Two-Stroke Oil Mix & Premix Planner
Plan a fresh two-stroke mixture or additions to known compatible contents. Choose a finished-mixture target or the total petrol component, enter the equipment-specified petrol:oil ratio, and compare the result with additional petrol, oil and usable container capacity. The component ledger accounts for every existing row instead of averaging its ratio. Separate petrol and oil charts, a feasible-volume explorer and exact CSV show what can actually be made by addition alone. A target that requires removing a component or exceeds stocks or capacity stays visibly infeasible. This is ideal additive-volume bookkeeping, not a test of fuel suitability. It cannot establish whether unknown, aged, contaminated or incompatible fuel is usable.
Two-stroke premix planner
Plan additions, compare batch sizes and check stocks and usable capacity.
For known, compatible, suitable ingredients only. The equipment manual determines the required ratio and approved ingredients. This calculation cannot make unknown, aged or contaminated fuel suitable. Enter usable capacity after allowing the applicable headspace.
Target & additional stocks
Petrol volume per 1 part oil; 1–200. Use the equipment manual.
Both include existing contents. Switching basis retains separate drafts.
Finished petrol-plus-oil volume; 0.001–1000 L.
Additional stock only; excludes existing contents.
Additional stock only, in millilitres.
Usable volume, not nominal brim capacity; 0.001–10000 L.
Existing known contents
Keep every entered component. Premix row volume is its total mixture, not just petrol. Leave this list empty for a fresh batch.
Up to 8 rows. Zero-volume premix rows still need a known ratio.
Requested target is feasible by addition alone.
Requested batch
5 L finished mixture
2.95074 L petrol + 49.25873 mL oil to add
Finished volume 5 L. Achieved petrol : oil ratio 50 : 1.
Remaining stocks: 1.04926 L petrol and 50.74127 mL oil. Free usable capacity: 0.5 L.
Existing contents: 2 L. Combined petrol : oil ratio 40 : 1. Additive-volume bookkeeping; no density or thermal correction.
Contents, target & capacity
Petrol and oil share the same volume scale below. Oil is amber with a dark outline; petrol is blue. The separate oil detail is magnified.
Existing contents: 1.95122 L petrol + 48.78049 mL oil
Requested target: 4.90196 L petrol + 98.03922 mL oil
Usable capacity: 5.5 L
Common scale: 0–5.5 L. Target leaves 0.5 L usable space.
Oil detail · separate scale
Existing oil: 48.78049 mL
Target oil: 98.03922 mL
Oil-detail scale: 0–98.03922 mL.
Component ledger & requested differences
Signed differences are diagnostic only. A negative component difference does not describe a removal recipe.
| Contents | Petrol (L) | Oil (mL) |
|---|---|---|
| Known 40:1 premix | 1.95122 | 48.78049 |
| Existing total | 1.95122 | 48.78049 |
| Requested components | 4.90196 | 98.03922 |
| Requested minus existing | 2.95074 | 49.25873 |
What can fit your ingredients?
Feasible finished volumes: 2.4878–5.5 L.
Minimum retaining all contents: 2.4878 L. Binding requirements: Retain existing oil.
Upper bound: 5.5 L. Binding limits: Usable capacity.
- Petrol stock
- 6.07024 L
- Oil stock
- 7.5878 L
- Usable capacity
- 5.5 L
Inspect the mathematical minimum
Minimum retaining all contents
0.4878 L petrol + 0 mL oil to add
Finished volume 2.4878 L. Achieved petrol : oil ratio 50 : 1.
Remaining stocks: 3.5122 L petrol and 100 mL oil. Free usable capacity: 3.0122 L.
Vertical scale: 0–3.44094 L.
Horizontal scale: 2.4878–5.5 L finished mixture.
Vertical scale: 0–59.06265 mL.
Horizontal scale: 2.4878–5.5 L finished mixture.
Selected candidate — does not change your requested target
0.4878 L petrol + 0 mL oil to add
Finished volume 2.4878 L. Achieved petrol : oil ratio 50 : 1.
Remaining stocks: 3.5122 L petrol and 100 mL oil. Free usable capacity: 3.0122 L.
102 canonical candidates: equally spaced across the feasible range, plus the exact requested target when feasible. Display values are rounded; CSV retains exact fractions.
| Finished (L) | Add petrol (L) | Add oil (mL) | Free capacity (L) |
|---|---|---|---|
| 2.4878 | 0.4878 | 0 | 3.0122 |
| 2.51793 | 0.51734 | 0.59063 | 2.98207 |
| 2.54805 | 0.54687 | 1.18125 | 2.95195 |
| 2.57817 | 0.5764 | 1.77188 | 2.92183 |
| 2.60829 | 0.60593 | 2.36251 | 2.89171 |
| 2.63841 | 0.63546 | 2.95313 | 2.86159 |
| 2.66854 | 0.66499 | 3.54376 | 2.83146 |
| 2.69866 | 0.69452 | 4.13439 | 2.80134 |
| 2.72878 | 0.72406 | 4.72501 | 2.77122 |
| 2.7589 | 0.75359 | 5.31564 | 2.7411 |
| 2.78902 | 0.78312 | 5.90626 | 2.71098 |
| 2.81915 | 0.81265 | 6.49689 | 2.68085 |
| 2.84927 | 0.84218 | 7.08752 | 2.65073 |
| 2.87939 | 0.87171 | 7.67814 | 2.62061 |
| 2.90951 | 0.90124 | 8.26877 | 2.59049 |
Keep the plan
Includes retained drafts, exact component ledger, requested diagnostics, bounds and every feasible candidate.
How to use this calculator
- Read the equipment manual for its required petrol:oil ratio, approved ingredients and handling directions. Enter the ratio as R in R:1; the default is illustrative.
- Choose finished mixture or total petrol as the target basis. Both include existing contents. For example, 5 L of petrol at 50:1 produces 5.1 L of mixture, whereas a 5 L finished mixture contains less than 5 L petrol.
- Enter additional petrol and oil stock separately from existing contents. Enter usable container capacity after the applicable headspace allowance, not the nominal brim volume.
- Add up to eight known-content rows. For premix, enter its total volume and known ratio; straight petrol and oil need no ratio. Leave the list empty for a fresh batch.
- Review requested feasibility, component differences, stock shortfalls and capacity overflow. Inspect the minimum retaining all contents and every binding upper limit.
- Explore feasible batches without replacing the requested target. Compare charts and table rows, then download the complete CSV or use Selectable CSV.
The Formula
The mathematical logic powering this calculation is:
Ratios are petrol volume : oil volume, R : 1. A 50:1 ratio means 50 volumes of petrol per 1 volume of oil, not oil equal to 1/50 of finished mixture. For a premix row with total volume V and ratio r, petrol F = Vr/(r+1) and oil O = V/(r+1). Straight petrol contributes (V,0); straight oil contributes (0,V). Sum row components to F0 and O0. Combined ratio is F0/O0 when O0 is positive; never average the row ratios.
For target ratio R, petrol fraction a = R/(R+1) and oil fraction b = 1/(R+1). With finished-mixture target T, required components are aT and bT. With a total-petrol target P, finished volume T = P/a; P includes existing petrol. Additional component differences are dF = aT−F0 and dO = bT−O0. An addition-only recipe requires both differences to be nonnegative, sufficient additional stock and T no greater than usable capacity. Negative differences are diagnostic excesses, not removal instructions.
The minimum finished volume retaining all contents is Tmin = max(F0/a, O0/b). With additional petrol stock SF, additional oil stock SO in litres and usable capacity C, Tmax = min((F0+SF)/a, (O0+SO)/b, C). All exactly tied constraints are retained. Tmin > Tmax means no feasible interval; equality gives one feasible volume. An interval [0,0] permits only an empty batch. The minimum itself may still exceed stocks or capacity and is checked explicitly.
Quantities and comparisons use exact rational arithmetic from unsigned decimal inputs with up to six places. Oil-stock input and oil-addition output are millilitres; other component volumes are litres. Candidate curves use 101 equally spaced feasible volumes, or one point for equality, and add the exact requested volume when feasible. Display numbers are rounded; CSV preserves reduced fractions. Volumes are assumed additive at the entered measurement conditions; no contraction, density, thermal expansion or uncertainty correction is included.Worked Example
If you input:
- Known existing contents: 2 L total premix at 40:1
- Requested target: 5 L finished mixture at 50:1
- Additional stocks: 4 L petrol and 100 mL oil
- Usable capacity: 5.5 L, after the applicable headspace allowance
Result:
The existing contents contain 80/41 L petrol and 2/41 L oil. A 5 L finished mixture at 50:1 needs 250/51 L petrol and 5/51 L oil. Add 6170/2091 L petrol, approximately 2.95074 L, and 103000/2091 mL oil, approximately 49.25873 mL. Stocks and capacity are sufficient, leaving 0.5 L usable space. The minimum retaining all contents is 102/41 L, approximately 2.48780 L, and capacity limits the maximum to 5.5 L. This example assumes known suitable compatible ingredients; it is not a universal equipment-ratio recommendation.
Frequently Asked Questions
Does 50:1 mean 100 mL oil in 5 L of finished mixture?
No. At 50:1, 5 L petrol needs 0.1 L oil, producing 5.1 L total under the additive-volume convention. A 5 L finished mixture instead contains 250/51 L petrol and 5000/51 mL oil, approximately 4.90196 L and 98.03922 mL. Choose the target basis explicitly.
Can I combine different known premix ratios?
The model accounts for each row’s petrol and oil separately, then sums the components. The result is not the arithmetic average of the ratios. This calculation applies only when the ingredients are already known, suitable and compatible; numerical ratio accounting cannot determine suitability.
Why does the tool refuse an addition-only recipe?
A target may contain less petrol or oil than the existing contents, exceed available additional stocks, exceed usable capacity, or fail several checks at once. The tool shows all applicable diagnostics and does not silently discard material or substitute another batch size.
What does the minimum retaining all contents mean?
It is the smallest mathematical volume at the target ratio whose petrol and oil components are each at least as large as the existing components. It still needs enough additional ingredients and capacity. When that minimum exceeds an upper limit, no feasible batch exists under the entered constraints.
Why can more than one ingredient limit the maximum batch?
Exactly matched petrol and oil stocks can be exhausted at the same finished volume, and capacity can equal that volume too. The model retains every exact tie so you can see whether increasing just one resource would leave another limit in place.
Does usable capacity equal the number printed on the container?
Not necessarily. Enter the usable volume after allowing the applicable headspace and following the equipment, container and ingredient handling directions. The calculator does not infer a safe fill level from a nominal container size.
Can this repair old, contaminated or unknown fuel?
No. The calculation only accounts for known volumes and ratios of suitable compatible ingredients. It cannot establish fuel age, composition, contamination, phase stability or equipment compatibility, and no numerical ratio adjustment proves that unsuitable fuel is safe to use.
Why do charts and CSV use different-looking numbers?
The chart and table display rounded values for readability. CSV keeps exact reduced fractions from the model and includes all candidate batches, drafts, diagnostics and limits. The two views use the same canonical results; a displayed rounded ratio is never used to recompute additions.
Similar Calculators
Fuel Cost Calculator
Calculate the fuel cost and consumption for any road trip or daily commute.
Motorcycle Gearing, RPM & Shift Planner
Compare motorcycle sprockets, tyre rollout and gearbox ratios. Plot RPM versus speed, wheel torque and shift recovery, inspect cruising RPM and export complete exact tables.
Ratio Calculator
Simplify ratios, find equivalent ratios, and solve for a missing value in a proportion.
