Crossed Gage R&R Calculator

Enter measurements where each operator measures every part the same number of times. Separate within-pair repeatability, operator variation, part-by-operator variation, and part differences using the full random-effects crossed ANOVA. Check your chosen share of specification tolerance and trace the raw and nonnegative variance estimates.

Measurement system analysis

Measure crossed gage variation

Use uppercase part ID | operator ID | readings separated by commas. Enter every pair and the same number of readings per row.

Gage variation exactly meets the entered tolerance share.

Study spread as share of width
10%
Entered target 10%
Minimum width at target
60
In the entered measurement units
Balanced design
2 × 2 × 2
Parts × operators × repeats

What contributes to gage variance?

Bars show each source’s share of the combined gage variance. Part-to-part variation is reported separately.

Repeatability

50% of gage variance

Used variance 1/2

Part by operator

0% of gage variance

Used variance 0

Operators

50% of gage variance

Used variance 1/2

Part-to-part variance 50. Total modeled variance 51.

Review the exact ANOVA audit

Show mean squares and variance components

Negative raw components contribute zero to the combined variance.

  • Repeatability

    4 degrees of freedom · SS 2

    MS 1/2

    Raw variance 1/2 · Used variance 1/2

  • Part by operator

    1 degrees of freedom · SS 0

    MS 0

    Raw variance -1/4 · Used variance 0

  • Operators

    1 degrees of freedom · SS 2

    MS 2

    Raw variance 1/2 · Used variance 1/2

  • Parts

    1 degrees of freedom · SS 200

    MS 200

    Raw variance 50 · Used variance 50

How to use this calculator

  1. Enter the specification width and the largest acceptable percent of that width for study spread.
  2. Enter one row per part and operator pair as part ID | operator ID | measurements separated by commas. Each pair must have the same repeat count.
  3. Compare the observed percent tolerance with the target and use the variance chart to identify the contributing components.
  4. Inspect the ANOVA table and download its exact fractions. Review negative raw estimates and the zero floor before interpreting the result.

The Formula

The mathematical logic powering this calculation is:

Use P parts, O operators and R repeats for every crossed pair. Partition corrected total sum of squares into parts, operators, pair interaction and within-pair error. For part effects, sum squared deviations of part means from the grand mean and multiply by OR. For operator effects, use PR. Within-pair error sums squared deviations of readings from their own pair mean. The remaining sum of squares belongs to interaction. Degrees of freedom are P−1, O−1, (P−1)(O−1), and PO(R−1), respectively. Each mean square is its sum of squares divided by degrees of freedom.
The full-model variance estimates are MS error for repeatability, (MS interaction−MS error)/R for interaction, (MS operator−MS interaction)/(PR) for operators, and (MS part−MS interaction)/(OR) for parts. Retain the raw values and replace negative estimates with zero when calculating combined variance. Gage R&R is the sum of the nonnegative repeatability, interaction and operator components. Total modeled variance adds the nonnegative part component.
Study spread is six times the square root of Gage R&R. Percent tolerance = 100 × spread/specification width. Compare variance directly to [width × entered percent/600]² for an exact threshold. The chart’s spread and required-width displays use approximate square roots. The model always keeps the interaction term. Unbalanced, nested, changing-scale or destructive studies need a different analysis.

Worked Example

If you input:

  • Design: 2 parts, 2 operators and 2 readings per pair
  • Width: 60 measurement units
  • Target: 10%

Result:

Repeatability and operator variance are each 0.5. The raw interaction estimate is −0.25 and the combined model uses zero for it. Gage variance is exactly 1, study spread is 6 and percent tolerance is exactly 10%.

Frequently Asked Questions

What makes this a crossed study?

Every operator measures each included part. All operator–part pairs have the same number of repeats.

Why can a raw variance estimate be negative?

A method-of-moments difference of mean squares can be negative in finite samples. The worksheet keeps that raw difference and uses zero for the combined nonnegative variation estimate.

Does the calculator remove an insignificant interaction?

The full two-way ANOVA always retains the interaction. Software configured to pool that term can give a different result on the same data.

Is percent tolerance the same as percent variance contribution?

Percent tolerance compares a width from the measurement system’s standard deviation with the entered specification width. Variance contribution compares squared variation components against their variance total.

Can the result certify a production gauge?

Use the worksheet with the organization’s documented study design and decision criteria. Repeatability, reproducibility and tolerance arithmetic is only part of a complete measurement-system assessment.

Similar Calculators