Young’s Modulus & Stress–Strain Fit Calculator
Enter force and extension observations for a specimen with measured starting dimensions, or use stress and strain you already calculated. Select two observation windows to compare least-squares and endpoint chord slopes. See which readings drive the difference and inspect a fitted stress within each observed range.
Compare two stress–strain fit windows
Normalize specimen readings or enter measured stress and strain. Inspect slope, chord and residuals in two chosen ranges.
Edit measured readings and units
Choose measured fit windows
Use inclusive row numbers from your readings. An independently identified elastic range is needed to interpret its slope as Young’s modulus.
Window B slope minus Window A slope -85 GPa
Stress–strain observations and fit windows
- ● Measured readings
- Window A fit
- Window B fit
Reading 1
0 µε at 0 MPa
Window A residual 0 MPa
Window A fit audit
- Observed strain range
- 0 µε to 200 µε
- Observed stress range
- 0 MPa to 40 MPa
- Endpoint chord
- 200 GPa
- Fitted stress intercept
- 0 MPa
- Residual RMSE
- 0 MPa
- R²
- 1
- Fitted stress at 200 µε
- 40 MPa
Window B fit audit
- Observed strain range
- 200 µε to 500 µε
- Observed stress range
- 40 MPa to 75 MPa
- Endpoint chord
- 116.666667 GPa
- Fitted stress intercept
- 18.5 MPa
- Residual RMSE
- 1.36930639 MPa
- R²
- 0.988785047
- Fitted stress at 200 µε
- 41.5 MPa
Normalized readings and residuals
Residual is measured minus fitted stress. An empty cell is outside that fit window.
| Reading | Strain (µε) | Stress (MPa) | A fit (MPa) | A residual (MPa) | B fit (MPa) | B residual (MPa) |
|---|---|---|---|---|---|---|
| 0 µε | 0 | 0 | 0 | |||
| 100 µε | 20 | 20 | 0 | |||
| 200 µε | 40 | 40 | 0 | 41.5 | -1.5 | |
| 300 µε | 55 | 53 | 2 | |||
| 400 µε | 65 | 64.5 | 0.5 | |||
| 500 µε | 75 | 76 | -1 |
Show selectable CSV
How to use this calculator
- Choose force and extension readings or measured stress and strain.
- For force and extension, enter the original gauge length and cross-sectional area. Check the unit labels.
- Enter the observations in test order and select the first and last row for each comparison window.
- Compare fitted and chord slopes, residuals and the optional fitted stress at a shared strain.
- Export the normalized observations and fit audit for further review.
The Formula
The mathematical logic powering this calculation is:
Engineering stress σ equals measured force F divided by original cross-sectional area A. Engineering strain ε equals gauge extension ΔL divided by original gauge length L. Use measured extension over the stated gauge. These formulas keep the original dimensions for every observation.
Select two inclusive ranges of entered row numbers. Each window uses equal-weight ordinary least squares with a fitted intercept. Slope is Σ(ε − mean ε)(σ − mean σ) divided by Σ(ε − mean ε)². Intercept is mean σ minus slope times mean ε. A positive fitted slope in an independently identified linear elastic window can estimate Young’s modulus. The workspace displays the model slope for any supported window and leaves the window choice to the user.
The endpoint chord uses (last stress − first stress) divided by (last strain − first strain) in entered order. Equal endpoint strains prevent a chord calculation even when other observations identify an OLS slope. A window with all strains equal cannot identify a slope.
Residual equals measured stress minus fitted stress. RMSE uses the square root of the mean of squared residuals in that window. R² is one minus residual sum of squares divided by total stress sum of squares around the mean. Constant stress leaves R² undefined. An optional strain probe uses the fitted line only from the minimum through the maximum observed strain in each window, endpoints included.
Stress is normalized to MPa, strain to a dimensionless ratio, and slope is displayed in GPa. One inch is exactly 25.4 mm and one pound-force is 4.4482216152605 N at standard gravity. A percent strain is 1/100 and a microstrain is 1/1,000,000. Enter 2 to 14 readings, strain ratios between −100 and 100, and stresses between −10¹² and 10¹² MPa. In specimen mode, the initial gauge and area each range from 10⁻¹² to 10¹² in mm and mm². The worksheet keeps rational inputs, conversions and fits exact. RMSE and plot labels are rounded for display.Worked Example
If you input:
- Measurement basis: Force and extension
- Initial gauge length: 100 mm
- Initial cross-sectional area: 10 mm²
- Extension readings: 0, 0.01, 0.02, 0.03, 0.04, 0.05 mm
- Force readings: 0, 200, 400, 550, 650, 750 N
- Window A: Rows 1–3
- Window B: Rows 3–6
- Strain probe: 200 µε
Result:
Window A fits 200 GPa, with a 200 GPa chord and zero residual error. Window B fits 115 GPa, with a chord of about 116.666667 GPa. At 200 µε the two fitted stresses are 40 and 41.5 MPa.
Frequently Asked Questions
Why might the two windows produce different slopes?
Different portions of a trace can show different response or measurement scatter. Compare the displayed residuals and apply your independently chosen elastic window.
Why is the chord unavailable if the least-squares fit works?
The chord needs distinct strain values for the first and last readings. The least-squares fit can use any distinct strains within the selected window.
What does a zero or negative fitted slope mean?
It describes the selected recorded data under the entered sign and window convention. An elastic modulus estimate requires a suitable range of measurements with a positive slope.
What units do I use for the two input modes?
Force and extension accepts newtons, kilonewtons or pound-force, with a shared length unit for extension and gauge length and its square for area. Measured stress and strain accepts MPa, GPa or ksi and strain as a ratio, percent or microstrain.
Why does a probe sometimes show no fitted stress?
Each window reports its fitted stress only between its minimum and maximum measured strain. A probe can be within one window and outside the other.
Similar Calculators
Linear Regression Calculator
Fit a least-squares line, inspect scatter and residual plots, and calculate Student-t confidence and prediction intervals. Paste paired data and export the full ledger.
Beam Response Calculator
Calculate beam reactions, shear force, bending moment, slope and deflection. Inspect load jumps and analytical extrema for simple supports or a cantilever.
Uncertainty Propagation Calculator
Propagate independent measurement uncertainties through sums, products and ratios. Compare contributions, expanded uncertainty and input improvement scenarios.
Hardness Conversion Calculator & Reference Curve Audit
Estimate cross-scale hardness using your documented same-material reference pairs. Compare two reading ranges and see where they sit against a target band.
Tensile Strength & Coupon Proof Stress Calculator
Compare engineering tensile strength and offset proof stress from two recorded coupon traces. Inspect the first pre-peak crossing and exact thresholds.