Blown-In Cellulose Insulation Calculator & Depth Audit

Record the label's initial and settled thickness minimums and its bag minimum. Compare the lowest recorded readings in each measured zone to the corresponding threshold, and find areas where measurements are missing or below the stated minimum.

Cellulose records

Check blown-in cellulose depth and bag records

Entered product label

Copy the applicable label row and record only the material installed in these zones. Leave installed quantity blank until verified.

Nonoverlapping measured zones

Use the lowest recorded sample in each zone at each phase. Leave unreported depths blank.

Zone 1
Zone 2
Zone 3
At least one recorded check is below its entered minimum.
Material minimum for entered area
36.50 bags
1,000 ft² measured
Verified installed quantity
36.50 bags
Meets entered minimum

Survey area by depth result

Bars group the entered zone areas by their lowest reported reading.

Initial survey

Meets entered minimum
740 ft²
Below entered minimum
260 ft²
Awaiting record
0 ft²

Settled survey

Meets entered minimum
740 ft²
Below entered minimum
0 ft²
Awaiting record
260 ft²

Lowest depth by zone

Marker at 8.90 in, the entered initial minimum.

Zone 1 · 440 ft²8.90 in
Zone 2 · 300 ft²9.10 in
Zone 3 · 260 ft²8.80 in
Review zones and exact survey CSV

How to use this calculator

  1. Copy the minimum initial and settled depths and the bags per 1,000 ft² for the selected label row.
  2. Enter distinct measured areas and their lowest depth readings. Leave records blank when they are unavailable.
  3. Enter the verified amount actually installed in bag equivalents for the same areas.
  4. Review the initial and settled plots and export the zone and material audit.

The Formula

The mathematical logic powering this calculation is:

Use the product's label for one application and framing basis. Enter its minimum initial depth, minimum settled depth and minimum bags per 1,000 ft². For each distinct measured zone, enter net area and the lowest measured depth in that zone for each phase. A phase reading at or above its corresponding threshold meets that entered depth check. A reading below the threshold is recorded as low. A blank remains pending. Zero is an entered measurement.
Sum the zones without overlapping area. Exact minimum installed bag equivalents equal the total measured area times the entered label rate divided by 1,000. Use the verified installed bag equivalents for this area and product. If an installer documented a fractional bag equivalent, enter the confirmed quantity to two decimals. Purchased or delivered bags may include material left unused. Compare the exact input-derived minimum against the verified installed total without rounding up a fraction. A blank installed quantity stays pending.
The chart groups the entered zone areas by their reported low, meets or pending status for each phase. Low values take precedence over pending in the overall result. This audit applies the entered minimums to the information supplied and does not estimate unsampled depth or material distribution. It does not choose a product, R-value, climate requirement, required inspection method or installation procedure.
Use one to six nonoverlapping zones with 0.01–100,000 ft² each. Product depths range from 0.01–48 in and observed depths 0–48 in. Enter 0.01–250 bags per 1,000 ft² and 0–25,000 verified bag equivalents, with up to two decimals. The worked example uses one published loose-fill row adjusted for the specified framing. Use the product and application data for your own scope.

Worked Example

If you input:

  • Example label: Loose-fill 8.90 in initial, 8.30 in settled and 36.50 bags per 1,000 ft².
  • Areas: 440, 300 and 260 ft².
  • Recorded depths: 8.90, 9.10 and 8.80 in initially. 8.30 and 8.40 in settled with one pending zone.
  • Installed quantity: 36.50 bag equivalents.

Result:

The entered material meets the exact minimum of 36.50 bags. The 260 ft² zone records an initial depth 0.10 in below the entered minimum. Its settled reading is pending.

Frequently Asked Questions

Can adequate total bags make up for a low depth reading?

The worksheet reports the bag quantity and zone readings separately. A low reading remains flagged even when total installed material meets the entered minimum.

Why does initial depth differ from settled depth?

Manufacturers can list separate minimums for the initial and later settled phases. Use the matching row and compare the measurement made for each phase.

Can I use a purchase receipt for the installed quantity?

Use the verified amount installed in the entered areas. Purchased material may include leftover stock or material used elsewhere.

Does a complete audit verify the entire attic?

The result covers the entered zone observations and quantities. It does not extrapolate between sample locations or confirm a label rating or code compliance.