Aluminum Weight Calculator & Extrusion Mass Window

Compare two rectangular hollow profiles with the same outside dimensions, alloy density and cut list. Enter four wall thicknesses and a documented wall allowance for each profile. See the possible mass range, the cap result and the location of the metal centroid in selected sections.

Rectangular hollow aluminum

Compare aluminum extrusion mass ranges

Edit section dimensions, cut list and cap

The profiles share the outside size, cut list and density. Each thickness may vary independently by its profile’s allowance.

Profile A
Profile B

Only Profile A fits the full batch mass range.

Batch cap 17.77032 kg · 2 pieces of 5 m

Profile A

Entire mass range fits

Batch mass across the wall allowance

16.24752 to 17.77032 kg

Nominal mass per meter
1.701 kg/m
Margin at thickest walls
0 kg

Profile B

Part of the mass range fits

Batch mass across the wall allowance

16.7616 to 18.28224 kg

Nominal mass per meter
1.7523 kg/m
Margin at thickest walls
-0.51192 kg

Compare batch mass with the limit

Profile AProfile B
15.973 kg18.556 kg

Entered cap 17.77032 kg

Inspect a hollow cross section

Outer walls, opening and metal centroid

  • Metal
  • Outside centerlines
  • Metal centroid

Profile A · Nominal walls

Opening 95 × 46 mm

Net section 630 mm²

Centroid 46.53174603 mm from left, 25 mm from bottom

Batch 17.01 kg · At or below cap

Review the exact extrusion ledger
Exact hollow section and mass data
Profile and stateOpening width (mm)Opening height (mm)Net area (mm²)Centroid X (mm)Centroid Y (mm)Batch (kg)
A · Thinnest walls476/5231/515044/25348611/752225101547/6250
A · Nominal walls95466305863/126251701/100
A · Thickest walls474/5229/516454/25768427/1645425222129/12500
B · Thinnest walls476/5463104/5502510476/625
B · Nominal walls95229/5649502517523/1000
B · Thickest walls474/5228/516928/25502557132/3125

How to use this calculator

  1. Enter the shared fixed outside width and height, cut length per piece and whole piece count.
  2. Enter the documented alloy density and the batch mass limit.
  3. Copy nominal wall measurements for all four sides and an applicable allowance for each profile.
  4. Compare the entire batch mass range and select a cross section to inspect the opening and centroid.
  5. Review or download the exact profile quantities.

The Formula

The mathematical logic powering this calculation is:

Use one outside width W and height H. For a rectangular cross section with square corners, clear opening width is W − left wall − right wall. Clear opening height is H − bottom wall − top wall. Net metal area equals outside rectangle area minus opening area. Mass per meter in kg/m equals net area in mm² times density in kg/m³ divided by 1,000,000. Multiply by cut length in meters for piece mass and by the whole piece count for batch mass.

For each profile, every wall can independently vary from its entered thickness minus the profile’s allowance to its thickness plus that allowance. Both extreme sections must preserve positive walls and a positive clear opening. With outside dimensions fixed, the net area increases when any wall becomes thicker. All four low wall values give the exact minimum mass and all four high wall values give the maximum. Equal mass and cap counts as meeting the cap. The thinnest, nominal and thickest modeled states are inspectable on the same section scale.

The metal centroid uses first moments about the bottom-left outside corner. Subtract opening area times its coordinate from outside area times the outside center coordinate, then divide by net metal area. The diagram and export report centroids of the three shown sections. Those coordinates are not the bounds of a centroid tolerance interval.

Enter positive outside dimensions and nominal walls through 10,000 mm, an allowance of 0–10,000 mm, density 100–30,000 kg/m³, cut length 0.000001–1,000 m, 1–1,000,000 whole pieces, and a batch cap of 0–1,000,000,000 kg. Decimal fields take up to six places. The mass calculation assumes uniform material density, sharp corners and one constant section per piece. Catalog radii, local wall variation along the length, finish, machining features and hardware can change actual mass. Use documented material data and measurements.

Worked Example

If you input:

  • Outside section: 100 × 50 mm
  • Cut list and density: Two 5 m pieces, 2,700 kg/m³
  • Profile A: Left/right 3/2 mm, bottom/top 2/2 mm, ±0.1 mm
  • Profile B: Left/right 2.5/2.5 mm, bottom/top 2.1/2.1 mm, ±0.1 mm
  • Entered batch limit: 17.77032 kg

Result:

A ranges from 16.24752 to 17.77032 kg and meets the limit at its maximum. B ranges from 16.7616 to 18.28224 kg and spans the limit. A’s nominal centroid lies left of the outside center because its opening is offset to the right.

Frequently Asked Questions

Why enter the four walls separately?

Unequal opposing walls shift the opening. The surrounding metal’s centroid moves toward the thicker wall, even when the outer dimensions stay fixed.

Why do the thinnest and thickest cases bound mass?

Each wall eats into the fixed clear opening as it grows. With a positive rectangular opening, increasing any wall increases metal area.

Can I enter exact measured walls without an allowance?

Yes. An allowance of zero gives one mass repeated across the modeled states.

Why can the catalog kg/m differ from this result?

The modeled section uses sharp corners, a fixed outside envelope and the entered density. Catalog parts can use radii, coating and different measurement or rounding conventions.

Do the three shown centroids bound where the centroid can fall?

They give the values for the three displayed sections. Mixed choices of wall minima and maxima can produce different centroid positions.

What weight convention does this worksheet use?

It reports mass in kilograms. Force and member strength require their own calculations.