Open Channel Flow & Freeboard Planner

Review the same target discharge against two measured channel sections. Find the modeled water level, critical depth and capacity below your entered freeboard, then trace the available range on paired cross-sections and stage–discharge curves.

Manning flow · SI

Compare channel stage, capacity and freeboard

Channel A reaches the target with the entered margin.

Steady uniform flow through a constant section. Use measured geometry and project data for roughness and margin.

Channel A · Rectangle

Meets requested freeboard

Normal depth

0.47769 m

Capacity at usable depth
1.6025 m³/s
Capacity at bank
2.32867 m³/s
Remaining freeboard
0.17231 m
Requested freeboard
0.15 m

Channel B · Trapezoid

Uses requested freeboard

Normal depth

0.54812 m

Capacity at usable depth
1.28024 m³/s
Capacity at bank
2.01922 m³/s
Remaining freeboard
0.10188 m
Requested freeboard
0.15 m

Channel A: Meets requested freeboard. Channel B: Uses requested freeboard. Channel A reaches the target with the entered margin.

Edit Channel A
Edit Channel B

Water levels at the target flow

Heights share a vertical scale and widths share a horizontal scale. The shaded water stops at the modeled normal depth when it falls inside the section.

  • Bank
  • Usable depth
  • Normal depth
  • Critical depth

Channel A · Rectangle

Channel A cross-section and depth markers
Bank depth
0.65 m
Usable depth
0.5 m
Normal depth
0.47769 m
Critical depth
0.38566 m

Channel B · Trapezoid

Channel B cross-section and depth markers
Bank depth
0.65 m
Usable depth
0.5 m
Normal depth
0.54812 m
Critical depth
0.47697 m

Stage–discharge curves

Each curve ends at its entered bank. Circles mark a usable limit, squares mark a bank, and diamonds mark a normal stage. The dashed horizontal line is the target flow.

  • Channel A
  • Channel B
  • Target flow
Discharge2.32867 m³/s top scale
Modeled discharge by channel depth with target and depth probe
0 mDepth0.65 m
0.325 m
Channel A discharge
0.84899 m³/s
Channel B discharge
0.6169 m³/s

Hydraulic results and export

Velocity, area, top width, hydraulic radius and regime describe the modeled normal stage. Usable capacity minus target measures flow headroom under the entered freeboard criterion.

Comparison of modeled hydraulic results by channel
MeasureChannel AChannel B
Usable capacity minus target0.1025 m³/s-0.21976 m³/s
Froude number0.725420.79368
Flow regimeSubcriticalSubcritical
Mean velocity1.57007 m/s1.64749 m/s
Wetted area0.95537 m²0.91047 m²
Water surface width2 m2.07218 m
Hydraulic radius0.32327 m0.34747 m
Margin above requested freeboard0.02231 m-0.04812 m
Download open channel comparison CSV
Show selectable CSV text

How to use this calculator

  1. Enter the shared target discharge in cubic metres per second.
  2. Choose a rectangular or symmetric trapezoidal section for each channel. Enter bottom width, bank depth and the side slope for a trapezoid.
  3. Enter bed grade, Manning roughness and requested freeboard for each reach.
  4. Compare normal and critical depths, remaining freeboard and both modeled capacity limits.
  5. Move the depth probe to compare both stage–discharge curves. Download the summary and stage samples as CSV.

The Formula

The mathematical logic powering this calculation is:

For a symmetric trapezoid with bottom width b, depth y and side slope z horizontal per one vertical, wetted area A = y(b + zy), wetted perimeter P = b + 2y√(1 + z²), and water surface width T = b + 2zy. A rectangle has z = 0. The hydraulic radius R = A/P and hydraulic depth D = A/T. The dry model point has zero water area, flow and wetted perimeter.

The SI Manning equation gives Q = A R^(2/3) √S / n. This assumes steady uniform flow through a prismatic section, with the measured bed slope used as the energy slope S. Enter percentage grade, so 1% becomes S = 0.01. The usable depth is surveyed bank depth minus requested freeboard. The planner calculates capacity at that depth and at bank depth independently, then finds the normal depth whose discharge matches the target when the solution lies within the modeled section. Remaining freeboard is bank depth minus normal depth. Exact equality at the usable limit meets the entered freeboard. Equality at the bank has zero remaining freeboard. A target above the computed bank capacity has no modeled normal depth.

When a positive normal depth is available, mean velocity is Q/A and the Froude number is V/√(gA/T), using g = 9.80665 m/s². Critical stage is where Q²T/(gA³) equals 1. It is solved independently and only reported within the surveyed bank. At the normal stage, Fr below, equal to or above 1 shows subcritical, critical or supercritical modeled flow. At zero target the normal result is dry. At zero bed slope the model finds no positive uniform flow capacity. A critical stage for the same target may still exist in the section.

Inputs are in SI, with up to six decimals. Target flow is 0–5,000 m³/s, bottom width 0.05–100 m, side slope 0–10 H:V, bank depth 0.01–20 m, freeboard 0–bank depth, slope 0–25%, and Manning n 0.005–0.8. Enter the applicable roughness, bank depth and freeboard criterion from the project data. The modeled range ends at the entered bank. Flow controls, backwater, transitions, bypass flow, erosion, sediment, structural design, safety and permitting are outside this uniform-flow comparison.

Worked Example

If you input:

  • Target flow: 1.5 m³/s
  • Channel A: 2 m rectangular bottom width.
  • Channel B: 1.25 m trapezoidal bottom width and 0.75 H:1 V side slopes.
  • Both channels: 1% bed slope, Manning n of 0.03, 0.65 m to bank and 0.15 m requested freeboard.

Result:

At a usable depth of 0.5 m, A carries 1.6025 m³/s and B carries 1.28024 m³/s. At the 1.5 m³/s target, the modeled normal depths are 0.47769 m and 0.54812 m. A retains 0.17231 m of freeboard, enough for the entered criterion. B remains below bank with 0.10188 m of freeboard.

Frequently Asked Questions

What is freeboard in this comparison?

It is the vertical distance from the modeled water surface to the entered bank. Requested freeboard is your input. Remaining freeboard is calculated at the normal depth when that stage falls inside the section.

Why can a channel reach the target but use the requested freeboard?

The target can exceed the discharge at the usable depth and still fit within the entered bank. In that case the normal depth lies in the part of the section reserved by your freeboard input.

What does above modeled bank mean?

The target exceeds the uniform-flow capacity computed at the entered bank depth. The worksheet ends there because it has no geometry for water above the bank or outside the channel.

How do normal depth and critical depth differ?

Normal depth is the depth for steady uniform flow with the entered roughness and bed slope. Critical depth depends on section geometry and target flow. It is the stage where the Froude number reaches one.

What side slope should I enter in a trapezoid?

Enter horizontal widening per unit of vertical rise on each side. For example, 1.5 H:1 V widens the whole section by 3 m for each metre of rise.

How can I choose a Manning roughness value?

Use a documented value for your actual lining, vegetation and reach conditions. A change in roughness changes both the modeled discharge at a given stage and the normal stage for the same flow.

Similar Calculators