Crown Molding Calculator & Installation Quote

Enter measured wall corners and finished pieces for a single crown molding job. Compare two profile spring angles and two suppliers’ usable stock lengths. See each corner’s flat-cut angle magnitudes, the minimum number of full sticks and the entered installed price.

Trim project

Compare crown molding cuts and installation quotes

Check whether the entered profile angles and unspliced stock lengths fit the same job.

Quote B is $18.58 lower.

Finished piece lengths
Included wall angles
Supplier profiles, thresholds and prices
Quote A
Quote B
Quote A total
$339.08
2 sticks · all corner magnitudes within limits
Quote B total
$320.50
3 sticks · all corner magnitudes within limits

Corner angles and entered thresholds

Quote A

Miter 31.62° · bevel 33.86°

Within both entered limits

Quote B

Miter 35.26° · bevel 30°

Within both entered limits

Circles show Quote A and squares show Quote B. The filled markers identify the selected corner. Each dashed box shows that quote’s two entered limits.

Minimum whole-stick layouts

Each segment includes the 1 in rough reserve. The gray remainder is usable stock left over.

Quote A · 192 in sticks

Stick 1 · pieces 1 + 3 · 0 in left

Stick 2 · pieces 2 + 4 · 6 in left

Quote B · 144 in sticks

Stick 1 · pieces 1 · 25 in left

Stick 2 · pieces 2 · 29 in left

Stick 3 · pieces 3 + 4 · 0 in left

Entered installed cost

Quote A

Material
$130.00
Labor
$109.08
Fixed charges
$100.00

Quote B

Material
$162.00
Labor
$93.50
Fixed charges
$65.00
Full corner ledger and CSV
  • Corner 1 · 90°
    Quote A · 31.62° miter, 33.86° bevel · Within entered limits
    Quote B · 35.26° miter, 30° bevel · Within entered limits
  • Corner 2 · 92°
    Quote A · 30.73° miter, 33.19° bevel · Within entered limits
    Quote B · 34.33° miter, 29.42° bevel · Within entered limits
  • Corner 3 · 88°
    Quote A · 32.52° miter, 34.53° bevel · Within entered limits
    Quote B · 36.21° miter, 30.57° bevel · Within entered limits

How to use this calculator

  1. Enter measured finished pieces in inches and the total rough cut reserve per piece.
  2. Add one row per checked wall corner. Enter the smaller included angle at each turn.
  3. Enter each profile’s spring, usable stock and written miter and bevel thresholds for comparison.
  4. Copy each installation rate and charge into its own quote. Confirm you are comparing the same work.
  5. Review the cut setting plot, unspliced cut plan and exact quote ledger. Download the audit to retain your assumptions.

The Formula

The mathematical logic powering this calculation is:

Use the smaller included wall angle C between the two runs, which is 90° for a square inside or outside turn. Spring angle S is from the wall to the crown profile when installed between a level ceiling and a vertical wall. For the flat compound geometry, miter magnitude = atan2(sin(S) × cos(C/2), sin(C/2)); bevel magnitude = asin(cos(S) × cos(C/2)). Trigonometry uses radians internally and returns degrees. The diagram compares magnitudes. Left/right orientation and safe capacity for simultaneous settings depend on the saw, cut side, fixture and profile. Use the manufacturer’s directions for those choices. The worksheet checks the two entered magnitude limits separately at 0.0000000001° numerical tolerance.

For each finished piece add its entered shared reserve once. Choose the reserve to account for the actual toe, end trim and kerf convention used in your rough cut plan. Each piece uses one unspliced stick segment. The solver tests feasible assignments of these measured lengths up to eight pieces and selects the smallest number of the entered usable sticks. Leftover is usable stick length less the sum of assigned rough lengths. Enter usable length after any stock damage or end loss that applies to the whole stick.

Material uses whole sticks times the entered price per stick. Installation labor uses the sum of finished inches divided by 12 times the entered per-foot rate, then rounds half a cent upward. Add the entered fixed fee for the total. Enter combined fixed charges such as corners, finishing and fees once. Comparable ranking requires confirmed scope, sufficient entered stock length and both angle magnitudes within their own limits. Treat the two thresholds as a screen for the values you entered.

Enter one to eight finished piece lengths, one to six measured corners and a reserve from 0 to 40 in per piece, all with up to two decimals. Finished and usable stock both span 1–480 in. Corners span 30°–180°, springs 1°–89° and the two limits 0°–90°. USD prices use two decimals through $1 million per field.

Worked Example

If you input:

  • Finished pieces: 118, 114, 72 and 70 in
  • Reserve: 1 in per piece
  • Wall corners: 90°, 92°, 88°
  • Quote A: 38° spring, 192-in usable sticks at $65 each, $3.50/ft labor and $100 fixed
  • Quote B: 45° spring, 144-in usable sticks at $54 each, $3/ft labor and $65 fixed

Result:

All three corners fit the two entered 45° magnitude limits for both profiles. Quote A uses two sticks and totals $339.08. Quote B uses three sticks and totals $320.50, which is $18.58 less.

Frequently Asked Questions

Is spring angle measured from the wall or from the ceiling?

Enter the profile’s wall spring angle. The other angle in a crown profile marked 38°/52° is its complement against a level ceiling.

What miter and bevel magnitudes should I see for a square wall?

A 38° spring in a 90° corner gives about 31.62° miter and 33.86° bevel. A 45° spring gives about 35.26° and 30.00°, respectively.

Why enter a usable stock length?

Available lengths may differ from nominal lengths. The usable stick value is what the listed rough pieces may use after excluding your whole-stick end trim or defects.

How do I account for kerf, profile toe and scribing?

Add the necessary amount once in the shared rough cut reserve per piece. Review each finished length separately if a piece needs extra allowance.

How does the calculator reuse offcuts?

All rough pieces of a single quote’s profile are pooled. Each piece fits on one stick, and the assignment uses the fewest sticks that fit those pieces.

Why can a lower quote remain unranked?

An entered stock or angle limit can rule out a layout, or the rate scopes can differ. The inputs, geometry and available receipt remain visible for review.

Similar Calculators