Serial Dilution Calculator
Plan a dilution series around the concentration and volume you want to keep. Work backward from retained volumes, or check an entered transfer schedule, with a concentration plot and a material balance for every stage.
Plan the series. Keep the volume you need.
Explore concentrations, transfers and the material left at every stage.
Each mode and basis keeps its own plan. Switching restores that plan; it does not convert mass concentration to molar concentration.
Try an example
Stock is separate from the numbered stages.
1–24 prepared stages.
A factor of 10 makes each concentration one tenth of the previous one. A factor of 1 adds no diluent.
The amount left after any onward transfer. No final volume is discarded.
Compare available stock
Not used unless enabled. You can edit it now; volume-unit changes must still preserve this entry.
3 stages. Required stock ≈ 1.11 mL. Final concentration ≈ 1 µg/mL.
Final concentration
≈ 1 µg/mL
Cumulative dilution factor ≈ 1,000.
Stock required
≈ 1.11 mL
External stock drawn once, not the sum of inter-stage transfers.
Total diluent
≈ 28.89 mL
Total retained volume
≈ 30 mL
3 stages; no terminal discard.
What is being planned
Every stage is fully mixed. Diluent adds no solute, volumes add, and no material is lost. The last stage keeps its full prepared volume.
Values marked ≈ are rounded for reading. Exact fractions and scientific values remain available in the ledger and CSV. This is a quantitative plan, not a validated laboratory procedure.
Concentration through the series
Log₁₀ of concentration / stock
Equal vertical steps represent equal concentration ratios. Zero is the stock concentration; −1 is one tenth of stock and −2 is one hundredth. Outlined circles mark the inspected stage. Marks that overlap do not imply equal concentrations.
Stage 1: what enters and what remains
Source: stock at ≈ 1,000 µg/mL. This stage: ≈ 100 µg/mL. Step dilution factor ≈ 10.
Liquid volume
Each full bar represents ≈ 11.1 mL.
- Incoming
- ≈ 1.11 mL
- Diluent
- ≈ 9.99 mL
- Onward
- ≈ 1.1 mL
- Retained
- ≈ 10 mL
Solute amount
Each full bar represents ≈ 1,110 µg.
- Incoming
- ≈ 1,110 µg
- Diluent
- 0 µg
- Onward
- ≈ 110 µg
- Retained
- ≈ 1,000 µg
The panels have separate physical units and scales. Solid incoming/retained bars and dashed diluent/onward bars identify the partitions. These are material balances, not vessel dimensions.
Dilution stages and material balance
All quantities come from the same calculated series.
| Stage | Concentration | Step factor | Incoming | Diluent | Prepared | Onward | Retained | Retained solute |
|---|---|---|---|---|---|---|---|---|
| 1 (inspected) | ≈ 100 µg/mL | ≈ 10 | ≈ 1.11 mL | ≈ 9.99 mL | ≈ 11.1 mL | ≈ 1.1 mL | ≈ 10 mL | ≈ 1,000 µg |
| 2 | ≈ 10 µg/mL | ≈ 10 | ≈ 1.1 mL | ≈ 9.9 mL | ≈ 11 mL | ≈ 1 mL | ≈ 10 mL | ≈ 100 µg |
| 3 | ≈ 1 µg/mL | ≈ 10 | ≈ 1 mL | ≈ 9 mL | ≈ 10 mL | 0 mL | ≈ 10 mL | ≈ 10 µg |
Whole-series volume
Stock ≈ 1.11 mL plus diluent ≈ 28.89 mL equals retained ≈ 30 mL.
Exact balance residual: 0 mL.
Whole-series solute
Stock solute ≈ 1,110 µg equals retained solute ≈ 1,110 µg.
Exact balance residual: 0 µg.
Full quantities for the inspected stage
Exact fractions use the displayed unit. Scientific values may be rounded; their exponent remains meaningful even when a normal decimal display is too small.
| Quantity | Exact value | Scientific value |
|---|---|---|
| Source concentration | 1000 µg/mL | 1e+3 µg/mL |
| Stage concentration | 100 µg/mL | 1e+2 µg/mL |
| Step dilution factor | 10 | 1e+1 |
| Cumulative dilution factor | 10 | 1e+1 |
| Fraction of stock concentration | 1/10 | 1e-1 |
| Incoming volume | 111/100 mL | 1.11e+0 mL |
| Diluent volume | 999/100 mL | 9.99e+0 mL |
| Prepared volume | 111/10 mL | 1.11e+1 mL |
| Onward transfer | 11/10 mL | 1.1e+0 mL |
| Retained volume | 10 mL | 1e+1 mL |
| Incoming solute | 1110 µg | 1.11e+3 µg |
| Prepared solute | 1110 µg | 1.11e+3 µg |
| Onward solute | 110 µg | 1.1e+2 µg |
| Retained solute | 1000 µg | 1e+3 µg |
| Volume preparation residual | 0 mL | 0 mL |
| Volume partition residual | 0 mL | 0 mL |
| Solute preparation residual | 0 µg | 0 µg |
| Solute partition residual | 0 µg | 0 µg |
View CSV text
Method, assumptions and sources
Fixed-factor and target plans work backward from the final retained volume. Transfer-audit plans follow the entered volumes forward. There is no final discard and no automatic rounding to an instrument’s resolution.
Perfect mixing, zero-solute diluent and additive volumes are assumed. No reaction, evaporation, adsorption or other loss is included. The planner does not choose a clinical dose, validate a laboratory protocol or establish equipment suitability.
Mass and amount-of-substance concentrations are separate. A compatible unit change preserves quantities only within this plan, including the disabled available-stock entry. It does not infer a molecular mass.
- Ideal homogeneous mixing, compatible solute and diluent, additive volumes, and no loss, reaction, adsorption or evaporation.
- Diluent contains none of the tracked solute. The final outgoing transfer and terminal discard are zero.
- Stock is separate from the prepared stages. Only the first incoming transfer is external stock use.
- Mass and amount-of-substance concentration families are separate; no molecular mass is inferred.
- Exact decimal/rational balances do not establish equipment resolution, chemical handling, assay suitability, clinical dosing or a physically meaningful continuum at arbitrarily small amounts.
Conservation in each preparation
C_previous × incoming = C_stage × prepared; prepared = incoming + diluent.Required retained-volume planning
From the final stage backward: prepared_i = retained_i + transfer_(i+1); transfer_i = prepared_i × C_i / C_(i−1). Final transfer_(N+1) = 0.Entered-transfer evaluation
C_i = C_(i−1) × transfer_i / (transfer_i + diluent_i); retained_i = prepared_i − transfer_(i+1). Validate withdrawal before adding downstream diluent.Whole-series balance
stock draw + total diluent = total retained volume; stock concentration × stock draw = sum of retained solute.Entered values accept up to 16 significant digits and 24 effective decimal places. Stock and entered target concentrations span 1e-24 to 1e12 g/L or mol/L. Positive entered volumes span 1e-24 to 1e6 L; diluent and intermediate retained volumes may also be zero. Available stock spans zero to 1e9 L, and factors span 1 to 1e24. These are calculation limits, not equipment specifications.
Derived exact quantities can be much smaller than the entered-value range; scientific notation preserves their positive value. Very large rational calculations can return an explicit arithmetic-limit error instead of a result.
- OpenStax Chemistry 2e: molarity and dilution explains conserved solute amount.
- NIST: SI prefixes supplies the decimal prefix factors.
- Sapidyne TN203 distinguishes prepared, transferred and retained volumes. Its illustrated final discard differs from this planner’s no-discard boundary.
How to use this calculator
- Choose Common factor, Target concentrations or Entered transfers, then choose mass concentration or molar concentration. Each mode and concentration basis keeps a separate plan; switching restores that plan rather than converting mass to moles.
- Select compatible concentration and volume units and enter stock concentration. In Common factor, enter 1–24 stages, a factor of at least 1 and the volume to retain in each stage. Stock itself is not counted as a stage.
- For Target concentrations, enter a nonincreasing positive concentration and retained volume for each stage. For Entered transfers, enter incoming transfer and added diluent; the next transfer is withdrawn from the preceding stage. The final prepared volume is retained without a discard.
- Inspect the concentration plot and select a stage to compare incoming, prepared, outgoing and retained quantities. The volume and solute diagrams have separate scales; the data table preserves values that are too small to distinguish in a plot.
- Optionally compare available stock with required stock. A shortage is a comparison, not an invalid dilution series. Correct an invalid enabled comparison before exporting the complete CSV, or disable it. Download the series or select the identical CSV text.
The Formula
The mathematical logic powering this calculation is:
Stock is stage 0; the 1–24 prepared stages follow it. Let Cᵢ be concentration, Tᵢ incoming transfer volume, Dᵢ diluent, Pᵢ prepared volume, and Rᵢ the volume retained after the next transfer. All concentrations within a plan use one compatible basis.
Conserved solute at each mixing step: Cᵢ₋₁Tᵢ = CᵢPᵢ, with Pᵢ = Tᵢ + Dᵢ. For a common factor F ≥ 1, Cᵢ = C₀/Fⁱ. Custom targets must be positive and nonincreasing.
Backward retained-volume planning: set Tₙ₊₁ = 0, then calculate Pᵢ = Rᵢ + Tᵢ₊₁, Tᵢ = PᵢCᵢ/Cᵢ₋₁, and Dᵢ = Pᵢ − Tᵢ from the last stage to the first. Intermediate Rᵢ may be zero; the last must be positive. There is no terminal discard.
Entered transfers: Pᵢ = Tᵢ + Dᵢ and Cᵢ = Cᵢ₋₁Tᵢ/Pᵢ. Retained volume is Rᵢ = Pᵢ − Tᵢ₊₁, with the last outgoing transfer zero. A downstream transfer cannot exceed the previous prepared volume.
Whole-series balances: T₁ + ΣDᵢ = ΣRᵢ and C₀T₁ = ΣCᵢRᵢ. Only T₁ is external stock use; later transfers move material already in the series. Cumulative dilution factor = C₀/Cᵢ.
The model uses exact rational arithmetic for entered decimal values and balance quantities, then rounds scientific displays. Log plot coordinates describe log₁₀(Cᵢ/C₀). Tiny positive values remain positive in the data even if a linear chart cannot resolve their coordinate.
Assumptions: homogeneous mixing, zero-solute diluent, additive volumes, and no reaction, evaporation, adsorption or other loss. This is a quantitative planning model, not an assay, dosing or equipment protocol.Worked Example
If you input:
- Planning mode: Common factor
- Concentration basis: Mass concentration
- Concentration unit: µg/mL
- Volume unit: mL
- Stock concentration: 1000
- Number of stages: 3
- Dilution factor per stage: 10
- Retained volume per stage: 10
- Compare available stock: No
Result:
Starting from 1,000 µg/mL, three tenfold stages finish at 100, 10 and 1 µg/mL. To retain 10 mL in every stage, prepare 11.1, 11 and 10 mL, using incoming transfers of 1.11, 1.1 and 1 mL and diluent volumes of 9.99, 9.9 and 9 mL. The series uses 1.11 mL of stock plus 28.89 mL of diluent and retains 30 mL in total. Its 1,110 µg of retained solute equals the solute drawn from stock. The final concentration is 1,000 times lower than stock, with no final discard.
Frequently Asked Questions
What is a serial dilution factor?
The factor for one stage is source concentration divided by its resulting concentration, equivalently prepared volume divided by incoming transfer when diluent contains no solute. A factor of 10 gives one tenth of the source concentration. Three successive factors of 10 give a cumulative factor of 1,000. Factor 1 and equal target concentrations are allowed and mean no dilution in that step.
Why can prepared volume be larger than retained volume?
Prepared volume includes both the volume you will keep and the volume needed for the next transfer. If the last stage must retain 10 mL at a tenfold dilution, it needs 1 mL from the preceding stage. That preceding stage must therefore prepare 11 mL to keep its own 10 mL. The planner works backward through all stages and makes no final discard.
How does checking entered transfers differ from planning retained volumes?
Entered transfers calculates concentrations and remaining volumes from your transfer and diluent entries. Three stages of 1 mL transfer plus 9 mL diluent prepare 10 mL each, but retain 9, 9 and 10 mL because the first two supply the next transfer. Common factor and Target concentrations instead calculate preparations that satisfy your requested retained volumes. The modes keep separate drafts.
Can this convert mass concentration to molar concentration?
No molecular mass is assumed. Mass concentration and molar concentration have separate plans. Compatible unit changes within one basis preserve the quantities in that selected plan. For example, 1 mg/mL equals 1 g/L, while 1 µg/mL equals 1 mg/L. Solute amount labels follow the concentration numerator: a µg/mL plan reports solute in µg, regardless of its volume display unit.
What happens if I do not have enough stock?
The optional comparison shows available stock minus required stock and identifies a surplus, exact match or shortage. A shortage does not alter the mathematical series. An invalid enabled availability entry leaves valid series results visible but disables the complete export until the comparison is corrected or disabled. Internal transfers are not counted again as external stock use.
Why use a logarithmic concentration plot?
Equal logarithmic spacing represents equal concentration ratios, so repeated tenfold steps stay legible across many orders of magnitude. Linear spacing represents the concentration relative to stock directly. Very small positive quantities can overlap or fall below a chart coordinate's resolution; those states are identified, with scientific values retained in the table and export. Neither chart establishes practical measurement or dispensing precision.
Which assumptions and numerical limits apply?
The calculation assumes homogeneous mixing, zero-solute diluent, additive volumes and no loss or reaction. It does not establish chemical compatibility, assay validity, clinical doses or suitable equipment. There are 1–24 prepared stages. Authored numbers allow 16 significant digits and 24 effective decimal places. Entered concentrations span 1e−24 to 1e12 g/L or mol/L; positive entered volumes span 1e−24 to 1e6 L; stock availability spans 0 to 1e9 L; common factors span 1 to 1e24. These are computational bounds, not physical recommendations. Derived positive values may be much smaller and remain represented exactly with rounded scientific displays.
What information is included in the CSV?
The complete export includes selected inputs, units, stock, every stage, material balances, totals, any enabled valid stock comparison, plot metadata and assumptions. Exact rational values and separate scientific mantissa and exponent columns preserve quantities that ordinary spreadsheet numeric cells may round or underflow. The selectable text uses the same serialization as the download.
Similar Calculators
Pool Salt Calculator
Estimate pool salt mass from measured and target salinity, water volume and purity. Compare the amount to add with whole bags to buy and measurement scenarios.
Ratio Calculator
Simplify ratios, find equivalent ratios, and solve for a missing value in a proportion.
Recipe Scaling Calculator
Scale ingredient quantities from original servings to desired servings with fraction-friendly kitchen output.
Stoichiometry Calculator
Balance a reaction, find limiting reactants and calculate theoretical yield or target-product requirements. Inspect formula masses, leftovers and actual yield separately.
DNA Primer Melting Temperature Calculator
Compare DNA melting temperatures with nearest-neighbor calculations, explicit strand and salt concentrations, sensitivity plots, sequence ledgers and CSV export.
