Uptime & Downtime Budget Planner

Enter one UTC observation window, your time-based availability target and a log of outage or exclusion intervals. Compare two interpretations of the same record. See the counted downtime, denominator and budget on each side, then review the normalized intervals on a shared timeline.

Time-based availability

Compare uptime and downtime allowances

Use one UTC observation and a collected interval log. See how counted downtime and its allowance change when marked windows are excluded.

UTC observation and target

Availability and downtime budget

Observation 30d · Target 99.9%

Marked exclusions 30m · Outage inside exclusions 20m

All elapsed time: 6m 48s over budget. Exclude marked windows: 13m 10.2s budget remaining.

All elapsed time

99.884259%

6m 48s over budget

Eligible observation
30d
Counted downtime
50m
Allowable downtime
43m 12s

Exclude marked windows

99.930507%

13m 10.2s budget remaining

Eligible observation
29d 23h 30m
Counted downtime
30m
Allowable downtime
43m 10.2s

Enter outages and exclusion windows

If a measured outage and an exclusion overlap, enter both intervals. Use UTC for the date and time in every row.

Interval 1
Interval 2
Interval 3
Interval 4

Counted downtime versus allowance

Filled bars are counted downtime. The outlined marker is the allowance. Both policies share a 0 to 50m scale.

All elapsed time

50m counted · 43m 12s allowed

Exclude marked windows

30m counted · 43m 10.2s allowed

Observation timeline

Both lanes use the same UTC time scale. A vertical mark shows where counted downtime starts.

All elapsed time

Exclude marked windows

2026-11-01 00:00 UTC2026-12-01 00:00 UTC
  • Up
  • Counted downtime
  • Excluded

Interval ledger and export

The ledger clips each authored interval. Overlaps can appear in multiple rows here and are counted once in the budget.

Open interval ledger
Recorded intervals and clipped duration
IntervalTypeStart UTCEnd UTCClipped duration
1Observed outage2026-11-03 03:002026-11-03 03:3535m
2Observed outage2026-11-03 03:152026-11-03 03:4025m
3Observed outage2026-11-12 14:002026-11-12 14:1010m
4Excluded window2026-11-03 03:202026-11-03 03:5030m
Download uptime budget CSV
Open CSV text

How to use this calculator

  1. Set the UTC observation start, end and time-based availability target.
  2. Enter each outage interval. Add exclusion rows separately for the comparison rule that omits them.
  3. Review eligible time, counted downtime and remaining allowance under both policies.
  4. Focus the timeline on a specific interval to see overlaps, then inspect the ledger or download its CSV.

The Formula

The mathematical logic powering this calculation is:

Enter one observed period in UTC, up to 366 days, and a time-based percentage target. Each timestamp is a whole second; enter minutes or seconds. The interval includes the opening instant and stops before the ending instant. Enter observed outage intervals for complete unavailability. Enter separate exclusion intervals for times intentionally removed under the second accounting rule. An exclusion alone does not mark observable downtime under the first rule. When a known outage overlaps an excluded window, enter both observations.

Clip each row to the observation window. Count the union of observed outage intervals, counting overlapping or adjacent outage seconds once. Do the same for explicitly excluded intervals. All elapsed time uses the whole observation as its denominator and the full outage union as downtime. Exclude marked windows removes the exclusion union from the denominator and any outage seconds inside it from counted downtime. A fully excluded observation supplies no eligible denominator and no availability percentage.

For either eligible denominator T in seconds and counted downtime D, uptime fraction = (T−D)/T. Multiply by 100 for the availability percentage. Downtime allowance = T × (1−target/100). Signed remaining allowance = allowance − D. The target is met exactly at zero remaining allowance. A negative amount is the excess downtime. The target accepts six decimal places and arithmetic compares the exact decimal budget against the whole observed seconds. The Google SRE table gives a 30-day 99.9% example of 43.2 minutes when all elapsed time counts.

The timeline compares the same normalized seconds under both policies, and the ledger lists clipped durations plus the merged segments in the CSV. A row outside the observation contributes no seconds. The worksheet models time-based availability, with all eligible time outside entered outages treated as up. Partial traffic failures, request-based service objectives, missing telemetry and contract-specific credits require other information. Select the rule appropriate to your stated interval accounting.

Worked Example

If you input:

  • Observed span: 2026-11-01 00:00 through 2026-12-01 00:00 UTC; 99.9% target.
  • First outage cluster: Nov 3 at 03:00–03:35 and 03:15–03:40 UTC. The overlap yields a 40-minute union.
  • Other outage and exclusion: Nov 12 at 14:00–14:10 UTC. Exclude Nov 3 at 03:20–03:50 UTC in the second view.

Result:

All elapsed time counts 50 minutes of downtime and is 6m 48s over its 43m 12s allowance. The excluded-windows policy removes 30 minutes of eligible time and 20 minutes of overlapping outage, leaving 30 minutes counted and 13m 10.2s allowance available.

Frequently Asked Questions

What does the observation denominator mean?

It is the elapsed period under the first policy, or the elapsed period minus the union of marked exclusions under the second. Availability divides uptime by that policy’s eligible elapsed time.

How do overlapping or duplicate outages count?

They contribute their combined interval once. The worksheet computes the exact set of affected seconds before applying either policy.

Does every maintenance window count as an outage?

The entered outage rows identify periods of unavailability. An excluded interval changes the second policy’s accounting, even when there was no outage in that window.

Why does the second policy have a smaller budget?

It is based on its shorter eligible period. The second policy can have less counted downtime and a smaller total allowance at the same target.

Can a target use 100%?

Yes. Its permitted downtime is zero. If the eligible time was entirely up, that is exact equality. If no eligible time remains, availability and allowance are unavailable.

Can this calculate request success or SLA compensation?

The model uses elapsed time and recorded full outages. Request-based availability and contractual outcomes need additional data and terms.

Similar Calculators