Electric Baseboard Heater Runtime & Cost Calculator

Enter two rated loads and two sets of observed operating windows. Compare exact energy costs at a supplied peak and off-peak rate. Inspect each period’s active loads and compare simultaneous watts with your entered planning limit.

Heater runtimes and tariff bands

Compare electric baseboard costs by schedule

Schedule B has the lower modeled energy cost.
Schedule A energy cost
$45.00
5 kWh/day · 2,500 W highest combined
Schedule B energy cost
$28.80
5 kWh/day · 1,500 W highest combined
Simultaneous heater load across the day

Shading marks the peak rate. Both plots share a scale up to 2,500 W. The vertical guide marks 18:00. The dotted line shows the entered limit.

Schedule A

2,500 W at 18:00 · Peak
00:0012:0024:00

Zone 1 and Zone 2 on

Schedule B

1,000 W at 18:00 · Peak
00:0012:0024:00

Zone 2 on

Heater loads and one repeated day

24-hour clock.

24-hour clock.

Leave blank for no comparison limit.

Schedule A windows
Window 1
Window 2
Schedule B windows
Window 1
Window 2
Review band usage and exact CSV
Schedule A · peak per day
5 kWh
Off-peak per day
0 kWh
Zone 1 runtime
120 min
Zone 2 runtime
120 min
Schedule B · peak per day
2 kWh
Off-peak per day
3 kWh
Zone 1 runtime
120 min
Zone 2 runtime
120 min

How to use this calculator

  1. Enter the watts of two baseboard groups from your measured or documented full-load readings.
  2. Enter local-clock peak hours, both rates and the number of similar days. Use a zero rate when the documented energy charge is zero.
  3. Enter two sets of operating periods for the same loads. Select a plot and move across the day to see concurrent loads and rate bands.
  4. Compare repeated-day energy cost and highest simultaneous heater watts. Download the exact band and segment ledger.

The Formula

The mathematical logic powering this calculation is:

Use a representative 24-hour operating record with two electric heater loads. A listed heater draws its entered watts when on and zero when off. A window includes its start minute and ends before its end minute. Midnight is 00:00 at the start of the day and 24:00 at its end. Split a heater window that crosses midnight into two rows. Overlapping windows for the same heater count its load only once. Simultaneous heaters add their watts.
A peak band may cross midnight when its start clock is later than its end clock. The rest of the day is off-peak. Split every operating interval at tariff and load changes. Watt-minutes equal active watts × segment minutes. Divide watt-minutes by 60,000 for kWh. Multiply each rate by its band’s energy and sum. Multiply the representative day’s exact cost by the entered number of days, then round once to cents, with a half cent rounded up. Separately compare the highest simultaneous heater watts with the optional numeric limit. Equality passes.
Use 0–25,000 whole watts per zone, up to 14 operating windows per schedule, 1–366 repeat days and rates 0–10 USD/kWh with up to four decimals. The optional limit accepts 0–50,000 whole watts. The model uses supplied operating windows and rates. It does not predict thermostat duty cycle, heat loss, comfort, site wiring, breaker or equipment suitability, other circuits’ demand, demand charges, taxes, utility meter intervals or billing fees.

Worked Example

If you input:

  • Heaters: 1,500 W and 1,000 W
  • Peak band: 16:00–21:00 at $0.30/kWh, otherwise $0.12/kWh
  • Schedule A: Zone 1 runs 17:00–19:00, zone 2 runs 18:00–20:00
  • Schedule B: Zone 1 runs 14:00–16:00, zone 2 runs 17:00–19:00
  • Modeled days and limit: 30 days and 2,500 W

Result:

Both schedules use 5 kWh per day. A costs $45 over 30 days and reaches 2,500 W. B costs $28.80 and reaches 1,500 W. Lowering the entered limit by 1 W rules out A.

Frequently Asked Questions

Is the highest simultaneous value my metered demand charge?

It is a sum of entered heater loads at a reported minute. Actual metered demand can use averaged intervals and include other loads.

What if the same zone is listed twice at the same time?

The union of those windows turns that zone on once at that minute. Different zones add together.

Can the peak rate start late at night and end next morning?

Yes. Enter a later start and earlier end for that band. Individual heater windows crossing midnight still use two rows.