Magnet Pull Force & Gap Audit

Enter repeated axial pull readings at measured gaps from two documented setups. Compare their lowest observed readings, find every modeled force-floor crossing and see whether an entire target gap band meets your bench-test threshold.

Recorded axial bench tests

Compare magnet pull force across measured gaps

Edit the target and measured pull tests

One row per gap in mm, followed by two to six peak pulls in N. Separate values with commas.

One row per gap in mm, followed by two to six peak pulls in N. Separate values with commas.

Only Setup A meets the force floor over the entered gap band.

Target gap 0.5 to 1.5 mm · Floor 10 N

Setup A

Entered band meets the modeled floor

Lowest modeled pull in target

10 N

1.5 mm · between measured stations

Exactly at the entered floor

Setup B

Entered band falls below the modeled floor

Lowest modeled pull in target

9 N

1 mm · measured station

1 N below floor

The curve compares entered axial bench measurements. Use documented ratings and application tests for any load decision.

Inspect the measured pull-force curve

Axial pull force · 0–20 N

10 N entered floor

0 mm3 mm
  • Station minima
  • Observed spread
  • Target gap
  • Force floor
  • Target’s lowest point
  • Qualifying gaps

0 mm · Setup A

Minimum 16 N · Mean 17 N

Maximum 18 N · 3 readings

Modeled intervals meeting the floor

  • 0 to 1.5 mm
Review the exact pull-force ledger
Exact measured gaps and pull-force statistics
SetupGap mmRaw pulls NMinimum NMean NMaximum N
A016 · 17 · 18161718
A112 · 13 · 14121314
A28 · 9 · 108910
A36 · 7 · 8678
B018 · 19 · 20181920
B19 · 10 · 1191011
B213 · 14 · 15131415
B37 · 8 · 9789

How to use this calculator

  1. Enter the comparison force floor and the target gap range. Use the same gap value twice to compare at a point.
  2. Paste a gap and two to six recorded axial peak pulls per row for each setup. Use mm and N.
  3. Compare the worst value in the entered range, its basis and the force margin against the floor.
  4. Inspect the test stations and all qualifying intervals, then download the exact test ledger.

The Formula

The mathematical logic powering this calculation is:

At each measured gap, take the smallest, arithmetic mean and largest entered peak axial pull. The model connects only the station minima by straight lines for comparison. Shaded spread connects the corresponding recorded minima and maxima visually. Repeat results describe the entered sample and are not a confidence bound. A modeled curve between measured gaps is an estimate.
Within each segment, an endpoint at or above the entered force floor qualifies. When endpoints differ in qualification, the crossing gap is left gap + (floor − left minimum) × (right gap − left gap) ÷ (right minimum − left minimum). Keep the qualifying side of each segment, include equality and merge adjacent eligible pieces. A single exact point or several disjoint intervals can qualify. Observed minima need not decrease monotonically.
If the two target endpoints lie inside a setup’s measured span, the minimum within the target is the smallest modeled value among its endpoints and all enclosed measured stations. Equal minima report the earliest gap. If any part of the target lies outside the measurements, the target comparison is unavailable for that setup. The worksheet never extends the curve beyond the entered stations.
Use this analysis for recorded axial bench measurements on documented setups. Materials, alignment, fixture, temperature and test geometry affect the readings. The worksheet does not infer a magnet specification, working load, shear resistance or safe attachment. Enter 2–16 ordered gaps with 2–6 nonnegative pulls per gap. Gap bounds are 0–1,000 mm and force through 10,000,000 N. Both support three input decimals. Decisions and CSV use exact fractions.

Worked Example

If you input:

  • Target: 0.5–1.5 mm, with a 10 N floor
  • Setup A observed minima: 16, 12, 8 and 6 N at gaps of 0, 1, 2 and 3 mm
  • Setup B observed minima: 18, 9, 13 and 7 N at the same gaps

Result:

Setup A’s lowest modeled pull in the band is 10 N at 1.5 mm. Setup B’s endpoints are above 10 N, but the 9 N interior station at 1 mm splits its qualifying interval and makes the target range fall short.

Frequently Asked Questions

Why compare the lowest observation instead of the mean?

The smallest recorded peak pull is a useful conservative descriptive value for that sample. The mean and maximum remain visible. More or different repeats can change the minimum, so it is not a guarantee or statistical lower limit.

What if my target gap is partly outside the measurements?

The available curve and its qualifying intervals stay visible. The target band comparison remains undetermined until the full band is covered by measurements.

Why can a setup have several qualifying gap ranges?

An interior low reading can break a range into separate pieces. The worksheet uses the entered data as given and does not force the minima to decline.

Does a qualifying interval rate the magnet for a load?

No. It meets the entered numerical floor on a curve drawn from a specific axial bench record. A load or attachment depends on its own rated specifications and application testing.