LDL Cholesterol Calculator
Estimate LDL-C from total cholesterol, HDL-C and triglycerides with two published equations. Add the LDL-C printed on your lab report for comparison, or compare two complete panels using the same calculations. The chart and ledger show where each equation can be used and how comparable concentrations differ between panels.
LDL cholesterol comparison
See how two published equations compare with the value printed on a lipid panel.
Enter a lipid panel
Use readings from the same specimen for each panel. Enter a reported LDL-C only if it appears on that report.
Compare the estimates
Friedewald estimate for Panel A 120 mg/dL. Sampson (NIH) estimate for Panel A 123 mg/dL. Lab-reported LDL-C for Panel A 125 mg/dL. Non-HDL-C for Panel A 150 mg/dL
- Friedewald estimatePanel A120 mg/dL
- Sampson (NIH) estimatePanel A123 mg/dL
- Lab-reported LDL-CPanel A125 mg/dL
- Non-HDL-CDerived from total and HDL-C150 mg/dL
Lipid comparison ledger
A difference is available when both panels supply the same measure.
| Measure | Panel A |
|---|---|
| Friedewald estimate | 120 mg/dL |
| Sampson (NIH) estimate | 123 mg/dL |
| Lab-reported LDL-C | 125 mg/dL Copied from the lab report |
| Non-HDL-C | 150 mg/dL |
How to use this calculator
- Select the Concentration unit shown on your lab report. Enter Total cholesterol, HDL-C and Triglycerides for Panel A from the same specimen.
- If the report also gives a Lab-reported LDL-C, copy that reading into the optional field. It appears next to the two equation estimates.
- Review Compare the estimates and the Lipid comparison ledger. The ledger explains an unavailable estimate and shows non-HDL-C separately.
- Choose Compare with Panel B to add a second set of readings. B minus A compares the same measure wherever both panels supply it.
- Use Download lipid comparison CSV to keep the original readings, both units and comparable changes. Show selectable CSV displays the same export for copying.
The Formula
The mathematical logic powering this calculation is:
All equations below use concentrations in mg/dL. Non-HDL-C = total cholesterol − HDL-C. Friedewald LDL-C = non-HDL-C − triglycerides ÷ 5. This calculator provides the Friedewald estimate only when triglycerides are below 400 mg/dL.
Sampson LDL-C = (total cholesterol ÷ 0.948) − (HDL-C ÷ 0.971) − [triglycerides ÷ 8.56 + (triglycerides × non-HDL-C) ÷ 2140 − triglycerides² ÷ 16100] − 9.44. The original NIH equation study specifies triglycerides up to and including 800 mg/dL. Above that, the Sampson result is unavailable. If either formula returns a negative value, the calculator marks that estimate unavailable. A calculated zero remains zero. If a formula estimates more LDL-C than non-HDL-C, the ledger flags the discrepancy.
For mg/dL to mmol/L conversions, multiply cholesterol measures by 0.02586 and triglycerides by 0.01129. Divide by the applicable factor to convert back. Editable readings accept non-negative plain decimals with up to six decimal places and a maximum equivalent to 10,000 mg/dL. Total cholesterol must be positive and at least as large as HDL-C. These are software input limits. Unusual combinations can still produce estimates with limited clinical meaning.
Panels use readings from one specimen each, with optional lab-reported LDL-C. A lab may report a measured value or an estimate from its own equation. Copy the value and method from your report when comparing. The display generally rounds to whole mg/dL or hundredths of mmol/L. The calculator keeps the original input behind unit changes and uses unrounded values to test eligibility and compute differences. Extra digits in the CSV support reproduction of the calculation. The worksheet compares concentrations and formula outputs. Clinical interpretation depends on the laboratory and the patient's context.Worked Example
If you input:
- Concentration unit: mg/dL
- Panel A Total cholesterol: 200 mg/dL
- Panel A HDL-C: 50 mg/dL
- Panel A Triglycerides: 150 mg/dL
- Panel A Lab-reported LDL-C (optional): 125 mg/dL
Result:
Non-HDL-C is 200 − 50 = 150 mg/dL. Friedewald gives 150 − 150 ÷ 5 = 120 mg/dL. Substituting the same readings into the Sampson equation gives about 123.4 mg/dL, displayed as 123 mg/dL. The lab-reported 125 mg/dL is shown in its own row.
Frequently Asked Questions
Why do the calculated LDL-C values differ?
Friedewald uses a fixed triglyceride factor to approximate one cholesterol component. The Sampson equation adjusts for both triglycerides and non-HDL-C. Each equation estimates LDL-C and can differ from the lab's measurement or calculation.
Why is my Friedewald estimate unavailable?
The calculator uses Friedewald for triglycerides below 400 mg/dL. At 400 mg/dL or above the Friedewald row gives the range reason. An equation that computes a negative concentration also shows unavailable.
Can I enter triglycerides above 800 mg/dL?
You can record the panel and review its non-HDL-C and any LDL-C printed by your lab. Both formulas show unavailable because the triglyceride value exceeds their stated ranges here.
What is non-HDL cholesterol?
Non-HDL-C is total cholesterol minus HDL-C. It covers cholesterol carried by all the particles outside HDL-C. It therefore has its own row alongside the specific LDL-C measures.
Why is a difference unavailable even though I entered two panels?
A difference uses the same measure in both panels. For example, if one panel falls outside the Friedewald range, that row cannot compare Friedewald results across the two panels.
What should I enter after switching units?
Use the newly selected unit for new edits. The visible values for previous entries are conversions, and the calculator keeps those original quantities until you edit them. Cholesterol and triglycerides use different conversion factors.
Similar Calculators
A1C Calculator & Lab History
Compare dated lab A1C results in NGSP percent and IFCC mmol/mol. Plot your history, calculate ADAG estimated average glucose, and export the original readings.
Osmolality Calculator
Estimate serum osmolality from sodium, glucose, BUN, and optional ethanol.
Uncertainty Propagation Calculator
Propagate independent measurement uncertainties through sums, products and ratios. Compare contributions, expanded uncertainty and input improvement scenarios.