Magnet Pull Force & Gap Audit
Enter repeated axial pull readings at measured gaps from two documented setups. Compare their lowest observed readings, find every modeled force-floor crossing and see whether an entire target gap band meets your bench-test threshold.
Compare magnet pull force across measured gaps
Use repeat measurements from two setups to check a gap band against an entered force floor.
Edit the target and measured pull tests
One row per gap in mm, followed by two to six peak pulls in N. Separate values with commas.
One row per gap in mm, followed by two to six peak pulls in N. Separate values with commas.
Only Setup A meets the force floor over the entered gap band.
Target gap 0.5 to 1.5 mm · Floor 10 N
Setup A
Entered band meets the modeled floorLowest modeled pull in target
10 N
1.5 mm · between measured stations
Exactly at the entered floor
Setup B
Entered band falls below the modeled floorLowest modeled pull in target
9 N
1 mm · measured station
1 N below floor
The curve compares entered axial bench measurements. Use documented ratings and application tests for any load decision.
Inspect the measured pull-force curve
Axial pull force · 0–20 N
10 N entered floor
- Station minima
- Observed spread
- Target gap
- Force floor
- Target’s lowest point
- Qualifying gaps
0 mm · Setup A
Minimum 16 N · Mean 17 N
Maximum 18 N · 3 readings
Modeled intervals meeting the floor
- 0 to 1.5 mm
Review the exact pull-force ledger
| Setup | Gap mm | Raw pulls N | Minimum N | Mean N | Maximum N |
|---|---|---|---|---|---|
| A | 0 | 16 · 17 · 18 | 16 | 17 | 18 |
| A | 1 | 12 · 13 · 14 | 12 | 13 | 14 |
| A | 2 | 8 · 9 · 10 | 8 | 9 | 10 |
| A | 3 | 6 · 7 · 8 | 6 | 7 | 8 |
| B | 0 | 18 · 19 · 20 | 18 | 19 | 20 |
| B | 1 | 9 · 10 · 11 | 9 | 10 | 11 |
| B | 2 | 13 · 14 · 15 | 13 | 14 | 15 |
| B | 3 | 7 · 8 · 9 | 7 | 8 | 9 |
How to use this calculator
- Enter the comparison force floor and the target gap range. Use the same gap value twice to compare at a point.
- Paste a gap and two to six recorded axial peak pulls per row for each setup. Use mm and N.
- Compare the worst value in the entered range, its basis and the force margin against the floor.
- Inspect the test stations and all qualifying intervals, then download the exact test ledger.
The Formula
The mathematical logic powering this calculation is:
At each measured gap, take the smallest, arithmetic mean and largest entered peak axial pull. The model connects only the station minima by straight lines for comparison. Shaded spread connects the corresponding recorded minima and maxima visually. Repeat results describe the entered sample and are not a confidence bound. A modeled curve between measured gaps is an estimate.
Within each segment, an endpoint at or above the entered force floor qualifies. When endpoints differ in qualification, the crossing gap is left gap + (floor − left minimum) × (right gap − left gap) ÷ (right minimum − left minimum). Keep the qualifying side of each segment, include equality and merge adjacent eligible pieces. A single exact point or several disjoint intervals can qualify. Observed minima need not decrease monotonically.
If the two target endpoints lie inside a setup’s measured span, the minimum within the target is the smallest modeled value among its endpoints and all enclosed measured stations. Equal minima report the earliest gap. If any part of the target lies outside the measurements, the target comparison is unavailable for that setup. The worksheet never extends the curve beyond the entered stations.
Use this analysis for recorded axial bench measurements on documented setups. Materials, alignment, fixture, temperature and test geometry affect the readings. The worksheet does not infer a magnet specification, working load, shear resistance or safe attachment. Enter 2–16 ordered gaps with 2–6 nonnegative pulls per gap. Gap bounds are 0–1,000 mm and force through 10,000,000 N. Both support three input decimals. Decisions and CSV use exact fractions.Worked Example
If you input:
- Target: 0.5–1.5 mm, with a 10 N floor
- Setup A observed minima: 16, 12, 8 and 6 N at gaps of 0, 1, 2 and 3 mm
- Setup B observed minima: 18, 9, 13 and 7 N at the same gaps
Result:
Setup A’s lowest modeled pull in the band is 10 N at 1.5 mm. Setup B’s endpoints are above 10 N, but the 9 N interior station at 1 mm splits its qualifying interval and makes the target range fall short.
Frequently Asked Questions
Why compare the lowest observation instead of the mean?
The smallest recorded peak pull is a useful conservative descriptive value for that sample. The mean and maximum remain visible. More or different repeats can change the minimum, so it is not a guarantee or statistical lower limit.
What if my target gap is partly outside the measurements?
The available curve and its qualifying intervals stay visible. The target band comparison remains undetermined until the full band is covered by measurements.
Why can a setup have several qualifying gap ranges?
An interior low reading can break a range into separate pieces. The worksheet uses the entered data as given and does not force the minima to decline.
Does a qualifying interval rate the magnet for a load?
No. It meets the entered numerical floor on a curve drawn from a specific axial bench record. A load or attachment depends on its own rated specifications and application testing.
Similar Calculators
Tensile Strength & Coupon Proof Stress Calculator
Compare engineering tensile strength and offset proof stress from two recorded coupon traces. Inspect the first pre-peak crossing and exact thresholds.
Hydraulic Cylinder Force & Cycle Calculator
Compare push and pull force for two cylinders. Account for opposing chamber pressure, separate flow caps and the entered load in each direction.
Gas Spring Force & Lid Torque Calculator
Compare gas spring torque in opening and closing, check measured eye-to-eye travel and solve outward force for static balance at an entered lid angle.