Camshaft Timing & Valve Overlap Planner

Compare four-stroke cam cards or measured valve events on a shared crank-angle axis. Enter the opening and closing angles with each card’s stated checking lift and measurement basis. Read the duration above that threshold, and see whether the intake and exhaust windows overlap, touch or have a gap near top dead center.

Cam card timing

Compare camshaft events at the stated checking lift

Valve timing summary

Plan A

Crane 113801

0.05 in tappet lift

Exact touch

  • 222° intake
  • 234° exhaust

Plan B

Crower 60919

0.05 in tappet lift

11.5° overlap

  • 231° intake
  • 240° exhaust

Matched checking lift

B − A intake duration
+9°
B − A exhaust duration
+6°
B − A signed overlap or gap
+11.5°

Matched checking lift. Plan A Exact touch. Plan B 11.5° overlap.

Cam card inputs

Enter a positive angle for the printed before/after direction. Use a minus sign for the opposite direction at that dead center. Copy the checking lift and basis from each card.

Plan A
Plan B

Valve event windows

720° crank cycle

The bars mark the entered threshold windows. Angles are crank degrees from the transition TDC.

  • Intake window
  • Exhaust window

Plan A · Crane 1138010.05 in tappet lift

Plan B · Crower 609190.05 in tappet lift

-360°-180°0°+180°+360°
Transition near top dead center

The dashed reference is transition TDC. A bracket shows where the windows overlap or where neither reaches the checking lift.

  • Intake window
  • Exhaust window

Plan A · Crane 1138010.05 in tappet liftExact touch

Plan B · Crower 609190.05 in tappet lift11.5° overlap

-10°0°+10°

Cam card worksheet

Windows and durations in crank degrees relative to the exhaust-to-intake TDC
Card and liftIntake windowExhaust windowTransition
Plan A · Crane 113801

0.05 in tappet lift

-2° to +220°

222° duration

-236° to -2°

234° duration

Exact touch

-2°

Plan B · Crower 60919

0.05 in tappet lift

-7.5° to +223.5°

231° duration

-236° to +4°

240° duration

11.5° overlap

-7.5° to +4°

Download cam card CSV
Open selectable cam card CSV

How to use this calculator

  1. Enter a card label and the published or measured checking lift in inches. Choose the basis at the tappet or at the valve.
  2. Copy the four event angles. Use the printed direction for positive values and a minus sign for the opposite direction at that dead center.
  3. Review intake and exhaust durations, and find the overlap, exact touch or gap around the transition TDC.
  4. Use the 720° diagram for event sequence and the TDC close-up to see the exact transition window.
  5. Compare matching-basis deltas if available, or download both cards and their independent event windows.

The Formula

The mathematical logic powering this calculation is:

This worksheet draws the threshold events for one cylinder of a four-stroke cycle. Crank angle 0° is the top dead center between the exhaust and intake strokes. The bottom dead centers immediately before and after it are −180° and +180°. The previous and next top dead centers are −360° and +360°.

Enter the four signed numbers IO, IC, EO and EC using the before/after directions printed by the fields. A negative number changes the direction around the same dead center. The shared-axis intake window runs from −IO to 180° + IC, and the exhaust window runs from −180° − EO to EC. Opening-to-closing duration is end minus start. Within the supported range, the signed transition is EC + IO. A positive value gives overlap, a negative value gives a gap of its absolute size, and zero marks exactly touching endpoints.

A checking lift is the threshold at which the recorded events are measured. COMP Cams documents that different checking lifts can mark different events on the same cam. A tappet reading and a valve reading refer to different places in the mechanism. The worksheet keeps each card's own window and displays B − A differences only when the stated basis and numeric checking lift match. It performs no conversion between bases. Use the published degreeing or advertised threshold exactly as specified on the card.

Each signed input extends from −90° to 90° from the named dead center. This local range keeps the intake and exhaust windows on their respective side of the cycle. Begin and end each window at distinct points with positive duration. Both event angles and the checking lift accept up to four decimal places. Checking lift accepts 0.0001–1 in. The calculation uses exact ten-thousandths for the entered values. The close-up shows the same geometry as the broad view at a shorter scale.

The tool represents only the entered timing intervals at the stated threshold. It does not estimate lift curves, maximum-lift position, lobe separation, hardware clearance, installation compatibility, operating performance or suitable cam selection.

Worked Example

If you input:

  • Plan A checking lift: Crane 113801, 0.050 in tappet.
  • Plan A signed events: 2° BTDC, 40° ABDC, 56° BBDC, −2° signed ATDC (2° BTDC).
  • Plan B checking lift: Crower 60919, 0.050 in tappet.
  • Plan B signed events: 7.5° BTDC, 43.5° ABDC, 56° BBDC, 4° ATDC.

Result:

Crane shows 222° intake, 234° exhaust and an exact touch at 2° BTDC. Crower shows 231° intake, 240° exhaust and 11.5° overlap from 7.5° BTDC to 4° ATDC. At the shared checking lift, the B − A duration differences are +9° intake and +6° exhaust.

Frequently Asked Questions

What is a checking lift?

It is the specified movement at which an opening or closing is recorded. A card may give threshold events at both a lower advertised checking lift and a separate degreeing lift.

Why do two cards with the same number need the same lift basis?

Tappet lift and valve lift measure movement at different points in the mechanism. This worksheet compares differences only when the same point and numeric threshold are documented.

How do I enter an exhaust closure before TDC?

The Exhaust closes field is signed ATDC. A closure two degrees before TDC is entered as −2.

What does exact touch mean?

The intake opening and exhaust closing reach the stated threshold at the same crank position. There is no positive overlap or gap at that threshold, even if the position is before or after TDC.

Can the overlap occur entirely before top dead center?

Yes. The close-up and worksheet show the actual interval and its endpoints relative to transition TDC.

Is the chart a lift curve?

The bars show threshold windows only. Four events do not determine peak lift or how the valve moves between the two threshold crossings.

Similar Calculators