Home Blood Pressure Average & Reading Log

Enter systolic and diastolic readings in a one- to seven-day log. Compare the mean of available readings with the first-day exclusion, review which morning and evening records are missing, and optionally check the recorded adult home monitoring schedule against the NICE schedule fields.

Home reading worksheet

Average your recorded blood pressure readings

Compare the typed readings with and without the opening day. Review missing repeats and keep their chronology alongside the averages.

Calendar and averaging choice

The examples use illustrative readings. Use the date buttons to edit your log.

Averages and session counts

NICE schedule check

123.0 / 77.0 mmHg

12 of 16 recorded pairs included.

Opening date excluded · 2026-10-05

Recorded NICE schedule complete.

Days with four readings
4 of 4
Sessions missing a repeat
0 of 8
Full sessions with unmet or unrecorded conditions
0

This check covers the entered schedule and your recorded repeat conditions.

Descriptive comparisons

All readings · 16 pairs
125.5 / 78.5 mmHg
After opening date · 12 pairs
123.0 / 77.0 mmHg

These descriptive means use available pairs regardless of schedule completeness.

Morning and evening readings

Day 1 · 2026-10-05

Leave both cells empty for a missing reading. In each session, Met means both consecutive readings were seated and at least one minute apart.

Morning session

Reading 1

Reading 2

Evening session

Reading 1

Reading 2

Daily readings over time

Observed daily means · 71.1 to 136.9 mmHg. Missing dates leave gaps.

The outlined opening-day markers are excluded from the selected method.

Daily systolic and diastolic means by dateCircles represent systolic observations and squares represent diastolic observations in mmHg. The opening date is separated from the selected average. The date ledger lists the corresponding recorded values.
2026-10-052026-10-08
  • Systolic
  • Diastolic

Reading ledger and export

Each row shows the two readings for a morning or evening session and the entry for its repeat conditions.

Open session ledger
Home readings in mmHg and selected average use
Date and sessionReading 1Reading 2Repeat conditionsDaily meanSelected use
2026-10-05 · Morning134 / 84132 / 82Met133.0 / 83.0Opening day excluded
2026-10-05 · Evening130 / 80136 / 86Met133.0 / 83.0Opening day excluded
2026-10-06 · Morning124 / 78120 / 74Met123.0 / 77.0Counts when entered
2026-10-06 · Evening122 / 76126 / 80Met123.0 / 77.0Counts when entered
2026-10-07 · Morning118 / 72122 / 76Met121.0 / 75.0Counts when entered
2026-10-07 · Evening124 / 78120 / 74Met121.0 / 75.0Counts when entered
2026-10-08 · Morning126 / 80128 / 82Met125.0 / 79.0Counts when entered
2026-10-08 · Evening124 / 78122 / 76Met125.0 / 79.0Counts when entered
Download reading log CSV
Open CSV text

How to use this calculator

  1. Choose the first calendar date and the number of consecutive dates you want in the log.
  2. Open each date and enter the systolic and diastolic values for every morning or evening reading. Leave both fields blank for a reading you did not take.
  3. If using the NICE schedule check, record each session’s repeat conditions, including the first day.
  4. Compare the selected average and denominator. Review the date chart and the session ledger, then download the readings if you want a copy.

The Formula

The mathematical logic powering this calculation is:

For any selected set of paired readings, add the systolic values and divide by the number of pairs. Do the same with the diastolic values using that same count. Every whole reading pair has equal weight. A day with three readings therefore contributes three terms to each sum, while a day with one contributes one. Day and session means follow the same rule within their own readings. A fully blank slot is missing, and a half-entered or malformed reading needs correction before the worksheet can calculate. The chart shows the observed mean on each date with at least one reading. It leaves gaps where there were no entries.

All readings uses every available whole pair in the chosen window. Skip first day removes the opening calendar date from the average, even when it was blank. Both are descriptive averages. They use actual entered observations and do not imply completion of a home measurement schedule.

NICE NG136 recommendation 1.2.7 describes two consecutive readings at least one minute apart while seated at each of two daily sessions, typically morning and evening, for at least four days and preferably seven. It excludes the opening day's measurements when averaging. In the NICE schedule check view, this worksheet shows a selected average only when at least four consecutive logged dates each have both complete morning and evening repeats and every session has its repeat conditions marked Met, including the opening day. It then counts only the remaining dates. The check covers the entered schedule and user-reported repeat conditions. It cannot verify the device, technique or clinical meaning.

Enter dates in years 1900 through 2200 and choose 1 to 7 consecutive dates. Systolic and diastolic accept 0.1 to 999.9 mmHg with one decimal as a worksheet input range. Values are averaged as entered, without classifying or filtering them using medical thresholds. Displayed averages are rounded to one decimal. The CSV includes the recorded readings, the counts and the applied selection. The worksheet requests no names or other identifying details.

Worked Example

If you input:

  • Calendar window: 2026-10-05 through 2026-10-08.
  • Readings per date: Two morning and two evening pairs, with repeat conditions marked Met for all sessions.
  • Day averages: 133.0 / 83.0, 123.0 / 77.0, 121.0 / 75.0 and 125.0 / 79.0 mmHg.

Result:

The NICE schedule check uses 12 pairs after excluding the opening date. Their average is 123.0 / 77.0 mmHg. The All readings view uses 16 pairs, averaging 125.5 / 78.5 mmHg. These are illustrative observations.

Frequently Asked Questions

How is an average calculated when there are uneven numbers of readings per day?

The worksheet sums each component across all selected individual reading pairs. Each pair contributes once, so a date with more readings contributes more to the pooled mean.

Which day does Skip first day remove?

It removes the opening calendar date of the chosen window. If that date is blank, there are no readings to remove.

Why is the NICE schedule average unavailable?

The selected window needs at least four consecutive dates, two readings in both daily sessions, and Met repeat conditions recorded for every session. The log can still show entered observations and a separate descriptive average.

Can I leave a reading blank?

Leave both parts blank if the reading is missing. Enter both parts for a recorded reading. A half-entered pair remains editable and needs correction before an average is shown.

Why can the chart show a first-day point when it is excluded?

The timeline preserves the observed daily mean. When the active method excludes the first date, its markers are outlined and the chart labels the exclusion.

Does the worksheet interpret my readings?

The worksheet reports means, counts and recorded schedule completeness. Share the actual readings with your care team for clinical interpretation.

Similar Calculators