Gutter Slope Calculator & Measured Fall Survey

Compare each measured gutter span with the entered fall target in its assigned outlet direction. See whether a measured rise, drop or uncertain reading is hiding behind an end-to-end average that meets the same target.

Gutter fall survey

Check measured gutter slope and local fall

Outlet layout and review settings

Recorded gutter bottom elevations

Use horizontal positions increasing from left to right and elevations from the same datum.

Station 1
Station 2
Station 3
Station 4
At least one measured span falls away from its assigned outlet.
Spans meeting entered fall
2 of 3
Definitely reverse
1
Upper bound below zero in the assigned direction

Surveyed gutter profile and span checks

Station markers use the entered gutter-bottom elevation. The outlined rings mark the assigned outlets.

0.9751.52.0250 ft30 ftElevation (in)
Station 2 toward station 3 · Definitely reverse

-0.1 in nominal fall · -0.15 to -0.05 in with tolerance

Required fall 0.25 in over 10 ft

End-to-end paths

The endpoint comparison can pass even when a nearby measured span falls short.

  • Station 1 to outlet 4
    1 in nominal over 30 ft
    0.95 to 1.05 in with tolerance · Meets entered fall
Review exact fall measurements and CSV
  • Span 1 · Meets entered fall
    Exact nominal fall 3/10 in
    Exact fall limits 1/4 to 7/20 in
  • Span 2 · Definitely reverse
    Exact nominal fall -1/10 in
    Exact fall limits -3/20 to -1/20 in
  • Span 3 · Meets entered fall
    Exact nominal fall 4/5 in
    Exact fall limits 3/4 to 17/20 in

How to use this calculator

  1. Choose the observed end outlet or both end outlets and an identified interior split.
  2. Enter the applicable fall target and the known bounded elevation reading tolerance.
  3. Enter measured positions and bottom elevations relative to the same datum, ordered from left to right.
  4. Inspect local spans and end-to-end paths separately. Export the exact survey ledger.

The Formula

The mathematical logic powering this calculation is:

Use measured positions along one straight run, ordered from left to right. Enter each measured gutter-bottom elevation in inches above or below a common datum. Enter the outlet at one end, or choose both ends and identify an interior survey station as the intended split. Each span is assigned toward its entered outlet. The worksheet does not select a split or rearrange the measured stations.
For a directed span, subtract the measured elevation nearer its outlet from the upstream elevation. A positive number indicates a drop toward that outlet. Divide by the horizontal span length in feet and multiply by 10 for inches of fall per 10 ft. Required drop equals the entered target times span feet ÷ 10.
For an independent bounded reading error e at each station, the range for their difference is nominal drop ± 2e. This models a worst-case bound. A common vertical datum offset cancels. The whole-path range uses only its endpoints. A span meets the entered target when its lower bound reaches the required drop. It is definitely reverse if the upper bound is below zero. With the upper bound below a positive target and still at or above zero, it falls short. Other spans are unresolved at the entered tolerance.
Use two to twelve stations, distances from 0 to 5,000 ft, elevations from −10,000 to +10,000 in relative to the datum, a reading bound of 0–12 in and a target of 0–60 in per 10 ft. Values accept six decimals. Position uncertainties and geometry between records are outside this model. The profile connects measured points to show their relationship. It does not measure unobserved dips, infer water flow, approve an installation or supply a universal fall requirement. Use the actual product and agreed project requirements for the entered target.

Worked Example

If you input:

  • Stations: 0, 10, 20 and 30 ft with bottom elevations of 2.0, 1.7, 1.8 and 1.0 in.
  • Assigned outlet: Right end with a target of 0.25 in per 10 ft.
  • Reading bound: ±0.025 in per station.

Result:

The full 30 ft path nominally drops 1.00 in and meets the entered 0.75 in target. The middle span rises 0.10 in toward the outlet and remains reverse across its entered uncertainty.

Frequently Asked Questions

Can the end-to-end fall pass even though a section rises?

Yes. The net endpoint difference can hide a local rise. The worksheet checks each consecutive measured span independently.

What if the difference is exactly on the target?

The lower bound can equal the target and still meet it. When only the upper bound reaches the target, the span remains unresolved at that tolerance.

Does the profile show a dip between survey points?

The plot joins recorded positions. Additional measured stations help review local changes that the entered records do not capture.

Does a reverse result prove there will be standing water?

The result describes an uphill change in the assigned direction at the entered span and tolerance. Actual flow also depends on the full shape, outlet condition, obstructions and water depth.

Similar Calculators