Machine Interruption Frequency and Confidence Calculator

Use separately recorded operating runs to compare recurring machine interruptions, including zero-incident runs. Inspect each run's observed rate, exact-distribution upper limit, and operating hours at the same incident count.

Repairable equipment

Check machine incident rates against a target

Compare observed rates and one-sided Poisson limits across separately recorded operating runs.

Runs and rate target

Enter hours, then incidents on each line. Use one to six rows with a comma or tab between values.

Enter 50% to 99.9%.

Use the maximum rate you want to check.

0 of 3 runs have an upper limit within the target.

Rate and exposure for the selected run

Upper limit per 1,000 hours

2.49644

Above target

Observed rate per 1,000 hours

0

0 incidents in 1,200 operating hours

Observed rates and upper limits by run
Machine incident rates against your targetRun 1 has observed rate 0 and upper limit 2.49644. Target 2 incidents per 1,000 operating hours.Incidents per 1,000 hRun 1Run 2Run 305.27096

Dots mark observed rates. End caps mark one-sided upper limits. The dashed line is your target.

Exposure at the same incident count

Total operating hours for the target
1,497.87
Additional operating hours
297.866

This benchmark holds the incident count fixed. Choose a test length and allowable count before collecting data.

Use comparable operating conditions with independent events and a stable occurrence rate within each run.

Export the incident rate audit

The CSV lists every run, its observed rate, numerical upper limit, and hours benchmark.

View CSV text

How to use this calculator

  1. Enter the operating hours and whole incident count for each run. Separate values with a comma or tab and put each run on its own line.
  2. Set the one-sided confidence and your maximum rate per 1,000 operating hours.
  3. Use the chart and run slider to compare the observed rates and upper limits with the target.
  4. Check the total or additional hours benchmark at the same count. Download the audit for exact observed rates and numerical limits.

The Formula

The mathematical logic powering this calculation is:

For a run with k incidents in T operating hours, the observed rate per 1,000 operating hours is 1,000k/T. If exposure is fixed and incidents follow a homogeneous Poisson process, the count has Poisson mean λT, where λ is the constant incident rate per operating hour.

With one-sided confidence C as a fraction, set α = 1 − C. Find the mean µ such that P(Poisson(µ) ≤ k) = α. The one-sided upper rate per 1,000 operating hours is 1,000µ/T. For k = 0, µ = −ln(α). For positive k, the calculator inverts the exact Poisson distribution numerically. Take the upper endpoint as a repeated-sampling confidence procedure for a fixed exposure. Runs are evaluated separately, with no joint confidence guarantee across all runs.

For a positive target L per 1,000 hours, total exposure at the same count is 1,000µ/L. Additional exposure is that benchmark minus current hours, with a floor of zero. If the observed count increases, recompute the benchmark. For a prospective fixed-time test, choose the exposure and maximum allowable count before observing the outcomes. Repeatedly checking during a run until the bound falls below the target changes the statistical design.

Each row uses the number of incidents and the matching operating hours, excluding time when equipment was out of operation. Use a consistent incident definition. Trend, wear, clustering or changes in operating conditions can make a constant-rate model unsuitable. The worksheet supports one to six run rows, hours from 0.000001 to 1 billion and counts from 0 to 1,000. Confidence is 50% to 99.9% with up to three decimal places. Target and hours accept up to six decimal places, with rates from 0.000001 to 1,000,000. Observed rate is computed exactly. The upper bound and exposure benchmarks use numerical solutions. A relative gap of 10⁻¹⁰ or less is labeled near the decision boundary.

Worked Example

If you input:

  • Run rows: 1,200 hours with 0 incidents, 2,400 hours with 2, and 900 hours with 1
  • One-sided confidence: 95%
  • Target: 2 incidents per 1,000 operating hours

Result:

The zero-incident run has an upper limit of about 2.49644 per 1,000 operating hours. At the same count, the upper limit reaches 2 after about 1,497.87 operating hours.

Frequently Asked Questions

Why does a zero-incident run have a positive upper limit?

A finite run can contain zero incidents even when the underlying rate is positive. Increasing the zero-event exposure lowers the upper limit in inverse proportion to operating hours.

Why does the chart use each run's actual powered hours?

The count and exposure must describe the same operating activity. Planned breaks, repair stops, and other time when the equipment is out of operation do not contribute to the denominator.

Can I add hours until a run passes?

The hours result is a planning benchmark at a fixed count. Before collecting results for a fixed-time test, specify the exposure and maximum acceptable count. Monitoring and stopping when the bound qualifies requires a different statistical design.

Can I compare two runs simply by their observed rates?

The observed rate gives a point estimate. A shorter run can have a larger upper limit even when its point estimate is lower. These separate upper limits help check a target for each run. A formal comparison of two rates requires a test or an interval for their difference or ratio.

Similar Calculators