Extrusion Flow Coupon Mass Calculator

Use two separately printed coupons per profile at each matched flow. Enter the reference mass, allowed deviation, and your weighing allowance. The worksheet keeps every pass, outside-band reading, and unresolved interval visible.

Matched extrusion tests

Compare extrusion flow using weighed print coupons

Find which measured rates meet your coupon mass band and where the uninterrupted passing run ends.

Reference mass and matched tests

Use the same reference for both profiles.

Symmetric around the reference.

Applied to each reading independently.

Enter 3–12 lines. Each line is achieved flow (mm³/s), two profile A coupon masses (g), and two profile B coupon masses (g), separated by commas or tabs.

Passing readings reappear after a non-passing rate.

Passing tested rates by profile

Accepted mass band 4.9 to 5.1 g

Profile A

Highest passing tested rate
16 mm³/s
Passing prefix through
8 mm³/s

1 later pass

Profile B

Highest passing tested rate
20 mm³/s
Passing prefix through
12 mm³/s

1 later pass

The passing prefix starts at the lowest tested flow and ends before the first unresolved or outside-band result.

12 mm³/s · Unresolved

Coupon 1
4.9 g
4.88 to 4.92 g
Coupon 2
4.91 g
4.89 to 4.93 g
Coupon masses across tested flow rates
Two coupon mass intervals per tested rateProfile A. The acceptable coupon mass is 4.9 to 5.1 grams. The selected rate is 12 cubic millimeters per second. Unresolved.Coupon mass (g)Lowest rateHighest rate

Each circle is a weighed coupon. Whiskers show its entered weighing allowance. The green band shows acceptable mass. Open marks below the axis show passes after earlier non-passes.

All classifications for profile A
  • 4 mm³/s · Pass
  • 8 mm³/s · Pass
  • 12 mm³/s · Unresolved
  • 16 mm³/s · Pass · Pass after non-pass
  • 20 mm³/s · Outside band

Coupon mass checks material delivered at these tested settings. Use separate tests for strength, adhesion, and dimensional quality.

Export the coupon mass audit

The CSV records both profiles, exact mass intervals, and every classification.

View CSV text

How to use this calculator

  1. Enter the common coupon reference mass, percentage tolerance, and per-reading weighing allowance.
  2. For each achieved flow rate, enter the two profile A coupon masses and two profile B coupon masses in grams.
  3. Read each profile’s highest passing rate and the passing sequence beginning at its lowest test. Compare which later passes follow a break.
  4. Choose the chart profile, inspect individual mass intervals, and export all classifications.

The Formula

The mathematical logic powering this calculation is:

Let the reference coupon mass be M and entered symmetric tolerance be p percent. The inclusive band is [M(1 − p/100), M(1 + p/100)]. Each measured mass m has its own interval [max(0, m − u), m + u], where u is the supplied weighing allowance in grams. Use an allowance applicable to the measuring procedure. Two coupon readings do not establish the uncertainty of a balance or characterize process variation.

A tested rate passes when both entire mass intervals fit inside the band. It is outside the band when either mass interval is disjoint from the band. The remaining cases are unresolved. Exact contact from the inside qualifies. An interval that approaches the band from outside and only touches its boundary is unresolved.

Sort the matched rates from low to high for both profiles. The highest passing tested rate is the largest entered rate with a pass. The passing prefix is the uninterrupted sequence of passes beginning at the lowest tested rate. Both unresolved and outside-band results end that sequence. An isolated later pass stays visible and does not extend the prefix. The calculator checks recorded points and makes no inference between rates.

Use 3–12 matched distinct achieved rates, in mm³/s, with two separately printed and weighed coupons for each profile at each rate. Compare identical coupon geometry and the same reference definition. Control or record differences in material, path, cooling, and other settings that could change deposited mass. Use achieved rates consistent with the test because a volumetric cap or other speed limits can make achieved and requested settings differ. Mass and rate are positive up to 1,000, tolerance is 0–100%, and allowance is 0–1,000 g. Inputs use up to six decimal places. The arithmetic checks material delivery. Strength, bonding, and dimensions need separate tests.

Worked Example

If you input:

  • Reference: 5 g
  • Allowed band: ±2%
  • Weighing allowance: 0.02 g per reading
  • Tested rates: 4, 8, 12, 16, 20 mm³/s

Result:

Profile A passes through 8 mm³/s, has an unresolved result at 12, and passes again at 16. Profile B passes through 12, is outside the band at 16, and passes again at 20.

Frequently Asked Questions

What does the passing prefix show?

It passes every entered test starting at the lowest rate. A later good point after an unresolved or outside-band result still counts as an individual pass.

What if the average mass is inside the band?

The worksheet checks each coupon’s interval separately. One low and one high reading can average near the target while either coupon misses the band.

Does a mass pass confirm print strength?

It confirms that the two recorded mass intervals fit the band. Dimensional accuracy, surface finish, and bonding require their own evidence.

Can I use the slicer's requested flow?

Use the achieved flow rate relevant to the coupon. Requested speeds may be reduced by volumetric settings, cooling, or other limits.