Forklift Capacity & Load Center Audit

Reconcile a measured cargo manifest and two current forklift capacity rows. Inspect how each item contributes to the longitudinal load center, check if that interval and the requested lift height are covered by the recorded row, and compare mass only where the row applies.

Measured cargo and nameplates

Check recorded forklift capacity rows

Edit cargo measurements and documented rows

One per line. Enter label, kg, longitudinal center in mm from the common cargo datum.

Match the configuration and reference on the current documentation. Enter a documented point as both endpoints. A positive placement moves the cargo datum farther from the row reference.

Configuration A
Configuration B

Configuration A is within its recorded row. Configuration B has partial row coverage.

Measured cargo 2,100 kg · Cargo-datum center 600 mm

Configuration A

Within recorded row values

Measured load-center interval

615 to 625 mm

Recorded center band 600 to 625 mm

Height 3,500 mm · within recorded height interval

On the listed mass limit

Configuration B

Partial load-center coverage

Measured load-center interval

625 to 635 mm

Recorded center band 600 to 625 mm

Height 3,500 mm · within recorded height interval

Mass comparison unavailable for this row

This desk comparison covers the entered longitudinal measurements. Use the actual equipment documentation and trained operators for a lift decision.

Inspect the longitudinal load center

Item centers from the row reference

0 mm860 mm
  • Selected item
  • Combined center
  • Row reference

Close-up of load-center coverage

Recorded row
600 to 625 mm
Measured interval
615 to 625 mm

Entire load-center interval covered

Front crate · 1,100 kg

Combined center 620 mm

Item center 420 mm from row reference

Item moment 462,000 kg-mm

Review the exact cargo and row ledger
Exact cargo positions and nameplate checks
ConfigurationItemMass kgCargo datum mmRow datum mmMoment kg-mmRow status
AFront crate1100400420462000Within recorded row values
ARear crate900840860774000Within recorded row values
APallet10064066066000Within recorded row values
BFront crate1100400430473000Partial load-center coverage
BRear crate900840870783000Partial load-center coverage
BPallet10064067067000Partial load-center coverage

How to use this calculator

  1. Enter each carried item’s measured mass and longitudinal center station relative to the same cargo datum.
  2. For each configuration, transcribe one applicable current row and its documented limits. Enter the planned geometry as data, using the same load-center reference as the row.
  3. Enter the signed placement offset, its uncertainty and requested lift height. Repeat a single documented load center as both limits.
  4. Compare recorded coverage, inspect item contributions and review any difference between measured mass and the listed value where the row applies.
  5. Open the exact ledger or download the values for a documentation review.

The Formula

The mathematical logic powering this calculation is:

For each item with measured mass m and longitudinal center station s measured from one cargo datum, its cargo-datum moment is m × s. Total mass M is the sum of the item masses. The combined longitudinal center is the sum of moments divided by M. The worksheet uses entered item centers, including any pallet or packaging carried with the load. An item’s external midpoint can differ from its measured center of gravity.
For each configuration, use the actual load-center reference specified by its documented row. Add the signed cargo-datum placement offset to every item station and to the combined center. The entered placement uncertainty expands the combined center by the same amount in each direction. It represents uncertainty in the common offset only. Item weights, component centers, and lift height are treated as entered points.
Compare the closed height and load-center bounds you transcribed for the exact truck, attachment and configuration. When the manufacturer provides one applicable point only, enter it as both endpoints. A partially overlapping center interval is marked partial. A disjoint interval or a height outside the row is marked outside. When the entire center interval and the entered height are covered, recorded mass margin equals listed capacity minus measured total mass. Equality counts in the arithmetic check. The listed capacity is transcribed, with no interpolation or estimated capacity outside its domain.
This is a longitudinal desk calculation on transcribed values. Actual operation and stability depend on the current equipment documentation, trained operators and additional factors including lateral and vertical center of gravity, securement, attachment and site conditions. Example entries are arithmetic demonstrations. Inputs support 1–10 items, mass or capacity above zero through 1,000,000 kg, distances through 100,000 mm, signed placement, and three decimal places. Arithmetic and CSV fractions are exact.

Worked Example

If you input:

  • Cargo: 1,100 kg at 400 mm, 900 kg at 840 mm and 100 kg at 640 mm
  • Both transcribed rows: 600–625 mm load-center band and 0–3,500 mm lift band
  • Configuration A: 20 ± 5 mm placement offset, 3,500 mm height, 2,100 kg listed capacity
  • Configuration B: 30 ± 5 mm placement offset, 3,500 mm height, 2,500 kg listed capacity

Result:

The shared mass is 2,100 kg and the cargo-datum center is 600 mm. Configuration A spans 615–625 mm and is exactly on the recorded mass and height limits. Configuration B spans 625–635 mm. It touches the recorded center band at one endpoint, so its mass margin is unavailable.

Frequently Asked Questions

Where do I measure the load center from?

Use the longitudinal reference named in that specific data plate or manufacturer chart. For many counterbalanced trucks, it is the vertical face of the forks. An attachment or different equipment configuration can change the applicable row or reference.

Why do I enter a minimum and maximum rather than one center?

The worksheet accepts only the applicability the equipment documentation supplies. Enter the same value twice for a single point, or enter the documented endpoints of a band.

Why does a partial match have no mass margin?

The recorded capacity only belongs to its documented configuration and domain. If some of the entered center interval or the height is outside it, the worksheet leaves the margin blank.

Does this compare dynamic stability or provide a new capacity rating?

The calculation compares measured longitudinal values with transcribed row limits. Trained operators use the current manufacturer documentation for operation and stability.