands. Enter each strip from the lower-left origin. A horizontal strip starts along the width and offsets up the height. A vertical strip starts up the height and offsets along the width. For both orientations, the offset is the near edge of the band. Mark the strips in the documented required scope as Required. Record a differing quoted dimension by entering a separate Optional strip and selecting that strip for the applicable proposal.
Every strip boundary divides its face into rectangular cells. For the required and quoted measurements separately, the greatest applicable depth in each cell determines the volume. Multiplying cell area by depth and summing the cells avoids counting the same physical volume twice at a crossing. Footprint totals sum only cells with positive depth. Required gap is cell area times any positive required-minus-quoted depth. Extra scope is cell area times any positive quoted-minus-required depth. Sum each independently across all faces, so a wider scope on one face never offsets a missing section on another.
When a written quote uses linear feet, measure the union of selected centerline intervals that share a face, orientation and exact centerline. Distinct centerlines and perpendicular strips each contribute their own length. Convert the total inches to feet and multiply by the entered rate. A fixed joint price uses the written amount. Crown or cap, flashing, and access and setup each have an independent status and amount. Included adds zero incremental cost, and an unpriced item keeps the total open. Extended charges round to cents with half-up ties. The quote comparison uses complete prices whose coverage meets the entered required volumes in each cell.
The worksheet supports one to four faces, one to twenty-four measured strips, up to 240 inches per face dimension, and documented strip depths from 0.001 to 6 inches. Dimensions use up to three decimal places. The quantities describe measured joint geometry and the entered scope, and the worksheet uses no default inspection, suitability or operating criteria.Worked Example
If you input:
- Measured front face: 48 × 24 in, with a 48 × 0.5 in horizontal strip at 1 in depth and a 24 × 0.5 in vertical strip at 0.5 in depth.
- Proposal A: Front horizontal and optional 36 in side strip. Joint work is $22/ft, access is $725, and crown is unpriced.
- Proposal B: Both required front strips. Joint work is $25/ft, access is $750, and crown is $200.
Result:
The required crossing covers 35.75 in² and 29.875 in³. Proposal A quotes 33 in³ but leaves 5.875 in³ of required scope open and has $879 in known charges. Proposal B covers the full measured required volume and totals $1,100.
Frequently Asked Questions
Why does a larger quoted volume still show a required gap?
The worksheet compares depth at the same position on the same face. A quote can cover extra area while omitting another required strip or part of its depth.
How are crossing mortar joints counted?
The highest entered depth covers the rectangle where two strips cross. The shared footprint and its physical volume are each counted once.
What is the difference between joint centerline feet and footprint?
Centerline feet measure quoted runs along their length. Footprint measures the covered surface area, including band widths. A crossing may have two centerline runs over one shared footprint.
Is the known subtotal a complete quote?
It sums the written charges available so far. Once every charge is priced or explicitly included and at least one has a price, the full written total appears.
What if one quote includes more of a joint’s depth than the other?
Enter a distinct optional strip with the reported dimensions and assign it to that proposal. The worksheet compares the two measured footprints and depths.
Similar Calculators
Brick Masonry Calculator
Estimate brick count, mortar volume, wall area, waste allowance, and masonry material cost.
Roof Replacement Cost & Quote Comparison Calculator
Compare roof replacement quotes, scope gaps and decking repair allowances. See when prices cross, how many repairs fit your budget, and export the full comparison.
Foundation Repair Quote & Depth Planner
Compare foundation repair quotes across supplied pier depths. Audit included-depth allowances, per-pier billing increments, fixed scope and missing prices.