Sprinkler Layout Catch-Can & Coverage Audit Calculator
Compare sprinkler coverage at the same lawn catch-can positions before and after a change. Enter measured depths for both tests and their individual run times. View the original application rates, follow the low-quarter locations and see where coverage increased or decreased after normalizing for elapsed time.
Compare two measured sprinkler coverage maps
Use matched catch-can readings and run times to check distribution and find where the application rate changed.
Edit test durations and target
Edit sampled depths
Run A · 15 min
53.33333%
Below uniformity target
- Overall rate
- 0.75 in/hr
- Low-quarter rate
- 0.4 in/hr
Run B · 20 min
75%
Meets uniformity target
- Overall rate
- 0.6 in/hr
- Low-quarter rate
- 0.45 in/hr
B minus A · +21.66667 percentage points · +0.05 in/hr low quarter · -0.15 in/hr overall
Explore coverage by catch-can position
Rows run top to bottom. Columns run left to right. Select a cup or use arrow keys to move. Rates are inches per hour.
Darker shades show higher rates on a common scale. LQ marks low-quarter cups. Tie marks additional cups at the cutoff.
Cup A1
- Run A
- 0.1 in collected · 0.4 in/hr
- Selected low quarter
- Run B
- 0.15 in collected · 0.45 in/hr
- Selected low quarter
- B minus A
- +0.05 in/hr
Review sampled depths and export
| Cup | A depth (in) | B depth (in) | A rate (in/hr) | B rate (in/hr) | B − A (in/hr) | Low-quarter check |
|---|---|---|---|---|---|---|
| A1 | 0.1 | 0.15 | 0.4 | 0.45 | +0.05 | A · Selected low quarter B · Selected low quarter |
| A2 | 0.1 | 0.15 | 0.4 | 0.45 | +0.05 | A · Selected low quarter B · Selected low quarter |
| A3 | 0.21 | 0.21 | 0.84 | 0.63 | -0.21 | A · Outside low quarter B · Outside low quarter |
| A4 | 0.22 | 0.22 | 0.88 | 0.66 | -0.22 | A · Outside low quarter B · Outside low quarter |
| B1 | 0.1 | 0.15 | 0.4 | 0.45 | +0.05 | A · Selected low quarter B · Selected low quarter |
| B2 | 0.21 | 0.21 | 0.84 | 0.63 | -0.21 | A · Outside low quarter B · Outside low quarter |
| B3 | 0.22 | 0.22 | 0.88 | 0.66 | -0.22 | A · Outside low quarter B · Outside low quarter |
| B4 | 0.22 | 0.22 | 0.88 | 0.66 | -0.22 | A · Outside low quarter B · Outside low quarter |
| C1 | 0.21 | 0.21 | 0.84 | 0.63 | -0.21 | A · Outside low quarter B · Outside low quarter |
| C2 | 0.22 | 0.22 | 0.88 | 0.66 | -0.22 | A · Outside low quarter B · Outside low quarter |
| C3 | 0.22 | 0.22 | 0.88 | 0.66 | -0.22 | A · Outside low quarter B · Outside low quarter |
| C4 | 0.22 | 0.22 | 0.88 | 0.66 | -0.22 | A · Outside low quarter B · Outside low quarter |
How to use this calculator
- Record the same four-column sample positions for both runs. Use the same orientation when recording the data.
- Enter the number of rows, the two recorded test durations and the uniformity target you want to check.
- Copy each measured depth into the matching cup. Enter 0 for a confirmed dry cup.
- Compare the two rate layers or the signed change layer. Pick a cup to compare its measurements, hourly rates and low-quarter status.
- Open the ledger to compare exact values and export the full paired record.
The Formula
The mathematical logic powering this calculation is:
Use 12–24 matching catch positions, grouped into four columns and three to six rows. Every can has equal weight. Copy measured water depths in inches from comparable catch containers. Rate in inches per hour = depth in inches × 60 / entered run minutes. Rates normalize the two test durations before subtraction.
Sort each run's measured depths from low to high. With four columns and R rows, the low quarter is the lowest R observations. Calculate their arithmetic mean and the mean of all 4R observations. Low-quarter distribution uniformity = 100 × low-quarter mean / overall mean. The ratio is the same if you use normalized rates instead of depths. If every reading is zero, uniformity is unavailable. A zero cup reading is a measured value and participates in the lower quarter.
Uniformity meets the entered target when it is at or above it. Use exact fractions before display rounding. Run B minus Run A gives the percentage-point uniformity change and inches-per-hour change at each position. For tied depths at the end of the selected group, row-major order chooses the displayed contributors. Other cups with the same depth also receive a tied marker. The map shows samples on the entered grid. It does not infer coverage between cups.
Enter time from 0.1 to 600 min, depth from 0 to 24 in and target from 0 to 100%, each with up to four decimal places. Compare the same zone, container positions and exposure conditions. This worksheet evaluates observations against a caller-entered target. It does not select sprinkler heads, give a watering schedule, estimate plant needs or certify any audit protocol.Worked Example
If you input:
- Layout: Four columns by three rows with corresponding catch positions
- Run times: Run A 15 min, Run B 20 min
- Paired depths: A1, A2 and B1 change from 0.1 to 0.15 in. The other nine shared depths are three at 0.21 in and six at 0.22 in.
- Uniformity target: 75%
Result:
Run A reaches 53.33333% and Run B reaches exactly 75%. The low-quarter rate rises from 0.4 to 0.45 in/hr. Lowering Run B's A1 by 0.001 in yields about 74.86453%, below the entered threshold.
Frequently Asked Questions
Is low-quarter distribution uniformity the percentage of the lawn that was watered?
It is the low-quarter average catch divided by the overall average catch. It measures relative uniformity in the sampled grid.
Why can uniformity improve when the overall application rate falls?
The low quarter and the overall mean can move in opposite directions. In the example the overall rate falls from 0.75 to 0.6 in/hr while the low-quarter rate rises from 0.4 to 0.45 in/hr.
Can I compare two runs with different durations?
Yes. Use the measured durations to compare hourly rates. The worksheet assumes each run's averaged rate represents the entered test interval.
What if no water is caught?
The measured rates are zero. Uniformity is unavailable because the mean catch is zero.
Why are some cups labeled as tied at the cutoff?
They caught the same depth as the final cup included in the low quarter. Switching which equal value contributes does not change the mean.
Similar Calculators
Sprinkler & Drip Irrigation Zone Planner
Calculate sprinkler and drip zone flow, watering runtime and cycle-and-soak schedules. Visualize delivery, capacity limits and water shortfalls before your window closes.
Sprinkler Installation Cost & Route Calculator
Compare installed sprinkler bids from measured route lengths, shared trenches, individual pipes and surface repairs. Track missing scope and budget fit.
Polygon Area Calculator
Calculate polygon area from ordered coordinates, subtract cutouts, and inspect perimeter, centroid and point location on a consistently scaled plan.
Boom Sprayer Calibration Calculator & Water Output
Compare two recorded boom sprayer water tests. Convert nozzle catches and measured travel time to US gallons per acre and find output outliers.