Numerical Aperture Cone Clearance Calculator

Use the numerical aperture and refractive index on one optical side to model a point-apex cone. Compare two perpendicular circular openings by their clear diameter and measured maximum lateral offset. See when each opening passes the complete cone, touches it, or clips it.

Point-apex optical geometry

Compare aperture clearance across an optical cone

Edit numerical aperture, distance and stop dimensions

Measure each offset perpendicular to the cone axis and use the actual clear opening diameter.

Stop A
Stop B

Only Stop A fits the full distance range.

Half-angle 36.86989765° · Plane range 4 mm to 8 mm

Stop A

Whole distance range fits

Farthest plane without clipping

8 mm

Near endpoint
Clears the opening
Far endpoint
Touches the aperture edge
Available radius after offset
6 mm

Stop B

Only part of the range fits

Farthest plane without clipping

6.66666667 mm

Near endpoint
Clears the opening
Far endpoint
Clips the modeled cone
Available radius after offset
5 mm

Inspect the cone at an opening plane

Section through the offset

Apex · 0 mmFar end · 8 mm
  • Cone
  • Material around opening

Axial and radial scales differ.

8 mm from apex · Stop A

Touches the aperture edge

Cone radius 6 mm

Opening radius 7 mm · Offset 1 mm

Signed radial clearance 0 mm

Review the exact cone clearance ledger
Exact aperture and squared cone dimensions
StopUsable radius (mm)Near cone radius² (mm²)Far cone radius² (mm²)Maximum distance² (mm²)Near endpointFar endpoint
A693664Clears the openingTouches the aperture edge
B5936400/9Clears the openingClips the modeled cone

How to use this calculator

  1. Enter the refractive index on the modeled optical side and its numerical aperture.
  2. Enter the nearest and farthest opening plane distances from the point apex.
  3. Enter each option’s measured clear opening diameter and maximum lateral center offset.
  4. Compare the maximum geometric distance and endpoint results. Select a stop and distance to see the section through the offset.
  5. Review the squared-distance ledger or download the exact CSV.

The Formula

The mathematical logic powering this calculation is:

For a rotationally symmetric cone from a point apex, use the refractive index n on the modeled side and NA = n sin(θ), where θ is the half-angle. At a perpendicular plane d millimeters from the apex, the cone radius is d tan(θ). The worksheet uses tan²(θ) = NA²/(n² − NA²) directly.

For a thin circular opening of clear diameter D and maximum lateral center offset e, the worst-case cone fits if its radius is at most D/2 − e. First check that this available radius is nonnegative, then compare d² tan²(θ) ≤ (D/2 − e)² exactly. Equality is an edge contact and counts as contained in the geometry. Since cone radius grows with nonnegative distance, checking the near and far endpoints tells whether all, some or none of the closed distance range fits.

When NA is positive and the available radius is nonnegative, the maximum allowable distance is (D/2 − e)/tan(θ). For NA = 0 the point-apex model is a single ray and the distance limit is absent if the axis passes through or touches the opening. A negative available radius leaves no allowable distance, including at the apex. The exact export records squared distances and radii to retain the solved quantities even when their square roots are irrational. Angle, diagram geometry and displayed decimal lengths are approximate.

Inputs allow n from 1 to 4, 0 ≤ NA < n, nonnegative ordered distances and offsets to 1,000 mm, and clear diameters of 0.0001–1,000 mm. Use up to four decimal places. This geometric comparison assumes a thin opening perpendicular to the common axis and a uniform medium, with the offset measured perpendicular to the axis. It excludes diffraction, finite beam width at the apex, ray bending between media, tilt, alignment changes over travel, mount thickness and optical power.

Worked Example

If you input:

  • Cone in air: n = 1, NA = 0.6
  • Distance: 4–8 mm
  • Stop A: 14 mm clear diameter and 1 mm lateral offset
  • Stop B: 16 mm clear diameter and 3 mm lateral offset

Result:

The half-angle is approximately 36.8699° and the cone radius at 8 mm is 6 mm. Stop A just touches at that distance and fits throughout. The larger Stop B clips the cone beyond 20/3 mm because its greater offset leaves less usable radius.

Frequently Asked Questions

Which angle does the numerical aperture determine?

It determines the half-angle from the axis to the cone edge in the entered medium. The angle across the full cone is twice that value.

Why can a larger opening clip first?

The offset subtracts from the opening radius on the narrow side. A larger but less centered opening can leave less usable radius than a smaller centered one.

Why do you square lengths in the comparison?

Once the usable radius is known to be nonnegative, squared lengths give the same decision and keep decimal-input boundaries exact even when an angle or radius is irrational.

Do you count tangent contact as fitting?

Yes, this is a closed geometric comparison. The endpoint text distinguishes contact from positive clearance.

Does zero NA represent a real collimated beam diameter?

In this point-apex model zero NA gives a single axis ray. A physical beam with nonzero initial diameter needs a different envelope.

Does clipping show how much optical power is lost?

It describes whether the cone edge extends beyond the clear opening. Power also depends on the distribution of intensity and the optical system.

Similar Calculators