Ice & Water Shield Eave Coverage Calculator

Translate your written horizontal eave coverage into sloped roof width. Compare two membrane widths and side laps across two measured eaves, see whether the first course reaches the target, and total the lineal material before any end laps or waste.

Measured eave membrane takeoff

Compare eave membrane reach

Edit eave measurements and membrane plans

Copy the target from your written detail. Measure both wall-line distances horizontally from the eave edge.

Eave 1
Eave 2
Plan A
Plan B

Plan A needs less lineal membrane.

Plan A

56 ft

Lineal membrane before end laps and waste

Usable course width
45 in
Total courses across both eaves
2
Side-lap line length
0 ft

Plan B

88 ft

Lineal membrane before end laps and waste

Usable course width
44.999 in
Total courses across both eaves
3
Side-lap line length
32 ft

Inspect an eave section

Membrane reach from the eave edge

Horizontal inches

  • Marked wall line
  • Required reach

Each colored bar shows the full reach of its minimum courses. The solid mark on each bar shows the end of its first course.

Eave 1 · 32 ft run

Horizontal target from edge
36 in
Minimum sloped width to 0.001 in
45 in

Plan A

First course meets the exact target

First course horizontal reach
36 in
Minimum full-width courses
1
Net lineal membrane
32 ft

Plan B

First course falls short

Final course extends past the target

First course horizontal reach
35.9992 in
Minimum full-width courses
2
Net lineal membrane
64 ft
Review the exact course ledger
Eave distances and full-width course quantities
Eave and planHorizontal targetSloped width to 0.001 inWidth providedCoursesLineal membraneSide-lap lines
1 · Plan A36 in45 in45 in132 ft0 ft
1 · Plan B36 in45 in83.998 in264 ft32 ft
2 · Plan A40 in43.334 in45 in124 ft0 ft
2 · Plan B40 in43.334 in44.999 in124 ft0 ft

How to use this calculator

  1. Copy the specified horizontal reach beyond the wall datum in the written eave detail.
  2. Enter each straight eave length, the horizontal distance from the eave edge to that datum and the roof rise in 12 in.
  3. Compare two documented membrane widths and side overlaps. Check the course count and the horizontal section for each eave, then export the exact takeoff.

The Formula

The mathematical logic powering this calculation is:

Use a straight eave and one constant roof pitch per measured section. Mark the same wall datum specified in the written detail. Enter the horizontal distance from the eave edge to that datum, which can include both the roof overhang and the wall thickness. Add the entered horizontal target beyond that wall line. This sum is the horizontal distance from the eave edge to the target.

Convert the horizontal distance H to the sloped distance by multiplying by the square root of 1 + (rise per 12 ÷ 12)². The minimum sloped width in the ledger is rounded upward to the next 0.001 in when needed. The cross section approximates the slope for drawing. At every coverage boundary the calculator compares the exact squared distances. An edge on the target counts as covered.

The first course supplies its entire usable width W along the roof slope. Each additional course advances by W minus the entered side lap. When the first course falls short, add the fewest courses needed for the total width to reach the sloped distance. A zero required distance needs zero courses. With a positive span, one exact course has no side lap and two or more courses contribute one side lap per added course.

Multiply the course count by the measured eave run, parallel to the eave, for net lineal membrane. The sum covers both eaves before end laps, transitions, waste or roll packing. Multiplying each added course by the eave run gives the length of the side-lap lines. Those are lengths along the eave, separate from the side-lap width across the slope.

Pitch uses 0–36 in of rise per 12 in. Horizontal distances and side laps use 0–240 in. Widths use 1–240 in, and runs use 0.001–2,000 ft. Values accept up to three decimals. Enter the written target, usable widths and overlap for your actual roof detail. The illustrative inputs describe geometry and quantities. A roof with valleys, changes of pitch, hips or other transitions requires their own measured detail. Stock rolls and product compatibility are separate decisions.

Worked Example

If you input:

  • Written horizontal reach: 24 in beyond marked wall line
  • First eave: 32 ft long, 12 in to wall, 9:12 pitch
  • Second eave: 24 ft long, 16 in to wall, 5:12 pitch
  • Membrane widths: 45 in and 44.999 in, with 6 in side laps

Result:

Eave 1 needs 45 in along the slope. Plan A meets it in exactly one course and plan B needs two. Both plans need one course on eave 2. The lineal totals before end laps are 56 ft for A and 88 ft for B.

Frequently Asked Questions

What is the wall datum?

Use the actual reference in your written detail. The entry is the distance measured horizontally from the eave edge to that wall line.

Can I enter sloped roof distance as the target?

Enter horizontal distance beyond the wall line. The worksheet uses pitch to calculate the sloped width.

Why is the extra course worth less than a full roll width?

Part of the extra course overlaps the prior one. The new width is the usable width minus that side lap.

Does this give the number of rolls to order?

The worksheet totals lineal membrane for each entered width and shows side-lap length. End laps, roll packaging and other cuts affect what goes on the order.

Can I use unequal roof pitches?

Yes. Enter the measured rise per 12 in for each of the two straight eave sections.

Similar Calculators